Source author record

Sławomir Bilicki

Sławomir Bilicki appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Photoionization cross sections of ultracold $^{88}$Sr in $^1$P$_1$ and $^3$S$_1$ states at 390 nm and the resulting blue-detuned magic wavelength optical lattice clock constraints

We present the measurements of the photoionisation cross sections of the excited $^1$P$_1$ and $^3$S$_1$ states of ultracold $^{88}$Sr atoms at 389.889 nm wavelength, which is the magic wavelength of the $^{1}$S$_{0}$-${}^{3}$P${}_{0}$ clock transition. The photoionisation cross section of the $^1$P$_1$ state is determined from the measured ionisation rates of $^{88}$Sr in the magneto-optical trap in the $^1$P$_1$ state to be 2.20(50)$\times$10$^{-20}$ m$^2$, while the photoionisation cross section of $^{88}$Sr in the $^3$S$_1$ state is inferred from the photoionisation-induced reduction in the number of atoms transferred through the $^3\text{S}_1$ state in an operating optical lattice clock to be $1.38(66)\times$10$^{-18}$ m$^2$. Furthermore, the resulting limitations of employing a blue-detuned magic wavelength optical lattice in strontium optical lattice clocks are evaluated. We estimated photoionisation induced loss rates of atoms at 389.889 nm wavelength under typical experimental conditions and made several suggestions on how to mitigate these losses. In particular, the large photoionisation induced losses for the $^3$S$_1$ state would make the use of the $^3$S$_1$ state in the optical cycle in a blue-detuned optical lattice unfeasible and would instead require the less commonly used $^3$D$_{1,2}$ states during the detection part of the optical clock cycle.

preprint2016arXiv

Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock

Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a redefinition of the SI second based on optical clocks seems possible in the near future. However, the operation of optical lattice clocks has not yet reached the reliability that microwave clocks have achieved so far. In this paper, we report on the operation of a strontium optical lattice clock that spans several weeks, with more than 80% uptime. We make use of this long integration time to demonstrate a reproducible measurement of frequency ratios between the strontium clock transition and microwave Cs primary and Rb secondary frequency standards.