Source author record

Richard H. Parker

Richard H. Parker appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2019arXiv

Offset Simultaneous Conjugate Atom Interferometers

Correlating the signals from simultaneous atom interferometers has enabled some of the most precise determinations of fundamental constants. Here, we show that multiple interferometers with strategically chosen initial conditions ("offset simultaneous conjugate interferometers" or OSCIs) can provide multi-channel readouts that amplify or suppress specific effects. This allows us to measure the photon recoil, and thus the fine structure constant, while being insensitive to gravity gradients, general acceleration gradients, and unwanted diffraction phases - these effects can be simultaneously monitored in other channels. An expected 4-fold reduction of sensitivity to spatial variations of gravity (due to higher-order gradients) and a 6-fold suppression of diffraction phases paves the way to measurements of the fine structure constant below the 0.1-ppb level, or to simultaneous sensing of gravity, the gravity gradient, and rotations.

preprint2016arXiv

Improved limit on the $^{225}$Ra electric dipole moment

Background: Octupole-deformed nuclei, such as that of $^{225}$Ra, are expected to amplify observable atomic electric dipole moments (EDMs) that arise from time-reversal and parity-violating interactions in the nuclear medium. In 2015, we reported the first "proof-of-principle" measurement of the $^{225}$Ra atomic EDM. Purpose: This work reports on the first of several experimental upgrades to improve the statistical sensitivity of our $^{225}$Ra EDM measurements by orders of magnitude and evaluates systematic effects that contribute to current and future levels of experimental sensitivity. Method: Laser-cooled and trapped $^{225}$Ra atoms are held between two high voltage electrodes in an ultra high vacuum chamber at the center of a magnetically shielded environment. We observe Larmor precession in a uniform magnetic field using nuclear-spin-dependent laser light scattering and look for a phase shift proportional to the applied electric field, which indicates the existence of an EDM. The main improvement to our measurement technique is an order of magnitude increase in spin precession time, which is enabled by an improved vacuum system and a reduction in trap-induced heating. Results: We have measured the $^{225}$Ra atomic EDM to be less than $1.4\times10^{-23}$ $e$ cm (95% confidence upper limit), which is a factor of 36 improvement over our previous result. Conclusions: Our evaluation of systematic effects shows that this measurement is completely limited by statistical uncertainty. Combining this measurement technique with planned experimental upgrades we project a statistical sensitivity at the $1\times10^{-28}$ $e$ cm level and a total systematic uncertainty at the $4\times10^{-29}$ $e$ cm level.