Researcher profile

R. M. Jones

R. M. Jones contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
17works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

17 published item(s)

preprint2012arXiv

A Study of Beam Position Diagnostics with Beam-excited Dipole Higher Order Modes using a Downconverter Test Electronics in Third Harmonic 3.9 GHz Superconducting Accelerating Cavities at FLASH

Beam-excited higher order modes (HOM) in accelerating cavities contain transverse beam position information. Previous studies have narrowed down three modal options for beam position diagnostics in the third harmonic 3.9 GHz cavities at FLASH. Localized modes in the beam pipes at approximately 4.1 GHz and in the fifth cavity dipole band at approximately 9 GHz were found, that can provide a local measurement of the beam position. In contrast, propagating modes in the first and second dipole bands between 4.2 and 5.5 GHz can reach a better resolution. All the options were assessed with a specially designed test electronics built by Fermilab. The aim is to define a mode or spectral region suitable for the HOM electronics. Two data analysis techniques are used and compared in extracting beam position information from the dipole HOMs: direct linear regression and singular value decomposition. Current experiments suggest a resolution of 50 μm accuracy in predicting local beam position using modes in the fifth dipole band, and a global resolution of 20 μm over the complete module. Based on these results we decided to build a HOM electronics for the second dipole band and the fifth dipole band, so that we will have both high resolution measurements for the whole module, and localized measurements for individual cavity. The prototype electronics is being built by Fermilab and planned to be tested in FLASH by the end of 2012.

preprint2012arXiv

Higher Order Modes for Beam Diagnostics in Third Harmonic 3.9 GHz Accelerating Module

An international team is currently investigating the best way to use Higher Order Modes (HOM) for beam diagnostics in 3.9 GHz cavities. HOMs are excited by charged particles when passing through an accelerating structure. Third harmonic cavities working at 3.9 GHz have been installed in FLASH to linearize the bunch energy profile. A proof-of-principle of using HOMs for beam monitoring has been made at FLASH in the TESLA 1.3 GHz cavities. Since the wakefields generated in the 3.9 GHz cavities are significantly larger, their impact on the beam should be carefully minimized. Therefore our target is to monitor HOMs and minimize them by aligning the beam on the cavity axis. The difficulty is that, in comparison to the 1.3 GHz cavities, the HOM-spectrum is dense, making it difficult to identify individual modes. Also, most modes propagate through the whole cryo-module containing several cavities, making it difficult to measure local beam properties. In this paper the options for the HOM-based beam position monitors are discussed.

preprint2012arXiv

Proposal for Single-Bunch Collimator Wakefield Measurements at SLAC ESTB

Collimator wakefields in the Beam Delivery System (BDS) of future linear colliders, such as the International Linear Collider (ILC) and the Compact Linear Collider (CLIC), can be an important source of emittance growth and beam jitter amplification, consequently degrading the luminosity. Therefore, a better understanding of collimator wakefield effects is essential to optimise the collimation systems of future linear colliders in order to minimise wakefield effects. In the past, measurements of single-bunch collimator wakefields have been carried out at SLAC with the aim of benchmarking theory, numerical calculations and experiments. Those studies revealed some discrepancies between the measurements and the theoretical models. New experimental tests using available beam test facilities, such as the End Station A Test Beam (ESTB) at SLAC, would help to improve our understanding on collimator wakefields. ESTB will provide the perfect test bed to investigate collimator wakefields for different bunch length conditions, relevant for both ILC (300 micrometers nominal bunch length) and CLIC (44 micrometers nominal bunch length) studies. Here we propose to perform new experimental tests of collimator wakefield effects on electron/positron beams at SLAC ESTB.

preprint2012arXiv

Simulations of higher order modes in the ACC39 module of FLASH

This study is focused on the development of a HOM-based BPM system for the ACC39 module currently installed and in operation at FLASH. A similar system is anticipated to be installed at XFEL. Coupled inter-cavity modes are simulated together with a limited band of trapped modes. A suite of finite element computer codes (including HFSS and ACE3P) and globalised scattering matrix calculations (GSM) are used to investigate the modes in these cavities with a view to providing guidance on their use as a cavity beam diagnostic.

preprint2011arXiv

A Study of Beam Alignment Based on Coupling Modes in Third Harmonic Superconducting Cavities at FLASH

This paper presents a study of beam alignment in accelerating cavities based on beam-excited higher order modes (HOM). Among the transverse HOMs, dipole modes have the dominant contribution, and may have an adverse effect on the beam quality. Since they depend linearly on the transverse beam offset, their effect can be reduced by aligning the beam in the cavity. The study has been made on the four third harmonic superconducting cavities installed in the ACC39 module at FLASH. Modes with strong beam coupling were monitored while moving the beam and searching for the minimum excited HOM power.

preprint2011arXiv

Beam-based HOM Study in Third Harmonic SC Cavities for Beam Alignment at FLASH

An electron beam entering an accelerator cavity excites higher order modes (HOM). These are radiated to HOM couplers and subsequently damped. They can also be used to facilitate beam position monitoring. The modes excited by off-axis beams are the focus of this study. Results are presented on the first analysis of HOM dependency on the beam position for the third harmonic cavities at FLASH. The analysis is based on the beampipe and cavity dipole modes. Various analysis methods are used and compared to satisfy the needs emerging from the characteristics of those modes. The electric center of each mode is observed by looking for the minima of the HOM signals of different beam positions. A single electron bunch per RF pulse is used.

preprint2011arXiv

Comparative Wakefield Analysis of a First Prototype of a DDS Structure for CLIC Main Linac

A Damped Detuned Structure (DDS) for CLIC main linac has been proposed as an alternative to the present baseline design which is based on heavy damping. A first prototype, CLIC_DDS_A, for high power tests has been already designed and is under construction. It is also foreseen to design a further prototype, CLIC_DDS_B, to test both the wakefield suppression and high power performances. Wakefield calculations for DDS are, in the early design stage, based on single infinitely periodic cells. Though cell-to-cell interaction is taken into account to calculate the wakefields, it is important to study full structure properties using computational tools. In particular this is fundamental for defining the input parameters for the HOM coupler that is crucial for the performances of DDS. In the following a full analysis of wakefields and impedances based on simulations conducted with finite difference based electromagnetic computer code GdfidL will be presented.

preprint2011arXiv

Higher Order Modes in Coupled Cavities of the Flash Module ACC39

We analyse the higher order modes (HOM's) in the 3.9GHz bunch shaping cavities installed in the FLASH facility at DESY. A suite of finite element computer codes (including HFSS and ACE3P) and globalised scattering matrix calculations (GSM) are used to investigate the modes in these cavities. This study is primarily focused on the dipole component of the multiband expansion of the wakefield, with the emphasis being on the development of a HOM-based BPM system for ACC39. Coupled inter-cavity modes are simulated together with a limited band of trapped modes.

preprint2011arXiv

Study of Beam Diagnostics with Trapped Modes in Third Harmonic Superconducting Cavities at FLASH

Off-axis beams passing through an accelerating cavity excite dipole modes among other higher order modes (HOMs). These modes have linear dependence on the transverse beam offset from the cavity axis. Therefore they can be used to monitor the beam position within the cavity. The fifth dipole passband of the third harmonic superconducting cavities at FLASH has modes trapped within each cavity and do not propagate through the adjacent beam pipes, while most other cavity modes do. This could enable the beam position measurement in individual cavities. This paper investigates the possibility to use the fifth dipole band for beam alignment in the third harmonic cavity module. Simulations and measurements both with and without beam-excitations are presented. Various analysis methods are used and compared. A good correlation of HOM signals to the beam position is observed.

preprint2010arXiv

A High Phase Advance Damped and Detuned Structure for the Main Linacs of Clic

The main accelerating structures for the CLIC are designed to operate at an average accelerating gradient of 100 MV/m. The accelerating frequency has been optimised to 11.994 GHz with a phase advance of 2π/3 of the main accelerating mode. The moderately damped and detuned structure (DDS) design is being studied as an alternative to the strongly damped WDS design. Both these designs are based on the nominal accelerating phase advance. Here we explore high phase advance (HPA) structures in which the group velocity of the rf fields is reduced compared to that of standard (2π/3) structures. The electrical breakdown strongly depends on the fundamental mode group velocity. Hence it is expected that electrical breakdown is less likely to occur in the HPA structures. We report on a study of both the fundamental and dipole modes in a CLIC_DDS_HPA structure, designed to operate at 5π/6 phase advance per cell. Higher order dipole modes in both the standard and HPA structures are also studied.

preprint2010arXiv

Beam Dynamics Studies of the REX-ISOLDE Linac in Preparation for its Role as Injector for the HIE-ISOLDE SC Linac at CERN

The superconducting (SC) High Intensity and Energy (HIE) ISOLDE linac will replace most of the existing accelerating infrastructure of the Radioactive ion beam EXperiment (REX) at CERN, however, the 101.28 MHz RFQ and 5 MV IH cavity will remain in the role of injector for the upgrade, boosting the beam up to an energy of 1.2 MeV/u. We present the results of a beam dynamics investigation of the injector focused most critically on matching the longitudinal beam parameters from the RFQ to the SC machine, which is complicated largely by the IH cavity employing a Combined Zero Degree (KONUS) beam dynamics design. The longitudinal beam parameters at the RFQ are reconstructed from measurement using the three gradient method and combined with beam dynamics measurements and simulations of the IH structure to design the matching section for the SC linac.

preprint2010arXiv

First Beam Spectra of SC Third Harmonic Cavity at FLASH

Third harmonic superconducting cavities have been designed and fabricated by FNAL to minimise the energy spread along bunches in the FLASH facility at DESY. A module, consisting of four nine-cell 3.9 GHz cavities, has been installed in FLASH. The first measurement with beam excitation is presented, and the comparisons to transmission measurement without beam and simulations are made. Higher order modes (HOMs) are able to propagate to adjacent cavities through attached beam tubes. Modes from 1.3 GHz cavities in the module nearby also propagate into this module.

preprint2010arXiv

Higher Order Modes In Third Harmonic Cavities at Flash

Transverse modes in the 3.9 GHz cavities, designed and fabricated by FNAL, are reported on. These modes have the potential to cause significant emittance dilution if they are not sufficiently suppressed. Recent probe-based-experiments have indicated significant discrepancies between modes predicted in stand-alone 9-cell cavities compared to those in 4-cavity modules. We employ the code HFSS to analyze these modes, coupled through beam tubes whose cut-off is above that of the first dipole band.

preprint2010arXiv

Status of COLDDIAG: A Cold Vacuum Chamber for Diagnostics

One of the still open issues for the development of superconducting insertion devices is the understanding of the beam heat load. With the aim of measuring the beam heat load to a cold bore and the hope to gain a deeper understanding in the beam heat load mechanisms, a cold vacuum chamber for diagnostics is under construction. The following diagnostics will be implemented: i) retarding field analyzers to measure the electron energy and flux, ii) temperature sensors to measure the total heat load, iii) pressure gauges, iv) and mass spectrometers to measure the gas content. The inner vacuum chamber will be removable in order to test different geometries and materials. This will allow the installation of the cryostat in different synchrotron light sources. COLDDIAG will be built to fit in a short straight section at ANKA. A first installation at the synchrotron light source Diamond is foreseen in June 2011. Here we describe the technical design report of this device and the planned measurements with beam.