Source author record

Peter Lusis

Peter Lusis appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Interaction Between Coordinated and Droop Control PV Inverters

Autonomous droop control PV inverters have improved voltage regulation compared to the inverters without grid support functions, but more flexible control techniques will be required as the number of solar photovoltaic (PV) installations increases. This paper studies three inverter future deployment scenarios with droop control inverters, non-exporting inverters, and coordinated inverter control (CIC). The network operation and the interaction between various inverter control methods are studied by simulating inverter operation on two low-voltage networks. Considering 30% PV penetration as the base case, we demonstrate that coordinated inverters can mitigate overvoltages and voltage fluctuations caused by the tripping of passive inverters in 85% of PV location cases when at least as many coordinated as passive inverters are deployed on the 114-node test feeder. However, this rate reduced to 37% with the IEEE 906-node network demonstrating that the deployment of coordinated inverter control may not be able to reverse passive inverter-related voltage disturbances when the build-up of passive inverters has reached a certain threshold. The aggregated PV output from coordinated inverters can be also used to provide grid support services. When the low-voltage networks operate close to the upper voltage limits, the change in the power output from coordinated inverters following a regulation request may be partially offset by passive inverters. Considering an equal number of passive and coordinated inverters, this paper shows that for each unit of the down-regulation request delivered by coordinated inverters, passive inverter output may increase by up to 0.2 units and decrease by up to 0.45 units during coordinated inverter up-regulation.

preprint2020arXiv

Reducing the Unfairness of Coordinated Inverter Dispatch in PV-Rich Distribution Networks

The integration of a high share of solar photovoltaics (PV) in distribution networks requires advanced voltage control technologies or network augmentation, both associated with significant investment costs. An alternative is to prevent new customers from installing solar PV systems, but this is against the common goal of increasing renewable energy generation. This paper demonstrates that solar PV curtailment in low voltage areas can be reduced and fairly distributed among PV owners by centrally coordinating the operation of PV inverters. The optimal inverter active and reactive power operation points are computed by solving a multi-objective optimization problem with a fairness objective. The main results show that fair optimal inverter dispatch (FOID) results in less power curtailment than passive voltage regulation based on Volt/VAr droop control, especially at high solar PV to load ratios. The effectiveness of the model is demonstrated on a residential low voltage network.