Researcher profile

Ross Callaghan

Ross Callaghan contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2026arXiv

When Brains Disagree: Biological Ambiguity Underlies the Challenge of Amyloid PET Synthesis from Structural MRI

Structural MRI-to-amyloid PET synthesis has been proposed as a non-invasive alternative for amyloid assessment in Alzheimer's disease (AD). However, reported performance of identical models varies widely across studies, and increasingly complex architectures have not led to consistent gains. This inconsistency is thought to be caused by a fundamental biological ambiguity: MRI captures neurodegeneration, while PET measures amyloid pathology - two processes that are often temporally decoupled in AD. As a result, similar MRI patterns may correspond to different amyloid states, creating ambiguous one-to-many mappings. MRI-to-amyloid PET synthesis may therefore be intrinsically ill-posed; however, this idea has yet to be tested scientifically. The aim of this work is to test this hypothesis through two controlled experiments. We first control the training distribution by stratifying paired MRI-PET data by amyloid and neurodegeneration status. Using two standard synthesis models under a controlled design, we show that biologically unambiguous mappings are learnable in isolation, but performance collapses when data ambiguity is introduced. This demonstrates that ambiguity in the data distribution, rather than architectural capacity, constrains performance. Second, we show that introducing orthogonal biological information in the form of plasma biomarkers resolves this ambiguity. When multimodal inputs are incorporated, performance improves and stability is restored. Together, these findings suggest that limited and inconsistent performance in MRI-to-amyloid PET synthesis is explained by intrinsic biological ambiguity, and that stable, meaningful progress requires multimodal integration rather than architectural complexity.

preprint2022arXiv

Impact of within-voxel heterogeneity in fibre geometry on spherical deconvolution

Axons in white matter have been shown to have varying geometries within a bundle using ex vivo imaging techniques, but what does this mean for diffusion MRI (dMRI) based spherical deconvolution (SD)? SD attempts to estimate the fibre orientation distribution function (fODF) by assuming a single dMRI fibre response function (FRF) for all white matter populations and deconvolving this FRF from the dMRI signal at each voxel to estimate the fODF. Variable fibre geometry within a bundle however suggests the FRF might not be constant even within a single voxel. We test what impact realistic fibre geometry has on SD by simulating the dMRI signal in a range of realistic white matter numerical phantoms, including synthetic phantoms and real axons segmented from electron microscopy. We demonstrate that variable fibre geometry leads to a variable FRF across axons and that in general no single FRF is effective to recover the underlying fibre orientation distribution function (fODF). This finding suggests that assuming a single FRF can lead to misestimation of the fODF, causing further downstream errors in techniques such as tractography.

preprint2020arXiv

ConFiG: Contextual Fibre Growth to generate realistic axonal packing for diffusion MRI simulation

This paper presents Contextual Fibre Growth (ConFiG), an approach to generate white matter numerical phantoms by mimicking natural fibre genesis. ConFiG grows fibres one-by-one, following simple rules motivated by real axonal guidance mechanisms. These simple rules enable ConFiG to generate phantoms with tuneable microstructural features by growing fibres while attempting to meet morphological targets such as user-specified density and orientation distribution. We compare ConFiG to the state-of-the-art approach based on packing fibres together by generating phantoms in a range of fibre configurations including crossing fibre bundles and orientation dispersion. Results demonstrate that ConFiG produces phantoms with up to 20% higher densities than the state-of-the-art, particularly in complex configurations with crossing fibres. We additionally show that the microstructural morphology of ConFiG phantoms is comparable to real tissue, producing diameter and orientation distributions close to electron microscopy estimates from real tissue as well as capturing complex fibre cross sections. Signals simulated from ConFiG phantoms match real diffusion MRI data well, showing that ConFiG phantoms can be used to generate realistic diffusion MRI data. This demonstrates the feasibility of ConFiG to generate realistic synthetic diffusion MRI data for developing and validating microstructure modelling approaches.