Researcher profile

Ray Fairbend

Ray Fairbend contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2021arXiv

The development of the THESEUS SXI optics

The Transient High Energy Sources and Early Universe Surveyor is an ESA M5 candidate mission currently in Phase A, with Launch in $\sim$2032. The aim of the mission is to complete a Gamma Ray Burst survey and monitor transient X-ray events. The University of Leicester is the PI institute for the Soft X-ray Instrument (SXI), and is responsible for both the optic and detector development. The SXI consists of two wide field, lobster eye X-ray modules. Each module consists of 64 Micro Pore Optics (MPO) in an 8 by 8 array and 8 CMOS detectors in each focal plane. The geometry of the MPOs comprises a square packed array of microscopic pores with a square cross-section, arranged over a spherical surface with a radius of curvature twice the focal length of the optic. Working in the photon energy range 0.3-5 keV, the optimum $L/d$ ratio (length of pore $L$ and pore width $d$) is upwards of 50 and is constant across the whole optic aperture for the SXI. The performance goal for the SXI modules is an angular resolution of 4.5 arcmin, localisation accuracy of $\sim$1 arcmin and employing an $L/d$ of 60. During the Phase A study, we are investigating methods to improve the current performance and consistency of the MPOs, in cooperation with the manufacturer Photonis France SAS. We present the optics design of the THESEUS SXI modules and the programme of work designed to improve the MPOs performance and the results from the study.