Source author record

Prakash K. Ray

Prakash K. Ray appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2016arXiv

Bacterial Foraging Optimized STATCOM for Stability Assessment in Power System

This paper presents a study of improvement in stability in a single machine connected to infinite bus (SMIB) power system by using static compensator (STATCOM). The gains of Proportional-Integral-Derivative (PID) controller in STATCOM are being optimized by heuristic technique based on Particle swarm optimization (PSO). Further, Bacterial Foraging Optimization (BFO) as an alternative heuristic method is also applied to select optimal gains of PID controller. The performance of STATCOM with the above soft-computing techniques are studied and compared with the conventional PID controller under various scenarios. The simulation results are accompanied with performance indices based quantitative analysis. The analysis clearly signifies the robustness of the new scheme in terms of stability and voltage regulation when compared with conventional PID.

preprint2016arXiv

Fault Detection in IEEE 14-Bus Power System with DG Penetration Using Wavelet Transform

Wavelet transform is proposed in this paper for detection of islanding and fault disturbances distributed generation (DG) based power system. An IEEE 14-bus system with DG penetration is considered for the detection of disturbances under different operating conditions. The power system is a hybrid combination of photovoltaic, and wind energy system connected to different buses with different level of penetration. The voltage signal is retrieved at the point of common coupling (PCC) and processed through wavelet transform to detect the disturbances. Further, energy and standard deviation (STD) as performance indices are evaluated and compared with a suitable threshold in order to analyze a disturbance condition. Again, a comparative analysis between the existing and proposed detection is studied to prove the better performance of wavelet transform.