Researcher profile

Phil Hinz

Phil Hinz contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

High contrast imaging with Fizeau interferometry: The case of Altair

The Large Binocular Telescope (LBT) has two 8.4-m primary mirrors that produce beams that can be combined coherently in a "Fizeau" interferometric mode. In principle, the Fizeau PSF enables the probing of structure at a resolution up to three times better than that of the adaptive-optics-corrected PSF of a single 8.4-m telescope. In this work, we examined the nearby star Altair (5.13 pc, type A7V, $\sim$100s Myr to $\approx$1.4 Gyr) in the Fizeau mode with the LBT at Br-$α$ (4.05 $μ$m) and carried out angular differential imaging to search for companions. This work presents the first filled-aperture LBT Fizeau science dataset to benefit from a correcting mirror which provides active phase control. In the analysis of the $λ/D$ angular regime, the sensitivity of the dataset is down to $\approx$0.5 $M_{\odot}$ at 1" for a 1.0 Gyr system. This sensitivity remains limited by the small amount of integration time, which is in turn limited by the instability of the Fizeau PSF. However, in the Fizeau fringe regime we attain sensitivities of $Δm \approx 5$ at 0.2" and put constraints to companions of 1.3 $M_{\odot}$ down to an inner angle of $\approx$0.15", closer than any previously published direct imaging of Altair. This analysis is a pathfinder for future datasets of this type, and represents some of the first steps to unlocking the potential of the first ELT. Fizeau observations will be able to reach dimmer targets with upgrades to the instrument, in particular the phase detector.

preprint2022arXiv

SCALES for Keck: Optical Design

SCALES is a high-contrast, infrared coronagraphic imager and integral field spectrograph (IFS) to be deployed behind the W.M. Keck Observatory adaptive optics system. A reflective optical design allows diffraction-limited imaging over a large wavelength range (1.0 - 5.0 microns). A microlens array-based IFS coupled with a lenslet reformatter ("slenslit") allow spectroscopy at both low (R = 35 - 250) and moderate (R = 2000 - 6500) spectral resolutions. The large wavelength range, diffraction-limited performance, high contrast coronagraphy and cryogenic operation present a unique optical design challenge. We present the full SCALES optical design, including performance modeling and analysis and manufacturing.

preprint2021arXiv

Bringing SOUL on sky

The SOUL project is upgrading the 4 SCAO systems of LBT, pushing the current guide star limits of about 2 magnitudes fainter thanks to Electron Multiplied CCD detector. This improvement will open the NGS SCAO correction to a wider number of scientific cases from high contrast imaging in the visible to extra-galactic source in the NIR. The SOUL systems are today the unique case where pyramid WFS, adaptive secondary and EMCCD are used together. This makes SOUL a pathfinder for most of the ELT SCAO systems like the one of GMT, MICADO and HARMONI of E-ELT, where the same key technologies will be employed. Today we have 3 SOUL systems installed on the telescope in commissioning phase. The 4th system will be installed in a few months. We will present here the results achieved during daytime testing and commissioning nights up to the present date.

preprint2020arXiv

Implementing multi-wavelength fringe tracking for the Large Binocular Telescope Interferometer's phase sensor, PHASECam

PHASECam is the fringe tracker for the Large Binocular Telescope Interferometer (LBTI). It is a near-infrared camera which is used to measure both tip/tilt and fringe phase variations between the two adaptive optics (AO) corrected apertures of the Large Binocular Telescope (LBT). Tip/tilt and phase sensing are currently performed in the $H$ (1.65 $μ$m) and $K$ (2.2 $μ$m) bands at 1 kHz, but only the $K$-band phase telemetry is used to send corrections to the system in order to maintain fringe coherence and visibility. However, due to the cyclic nature of the fringe phase, only the phase, modulo 360 deg, can be measured. PHASECam's phase unwrapping algorithm, which attempts to mitigate this issue, occasionally fails in the case of fast, large phase variations or low signal-to-noise ratio. This can cause a fringe jump, in which case the OPD correction will be incorrect by a wavelength. This can currently be manually corrected by the operator. However, as the LBTI commissions further modes which require robust, active phase control and for which fringe jumps are harder to detect, including multi-axial (Fizeau) interferometry and dual-aperture non-redundant aperture masking interferometry, a more reliable and automated solution is desired. We present a multi-wavelength method of fringe jump capture and correction which involves direct comparison between the $K$-band and $H$-band phase telemetry. We demonstrate the method utilizing archival PHASECam telemetry, showing it provides a robust, reliable way of detecting fringe jumps which can potentially recover a significant fraction of the data lost to them.