Researcher profile

Rick Wallace Kenyon

Rick Wallace Kenyon contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
2close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Droop-e: Exponential Droop as a Function of Power Output for Grid-Forming Inverters with Autonomous Power Sharing

This paper presents the novel Droop-e grid-forming inverter control strategy, which establishes an active power-frequency relationship based on an exponential function of the inverter power dispatch. The advantages of this control strategy include an increased utilization of available headroom, mitigated system frequency dynamics, and a natural limiting behavior, all of which are directly compared to the hitherto standard static droop approach. First, the small signal stability of the Droop-e control is assessed on a 3-bus system and found stable across all possible inverter power dispatches. Then, time-domain simulations show improved frequency dynamics at lower power dispatches, and a limiting behavior at higher dispatches. Finally, a novel secondary control scheme is introduced that achieves power sharing following the primary Droop-e response to load perturbations, which is shown to be effective in time-domain simulations of the 3- and 9-bus systems; comparative simulations with a static 5% droop yields unacceptable frequency deviations, highlighting the superiority of the Droop-e control.

preprint2022arXiv

Synchronization in Electric Power Networks with Inherent Heterogeneity Up to 100% Inverter-Based Renewable Generation

The synchronized operation of power generators is the foundation of electric power network stability and a key to the prevention of undesired power outages and blackouts. Here, we derive the conditions that guarantee synchronization in power networks with inherent generator heterogeneity when subjected to small perturbations, and perform a parametric sensitivity analysis to understand synchronization with varied types of generators. As inverter-based resources, which are the primary interfacing technology for many renewable sources of energy, have supplanted synchronous generators in ever growing numbers, the center of attention on associated integration challenges have resided primarily on the role of declining system inertia. Our results instead highlight the critical role of generator damping in achieving a stable state of synchronization. Additionally, we report the feasibility of operating interconnected electric grids with up to 100% power contribution from inverter-based renewable generation technologies. Our study has important implications as it sets the basis for the development of advanced control architectures and grid optimization methods that ensure synchronization and further pave the path towards the decarbonization of the electric power sector.