Researcher profile

Ralf-Rainer Rohloff

Ralf-Rainer Rohloff contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2014arXiv

Laboratory Results and Status Update for Pathfinder at LBT, The LINC-NIRVANA NGS Ground- Layer AO Subsystem

The full LINC-NIRVANA instrument will be one of the most complex ground-based astronomical systems ever built. It will consist of multiple subsystems, including two multi-conjugate ground layer AO systems (MCAO) that drive the LBT adaptive secondaries, two mid-high layer AO systems with their own Xynetics 349 actuator DM's , a fringe tracker, a beam combiner, and the NIR science camera. In order to mitigate risk, we take a modular approach to instrument testing and commissioning by decoupling these subsystems individually. The first subsystem tested on-sky will be one of the ground-layer AO systems, part of a test-bed known as the Pathfinder. The Pathfinder consists of a 12-star pyramid wavefront sensor (PWFS) that drives one of the LBT's adaptive secondaries, a support structure known as "The Foot," and the infrared test camera (IRTC), which is used for acquisition and alignment. The 12 natural guide stars are acquired by moveable arms called "star enlargers," each of which contains its own optical path. The Pathfinder was shipped from MPIA in Heidelberg, Germany to the LBT mountain lab on Mt. Graham, Arizona in February 2013. The system was unpacked, assembled in the LBT clean room, and internally optically aligned. We present the results of our system tests, including star enlarger alignment and system alignment. We also present our immediate plans for on-sky closed loop tests on the LBT scheduled for late Fall. Because plans for all ELTs call for ground layer correction, the Pathfinder provides valuable preliminary information not only for the full LINC-NIRVANA system, but also for future advanced MCAO systems.

preprint2012arXiv

The GRAVITY Coudé Infrared Adaptive Optics (CIAO) system for the VLT Interferometer

GRAVITY is a second generation instrument for the VLT Interferometer, designed to enhance the near-infrared astrometric and spectro-imaging capabilities of VLTI. Combining beams from four telescopes, GRAVITY will provide an astrometric precision of order 10 micro-arcseconds, imaging resolution of 4 milli-arcseconds, and low and medium resolution spectro-interferometry, pushing its performance far beyond current infrared interfero- metric capabilities. To maximise the performance of GRAVITY, adaptive optics correction will be implemented at each of the VLT Unit Telescopes to correct for the effects of atmospheric turbulence. To achieve this, the GRAVITY project includes a development programme for four new wavefront sensors (WFS) and NIR-optimized real time control system. These devices will enable closed-loop adaptive correction at the four Unit Telescopes in the range 1.4-2.4 μm. This is crucially important for an efficient adaptive optics implementation in regions where optically bright references sources are scarce, such as the Galactic Centre. We present here the design of the GRAVITY wavefront sensors and give an overview of the expected adaptive optics performance under typical observing conditions. Benefiting from newly developed SELEX/ESO SAPHIRA electron avalanche photodiode (eAPD) detectors providing fast readout with low noise in the near-infrared, the AO systems are expected to achieve residual wavefront errors of \leq400 nm at an operating frequency of 500 Hz.