Researcher profile

Rugved Likhite

Rugved Likhite contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

Correcting Presbyopia with Autofocusing Liquid-Lens Eyeglasses

Presbyopia, an age-related ocular disorder, is characterized by the loss in the accommodative abilities of the human ocular system and afflicts more than 1.8 billion people world-wide. Conventional methods of correcting presbyopia fragment the field of vision, inherently resulting in significant vision impairment. We demonstrate the development, assembly and evaluation of autofocusing eyeglasses for restoration of accommodation without vision field loss. The adaptive optics eyeglasses consist of two variable-focus piezoelectric liquid lenses, a time-of-flight range sensor and low-power, dual microprocessor control electronics housed within an ergonomic frame. Patient-specific accommodation deficiency models were utilized to demonstrate a high-fidelity accommodative correction. Each accommodation correction calculation was performed in ~67 ms requiring 4.86 mJ of energy. The optical resolution of the system was 10.5 cycles/degree, featuring a restorative accommodative range of 4.3 D. This system can run for up to 19 hours between charge cycles and weighs ~132 g, allowing comfortable restoration of accommodative function

preprint2020arXiv

VOC Sensing Using Batch-fabricated Temperature Compensated Self-Leveling Microstructures

We present the design, fabrication, and response of a low-power, polymer-based VOC sensor based on the self-leveling of mechanically leveraged structures. The device utilizes folded polymer-coated microcantilevers to achieve passive temperature compensation without the need for additional compensating sensors or electronics. We demonstrate that a self-leveling vapor sensor provides the same gas response as a simple microcantilever geometry, showing ~20% change in device capacitance when subjected to 35-85 %RH change while showing nearly-zero baseline drift due to changes in ambient temperature when the temperature is increased from 23-72°C which is ~52-fold better than a simple microcantilever geometry. The response of the VOC sensor was measured using three polymers (Polyimide, Polyurethane, and PDMS) against five different analytes (Ethanol, Acetone, Benzene, Hexane, and Water) and an SVM-based model was used to show target specificity. The sensor also showed an absorption response time (τ90) of ~138s. We propose that the self-leveling vapor sensor geometry is a significant improvement to a simple microcantilever vapor sensor as it offers the same performance but shows near-complete elimination of temperature-induced baseline drift.