Researcher profile

Philippe Quétin

Philippe Quétin contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - Baseline
1works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2021arXiv

Automatic Segmentation and Location Learning of Neonatal Cerebral Ventricles in 3D Ultrasound Data Combining CNN and CPPN

Preterm neonates are highly likely to suffer from ventriculomegaly, a dilation of the Cerebral Ventricular System (CVS). This condition can develop into life-threatening hydrocephalus and is correlated with future neuro-developmental impairments. Consequently, it must be detected and monitored by physicians. In clinical routing, manual 2D measurements are performed on 2D ultrasound (US) images to estimate the CVS volume but this practice is imprecise due to the unavailability of 3D information. A way to tackle this problem would be to develop automatic CVS segmentation algorithms for 3D US data. In this paper, we investigate the potential of 2D and 3D Convolutional Neural Networks (CNN) to solve this complex task and propose to use Compositional Pattern Producing Network (CPPN) to enable the CNNs to learn CVS location. Our database was composed of 25 3D US volumes collected on 21 preterm nenonates at the age of $35.8 \pm 1.6$ gestational weeks. We found that the CPPN enables to encode CVS location, which increases the accuracy of the CNNs when they have few layers. Accuracy of the 2D and 3D CNNs reached intraobserver variability (IOV) in the case of dilated ventricles with Dice of $0.893 \pm 0.008$ and $0.886 \pm 0.004$ respectively (IOV = $0.898 \pm 0.008$) and with volume errors of $0.45 \pm 0.42$ cm$^3$ and $0.36 \pm 0.24$ cm$^3$ respectively (IOV = $0.41 \pm 0.05$ cm$^3$). 3D CNNs were more accurate than 2D CNNs in the case of normal ventricles with Dice of $0.797 \pm 0.041$ against $0.776 \pm 0.038$ (IOV = $0.816 \pm 0.009$) and volume errors of $0.35 \pm 0.29$ cm$^3$ against $0.35 \pm 0.24$ cm$^3$ (IOV = $0.2 \pm 0.11$ cm$^3$). The best segmentation time of volumes of size $320 \times 320 \times 320$ was obtained by a 2D CNN in $3.5 \pm 0.2$ s.