Researcher profile

R. Racine

R. Racine contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2002arXiv

Effects of Quasi-Static Aberrations in Faint Companion Searches

We present the first results obtained at CFHT with the TRIDENT infrared camera, dedicated to the detection of faint companions close to bright nearby stars. The camera's main feature is the acquisition of three simultaneous images in three wavelengths (simultaneous differential imaging) across the methane absorption bandhead at 1.6 micron, that enables a precise subtraction of the primary star PSF while keeping the companion signal. The main limitation is non-common path aberrations between the three optical paths that slightly decorrelate the PSFs. Two types of PSF calibrations are combined with the differential simultaneous imaging technique to further attenuate the PSF: reference star subtraction and instrument rotation to smooth aberrations. It is shown that a faint companion with a DeltaH of 10 magnitudes would be detected at 0.5 arcsec from the primary.

preprint2002arXiv

TRIDENT: an infrared camera optimized for the detection of methanated substellar companions around nearby stars

A near-infrared (0.85-2.5 microns) camera in use at the Canada-France-Hawaii Telescope and at the 1.6m telescope of the Observatoire du Mont-Megantic is described. The camera is based on a Hawaii-1 1024x1024 HgCdTe array detector. Its main feature is to acquire three simultaneous images at three wavelengths (simultaneous differential imaging) across the methane absorption bandhead at 1.6 micron, enabling an accurate subtraction of the stellar point spread function (PSF) and the detection of faint close methanated companions. The instrument has no coronagraph and features a fast (1 MHz) data acquisition system without reset anomaly, yielding high observing efficiencies on bright stars. The performance of the instrument is described, and it is illustrated by CFHT images of the nearby star Ups And. TRIDENT can detect (3 sigma) a methanated companion with DeltaH=10 at 0.5 arcsec from the star in one hour of observing time. Non-common path aberrations between the three optical paths are the limiting factors preventing further PSF attenuation. Reference star subtraction and instrument rotation improve the detection limit by one order of magnitude.