Source author record

Peter Jakobsen

Peter Jakobsen appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Astrometric and Wavelength Calibration of the NIRSpec Instrument during Commissioning using a model-based approach

The NIRSpec instrument for the James Webb Space Telescope (JWST) is a highly versatile near-infrared spectrograph that can be operated in various observing modes, slit apertures, and spectral resolutions. Obtaining dedicated calibration data for all possible combinations of aperture and disperser is an intractable task. We have therefore developed a procedure to derive a highly realistic model of the instrument's optical geometry across the entire field of view, using calibration data acquired through only a subset of NIRSpec apertures, which nevertheless allows the light paths within the spectrograph to be accurately computed for all apertures and all observing modes. This parametric instrument model thus provides the basis for the extraction of wavelength-calibrated spectra from any NIRSpec exposure, regardless of observing mode or aperture used. Optimizing the NIRSpec instrument model and deriving its final wavelength and astrometric calibration was one of the most crucial elements of the NIRSpec commissioning phase. Here, we describe the process of re-fitting the NIRSpec instrument model with in-orbit commissioning data, and present its final performance in terms of wavelength accuracy and astrometric calibration.

preprint2022arXiv

In-flight performance of the NIRSpec Micro Shutter Array

The NIRSpec instrument on the James Webb Space Telescope (JWST) brings the first multi-object spectrograph (MOS) into space, enabled by a programmable Micro Shutter Array (MSA) of ~250,000 individual apertures. During the 6-month Commissioning period, the MSA performed admirably, completing ~800 reconfigurations with an average success rate of ~96% for commanding shutters open in science-like patterns. We show that 82.5% of the unvignetted shutter population is usable for science, with electrical short masking now the primary cause of inoperable apertures. In response, we propose a plan to recheck existing shorts during nominal operations, which is expected to reduce the number of affected shutters. We also present a full assessment of the Failed Open and Failed Closed shutter populations, which both show a marginal increase in line with predictions from ground testing. We suggest an amendment to the Failed Closed shutter flagging scheme to improve flexibility for MSA configuration planning. Overall, the NIRSpec MSA performed very well during Commissioning, and the MOS mode was declared ready for science operations on schedule.

preprint2022arXiv

In-orbit Commissioning of the Near-Infrared Spectrograph on the James Webb Space Telescope

The Near-Infrared Spectrograph (NIRSpec) is one of the four focal plane instruments on the James Webb Space Telescope which was launched on Dec. 25, 2021. We present an overview of the as-run NIRSpec commissioning campaign, with particular emphasis on the sequence of activities that led to the verification of all hardware components of NIRSpec. We also discuss the mechanical, thermal, and operational performance of NIRSpec, as well as the readiness of all NIRSpec observing modes for use in the upcoming JWST science program.

preprint2016arXiv

A model-based approach to the spatial and spectral calibration of NIRSpec onboard JWST

Context: The NIRSpec instrument for the James Webb Space Telescope (JWST) can be operated in multiobject (MOS), long-slit, and integral field (IFU) mode with spectral resolutions from 100 to 2700. Its MOS mode uses about a quarter of a million individually addressable minislits for object selection, covering a field of view of $\sim$9 $\mathrm{arcmin}^2$. Aims: The pipeline used to extract wavelength-calibrated spectra from NIRSpec detector images relies heavily on a model of NIRSpec optical geometry. We demonstrate how dedicated calibration data from a small subset of NIRSpec modes and apertures can be used to optimize this parametric model to the necessary levels of fidelity. Methods: Following an iterative procedure, the initial fiducial values of the model parameters are manually adjusted and then automatically optimized, so that the model predicted location of the images and spectral lines from the fixed slits, the IFU, and a small subset of the MOS apertures matches their measured location in the main optical planes of the instrument. Results: The NIRSpec parametric model is able to reproduce the spatial and spectral position of the input spectra with high fidelity. The intrinsic accuracy (1-sigma, RMS) of the model, as measured from the extracted calibration spectra, is better than 1/10 of a pixel along the spatial direction and better than 1/20 of a resolution element in the spectral direction for all of the grating-based spectral modes. This is fully consistent with the corresponding allocation in the spatial and spectral calibration budgets of NIRSpec.