Researcher profile

R. Holzwarth

R. Holzwarth contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2020arXiv

Measuring and characterizing the line profile of HARPS with a laser frequency comb

Aims. We study the 2D spectral line profile of HARPS (High Accuracy Radial Velocity Planet Searcher), measuring its variation with position across the detector and with changing line intensity. The characterization of the line profile and its variations are important for achieving the precision of the wavelength scales of 10^{-10} or 3.0 cm/s necessary to detect Earth-twins in the habitable zone around solar-like stars. Methods. We used a laser frequency comb (LFC) with unresolved and unblended lines to probe the instrument line profile. We injected the LFC light (attenuated by various neutral density filters) into both the object and the reference fibres of HARPS, and we studied the variations of the line profiles with the line intensities. We applied moment analysis to measure the line positions, widths, and skewness as well as to characterize the line profile distortions induced by the spectrograph and detectors. Based on this, we established a model to correct for point spread function distortions by tracking the beam profiles in both fibres. Results. We demonstrate that the line profile varies with the position on the detector and as a function of line intensities. This is consistent with a charge transfer inefficiency (CTI) effect on the HARPS detector. The estimate of the line position depends critically on the line profile, and therefore a change in the line amplitude effectively changes the measured position of the lines, affecting the stability of the wavelength scale of the instrument. We deduce and apply the correcting functions to re-calibrate and mitigate this effect, reducing it to a level consistent with photon noise.

preprint2012arXiv

A Laser Frequency Comb System for Absolute Calibration of the VTT Echelle Spectrograph

A wavelength calibration system based on a laser frequency comb (LFC) was developed in a co-operation between the Kiepenheuer-Institut für Sonnenphysik, Freiburg, Germany and the Max-Planck-Institut für Quantenoptik, Garching, Germany for permanent installation at the German Vacuum Tower Telescope (VTT) on Tenerife, Canary Islands. The system was installed successfully in October 2011. By simultaneously recording the spectra from the Sun and the LFC, for each exposure a calibration curve can be derived from the known frequencies of the comb modes that is suitable for absolute calibration at the meters per second level. We briefly summarize some topics in solar physics that benefit from absolute spectroscopy and point out the advantages of LFC compared to traditional calibration techniques. We also sketch the basic setup of the VTT calibration system and its integration with the existing echelle spectrograph.

preprint2012arXiv

Mid-Infrared Optical Frequency Combs based on Crystalline Microresonators

The mid-infrared spectral range (2 to 20 μm) is of particular importance for chemistry, biology and physics as many molecules exhibit strong ro-vibrational fingerprints. Frequency combs - broad spectral bandwidth coherent light sources consisting of equally spaced sharp lines - are creating new opportunities for advanced spectroscopy. Mid-infrared frequency comb sources have recently emerged but are still facing technological challenges, like achieving high power per comb line and tens of GHz line spacing as required for e.g. direct comb spectroscopy. Here we demonstrate a novel approach to create such a frequency comb via four-wave mixing in a continuous-wave pumped ultra-high Q crystalline microresonator made of magnesium fluoride. Careful choice of the resonator material and design made it possible to generate a broad comb of narrow lines in the mid-infrared: a vast cascade of about 100 lines spaced by 100 GHz spanning 200 nm (~10 THz) at λ=2.5 μm. With its distinguishing features of compactness, efficient conversion, large mode spacing and high power per comb line, this novel frequency comb source holds promise for new approaches to molecular spectroscopy even deeper in the mid-infrared.

preprint2012arXiv

The Space Optical Clocks Project: Development of high-performance transportable and breadboard optical clocks and advanced subsystems

The use of ultra-precise optical clocks in space ("master clocks") will allow for a range of new applications in the fields of fundamental physics (tests of Einstein's theory of General Relativity, time and frequency metrology by means of the comparison of distant terrestrial clocks), geophysics (mapping of the gravitational potential of Earth), and astronomy (providing local oscillators for radio ranging and interferometry in space). Within the ELIPS-3 program of ESA, the "Space Optical Clocks" (SOC) project aims to install and to operate an optical lattice clock on the ISS towards the end of this decade, as a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Undertaking a necessary step towards optical clocks in space, the EU-FP7-SPACE-2010-1 project no. 263500 (SOC2) (2011-2015) aims at two "engineering confidence", accurate transportable lattice optical clock demonstrators having relative frequency instability below 1\times10^-15 at 1 s integration time and relative inaccuracy below 5\times10^-17. This goal performance is about 2 and 1 orders better in instability and inaccuracy, respectively, than today's best transportable clocks. The devices will be based on trapped neutral ytterbium and strontium atoms. One device will be a breadboard. The two systems will be validated in laboratory environments and their performance will be established by comparison with laboratory optical clocks and primary frequency standards. In this paper we present the project and the results achieved during the first year.

preprint2011arXiv

Characterizing a fiber-based frequency comb with electro-optic modulator

We report on the characterization of a commercial-core fiber-based frequency comb equipped with an intracavity electro-optic modulator (EOM). We investigate the relationship between the noise of the pump diode and the laser relative intensity noise (RIN) and demonstrate the use of a low noise current supply to substantially reduce the laser RIN. By measuring several transfer functions, we evaluate the potentiality of the EOM for comb repetition rate stabilization. We also evaluate the coupling to other relevant parameters of the comb. From these measureemnts, we infer the capabilities of the femtosecond laser comb to generate very low phase noise microwave signals when phase locked to a high spectral purity ultra-stable laser.

preprint2011arXiv

Comment on "Missing Transverse-Doppler Effect in Time-Dilation Experiments with High-Speed Ions"

In an article "Missing Transverse-Doppler Effect in Time-Dilation Experiments with High-Speed Ions" by S. Devasia [arXiv:1003.2970v1], our recent Doppler shift experiments on fast ion beams are reanalyzed. Contrary to our analysis, Devasia concludes that our results provide an "indication of Lorentz violation". We argue that this conclusion is based on a fundamental misunderstanding of our experimental scheme and reiterate that our results are in excellent agreement with Special Relativity.