Source author record

S. Badole

S. Badole appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

Sub-arcsecond imaging with the International LOFAR Telescope I. Foundational calibration strategy and pipeline

[abridged] The International LOFAR Telescope is an interferometer with stations spread across Europe. With baselines of up to ~2,000 km, LOFAR has the unique capability of achieving sub-arcsecond resolution at frequencies below 200 MHz, although this is technically and logistically challenging. Here we present a calibration strategy that builds on previous high-resolution work with LOFAR. We give an overview of the calibration strategy and discuss the special challenges inherent to enacting high-resolution imaging with LOFAR, and describe the pipeline, which is publicly available, in detail. We demonstrate the calibration strategy by using the pipeline on P205+55, a typical LOFAR Two-metre Sky Survey (LoTSS) pointing. We perform in-field delay calibration, solution referencing to other calibrators, self-calibration, and imaging of example directions of interest in the field. For this specific field and these ionospheric conditions, dispersive delay solutions can be transferred between calibrators up to ~1.5 degrees away, while phase solution transferral works well over 1 degree. We demonstrate a check of the astrometry and flux density scale. Imaging in 17 directions, the restoring beam is typically 0.3" x 0.2" although this varies slightly over the entire 5 square degree field of view. We achieve ~80 to 300 $μ$Jy/bm image rms noise, which is dependent on the distance from the phase centre; typical values are ~90 $μ$Jy/bm for the 8 hour observation with 48 MHz of bandwidth. Seventy percent of processed sources are detected, and from this we estimate that we should be able to image ~900 sources per LoTSS pointing. This equates to ~3 million sources in the northern sky, which LoTSS will entirely cover in the next several years. Future optimisation of the calibration strategy for efficient post-processing of LoTSS at high resolution (LoTSS-HR) makes this estimate a lower limit.

preprint2020arXiv

VLA and ALMA observations of the lensed radio-quiet quasar SDSS J0924+0219: a molecular structure in a 3 microJy radio source

We present Karl G. Jansky Very Large Array (VLA) and Atacama Large Millimetre Array (ALMA) observations of SDSS J0924+0219, a z = 1.524 radio-quiet lensed quasar with an intrinsic radio flux density of about 3 micro-Jy. The four lensed images are clearly detected in the radio continuum and the CO(5-4) line, whose centroid is at z = 1.5254 +/- 0.0001, with a marginal detection in the submillimetre continuum. The molecular gas displays ordered motion, in a structure approximately 1--2.5 kpc in physical extent, with typical velocities of 50-100 km/s. Our results are consistent with the radio emission being emitted from the same region, but not with a point source of radio emission. SDSS J0924+0219 shows an extreme anomaly in the flux ratios of the two merging images in the optical continuum and broad emission lines, suggesting the influence of microlensing by stars in the lensing galaxy. We find the flux ratio in the radio, submillimetre continuum and CO lines to be slightly greater than 1 but much less than that in the optical, which can be reproduced with a smooth galaxy mass model and an extended source. Our results, supported by a microlensing simulation, suggest that the most likely explanation for the optical flux anomaly is indeed microlensing.