Researcher profile

Philippe Peille

Philippe Peille contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

A 50 mK test bench for demonstration of the readout chain of Athena/X-IFU

The X-IFU (X-ray Integral Field Unit) onboard the large ESA mission Athena (Advanced Telescope for High ENergy Astrophysics), planned to be launched in the mid 2030s, will be a cryogenic X-ray imaging spectrometer operating at 55 mK. It will provide unprecedented spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) in the 0.2-12 keV energy range thanks to its array of TES (Transition Edge Sensors) microcalorimeters of more than 2k pixel. The detection chain of the instrument is developed by an international collaboration: the detector array by NASA/GSFC, the cold electronics by NIST, the cold amplifier by VTT, the WFEE (Warm Front-End Electronics) by APC, the DRE (Digital Readout Electronics) by IRAP and a focal plane assembly by SRON. To assess the operation of the complete readout chain of the X-IFU, a 50 mK test bench based on a kilo-pixel array of microcalorimeters from NASA/GSFC has been developed at IRAP in collaboration with CNES. Validation of the test bench has been performed with an intermediate detection chain entirely from NIST and Goddard. Next planned activities include the integration of DRE and WFEE prototypes in order to perform an end-to-end demonstration of a complete X-IFU detection chain.

preprint2021arXiv

Pulse processing in TES detectors: comparison of different short filter methods based on optimal filtering. Case study for Athena X-IFU

In the framework of the ESA Athena mission, the X-ray Integral Field Unit (X-IFU) instrument to be on board the X-ray Athena Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors aimed at providing spatially resolved high-resolution spectroscopy. As a part of the on-board Event Processor (EP), the reconstruction software will provide the energy, spatial location and arrival time of the incoming X-ray photons hitting the detector and inducing current pulses on it. Being the standard optimal filtering technique the chosen baseline reconstruction algorithm, different modifications have been analyzed to process pulses shorter than those considered of high resolution (those where the full length is not available due to a close pulse after them) in order to select the best option based on energy resolution and computing performance results. It can be concluded that the best approach to optimize the energy resolution for short filters is the 0-padding filtering technique, benefiting also from a reduction in the computational resources. However, its high sensitivity to offset fluctuations currently prevents its use as the baseline treatment for the X-IFU application for lack of consolidated information on the actual stability it will get in flight.

preprint2020arXiv

Modeling the upper kHz QPOs of 4U 1728-34 with X-ray reverberation

While kilohertz quasi-periodic oscillations (kHz QPOs) have been well studied for decades since their initial discovery, the cause of these signals remains unknown, as no model has been able to accurately predict all of their spectral and timing properties. Separately, X-ray reverberation lags have been detected in AGN and stellar-mass black hole binaries, and reverberation may be expected to occur in neutron star systems as well, producing lags of the same amplitude as the lags measured of the kHz QPOs. Furthermore, the detection of a relativistically reflected Fe K line in the time-averaged spectra of many neutron star systems provides an additional motivation for testing reverberation. While it has been shown that the lag-energy properties of the lower kHz QPOs are unlikely to be produced by X-ray reverberation, the upper kHz QPOs have not yet been explored. We therefore model the upper kHz QPO lag-energy spectra using relativistic ray-tracing functions and apply them to archival RXTE data on 4U 1728-34 where upper kHz QPOs have been detected. By modeling the time-averaged spectra in which upper kHz QPOs had been significantly detected, we determine the reflected flux fraction across all energies and produce a model for the lag-energy spectra from X-ray reverberation. We explore the dependence of the modeled lag properties on several different types of reflection models, but are unable to successfully reproduce the measured lags of 4U 1728-34. We conclude that reverberation alone does not explain the measured time lags detected in upper kHz QPOs.

preprint2020arXiv

Thermal simulations of temperature excursions on the Athena X-IFU detector wafer from impacts by cosmic rays

We present the design and implementation of a thermal model, developed in COMSOL, aiming to probe the wafer-scale thermal response arising from realistic rates and energies of cosmic rays at L2 impacting the detector wafer of Athena X-IFU. The wafer thermal model is a four-layer 2D model, where 2 layers represent the constituent materials (Si bulk and Si$_{3}$N$_{4}$ membrane), and 2 layers represent the Au metallization layer's phonon and electron temperatures. We base the simulation geometry on the current specifications for the X-IFU detector wafer, and simulate cosmic ray impacts using a simple power injection into the Si bulk. We measure the temperature at the point of the instrument's most central TES detector. By probing the response of the system and pulse characteristics as a function of the thermal input energy and location, we reconstruct cosmic ray pulses in Python. By utilizing this code, along with the results of the GEANT4 simulations produced for X-IFU, we produce realistic time-ordered data (TOD) of the temperature seen by the central TES, which we use to simulate the degradation of the energy resolution of the instrument in space-like conditions on this wafer. We find a degradation to the energy resolution of 7 keV X-rays of $\approx$0.04 eV. By modifying wafer parameters and comparing the simulated TOD, this study is a valuable tool for probing design changes on the thermal background seen by the detectors.