Researcher profile

Pierre Billoir

Pierre Billoir contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
8works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2023arXiv

An Improved Method of Estimating the Uncertainty of Air-Shower Size at Ultra-High Energies

The collection of a statistically significant number detected of cosmic rays with energy above $10^{17}$ to $10^{18}$ eV requires widely-spaced particle detectors at the ground level to detect the extensive air showers induced in the atmosphere. The air-shower sizes, proxies of the primary energies, are then estimated by fitting the observed signals to a functional form for expectations so as to interpolate the signal at a reference distance. The functional form describes the rapid falloff of the expected signal with the distance from the shower core, using typically two logarithmic slopes to account for the short-range and long-range decreases of signals. The uncertainties associated to the air-shower sizes are determined under the assumption of a quadratic dependence of the log-likelihood on the fitted parameters around the minimum, so that a meaningful variance-covariance matrix is provided. In this paper, we show that for an event topology where one signal is much larger than the others, the quadratic dependence of the fitted function around the minimum is a poor approximation that leads to an inaccurate estimate of the uncertainties. To restore a quadratic shape, we propose to use the polar coordinates around the detector recording the largest signal, projected onto the plane of the shower front, to define the likelihood function in terms of logarithmic polar distances, polar angles and logarithmic shower sizes as free parameters. We show that a meaningful variance-covariance matrix is then recovered in the new coordinate system, as the dependence of the fitted function on the modified parameters is properly approximated by a quadratic function. The use of the uncertainties in the new coordinate system for subsequent high-level analyses is illustrated.

preprint2016arXiv

Energy Estimation of Cosmic Rays with the Engineering Radio Array of the Pierre Auger Observatory

The Auger Engineering Radio Array (AERA) is part of the Pierre Auger Observatory and is used to detect the radio emission of cosmic-ray air showers. These observations are compared to the data of the surface detector stations of the Observatory, which provide well-calibrated information on the cosmic-ray energies and arrival directions. The response of the radio stations in the 30 to 80 MHz regime has been thoroughly calibrated to enable the reconstruction of the incoming electric field. For the latter, the energy deposit per area is determined from the radio pulses at each observer position and is interpolated using a two-dimensional function that takes into account signal asymmetries due to interference between the geomagnetic and charge-excess emission components. The spatial integral over the signal distribution gives a direct measurement of the energy transferred from the primary cosmic ray into radio emission in the AERA frequency range. We measure 15.8 MeV of radiation energy for a 1 EeV air shower arriving perpendicularly to the geomagnetic field. This radiation energy -- corrected for geometrical effects -- is used as a cosmic-ray energy estimator. Performing an absolute energy calibration against the surface-detector information, we observe that this radio-energy estimator scales quadratically with the cosmic-ray energy as expected for coherent emission. We find an energy resolution of the radio reconstruction of 22% for the data set and 17% for a high-quality subset containing only events with at least five radio stations with signal.

preprint2016arXiv

Measurement of the Radiation Energy in the Radio Signal of Extensive Air Showers as a Universal Estimator of Cosmic-Ray Energy

We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 \pm 0.7 (stat) \pm 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.

preprint2015arXiv

An improved limit to the diffuse flux of ultra-high energy neutrinos from the Pierre Auger Observatory

Neutrinos in the cosmic ray flux with energies near 1 EeV and above are detectable with the Surface Detector array of the Pierre Auger Observatory. We report here on searches through Auger data from 1 January 2004 until 20 June 2013. No neutrino candidates were found, yielding a limit to the diffuse flux of ultra-high energy neutrinos that challenges the Waxman-Bahcall bound predictions. Neutrino identification is attempted using the broad time-structure of the signals expected in the SD stations, and is efficiently done for neutrinos of all flavors interacting in the atmosphere at large zenith angles, as well as for &#34;Earth-skimming&#34; neutrino interactions in the case of tau neutrinos. In this paper the searches for downward-going neutrinos in the zenith angle bins $60^\circ-75^\circ$ and $75^\circ-90^\circ$ as well as for upward-going neutrinos, are combined to give a single limit. The $90\%$ C.L. single-flavor limit to the diffuse flux of ultra-high energy neutrinos with an $E^{-2}$ spectrum in the energy range $1.0 \times 10^{17}$ eV - $2.5 \times 10^{19}$ eV is $E_ν^2 dN_ν/dE_ν< 6.4 \times 10^{-9}~ {\rm GeV~ cm^{-2}~ s^{-1}~ sr^{-1}}$.

preprint2015arXiv

Exploiting the geomagnetic distortion of the inclined atmospheric showers

We propose a novel approach for the determination of the nature of ultra-high energy cosmic rays by exploiting the geomagnetic deviation of muons in nearly horizontal showers. The distribution of the muons at ground level is well described by a simple parametrization providing a few shape parameters tightly correlated to $X^μ_\mathrm{max}$, the depth of maximal muon production, which is a mass indicator tightly correlated to the usual parameter $X_\mathrm{max}$, the depth of maximal development of the shower. We show that some constraints can be set on the predictions of hadronic models, especially by combining the geomagnetic distortion with standard measurement of the longitudinal profile. We discuss the precision needed to obtain significant results and we propose a schematic layout of a detector.

preprint2015arXiv

Measurement of the cosmic ray spectrum above $4{\times}10^{18}$ eV using inclined events detected with the Pierre Auger Observatory

A measurement of the cosmic-ray spectrum for energies exceeding $4{\times}10^{18}$ eV is presented, which is based on the analysis of showers with zenith angles greater than $60^{\circ}$ detected with the Pierre Auger Observatory between 1 January 2004 and 31 December 2013. The measured spectrum confirms a flux suppression at the highest energies. Above $5.3{\times}10^{18}$ eV, the &#34;ankle&#34;, the flux can be described by a power law $E^{-γ}$ with index $γ=2.70 \pm 0.02 \,\text{(stat)} \pm 0.1\,\text{(sys)}$ followed by a smooth suppression region. For the energy ($E_\text{s}$) at which the spectral flux has fallen to one-half of its extrapolated value in the absence of suppression, we find $E_\text{s}=(5.12\pm0.25\,\text{(stat)}^{+1.0}_{-1.2}\,\text{(sys)}){\times}10^{19}$ eV.

preprint2014arXiv

Layered water Cherenkov detector for the study of ultra high energy cosmic rays

We present a new design for the water Cherenkov detectors that are in use in various cosmic ray observatories. This novel design can provide a significant improvement in the independent measurement of the muonic and electromagnetic component of extensive air showers. From such multi-component data an event by event classification of the primary cosmic ray mass becomes possible. According to popular hadronic interaction models, such as EPOS-LHC or QGSJetII-04, the discriminating power between iron and hydrogen primaries reaches Fisher values of $\sim$ 2 or above for energies in excess of $10^{19}$ eV with a detector array layout similar to that of the Pierre Auger Observatory.

preprint2010arXiv

A phenomenological model of the muon density profile on the ground of very inclined air showers

Ultra-high energy cosmic rays generate extensive air showers in Earth&#39;s atmosphere. A standard approach to reconstruct the energy of an ultra-high energy cosmic rays is to sample the lateral profile of the particle density on the ground of the air shower with an array of surface detectors. For cosmic rays with large inclinations, this reconstruction is based on a model of the lateral profile of the muon density observed on the ground, which is fitted to the observed muon densities in individual surface detectors. The best models for this task are derived from detailed Monte-Carlo simulations of the air shower development. We present a phenomenological parametrization scheme which allows to derive a model of the average lateral profile of the muon density directly from a fit to a set of individual Monte-Carlo simulated air showers. The model reproduces the detailed simulations with a high precision. As an example, we generate a muon density model which is valid in the energy range 1e18 eV < E < 1e20 eV and the zenith angle range 60 deg < theta < 90 deg. We will further demonstrate a way to speed up the simulation of such muon profiles by three orders of magnitude, if only the muons in the shower are of interest.