Researcher profile

Per Eklund

Per Eklund contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

P-type behavior of CrN thin films by control of point defects

We report the results of a combined experimental and theoretical study on nonstoichiometric CrN1+d thin films grown by reactive magnetron sputtering on c-plane sapphire, MgO (100) and LaAlO3 (100) substrates in a Ar/N2 gas mixture using different percentage of N2. There is a transition from n-type to p-type behavior in the layers as a function of nitrogen concentration varying from 48 at. % to 52 at. % in CrN films. The compositional change follows a similar trend for all substrates, with a N/Cr ratio increasing from approximately 0.7 to 1.06-1.10 by increasing percentage of N2 in the gas flow ratio. As a result of the change in stoichiometry, the lattice parameter and the Seebeck coefficient increase together with the increase of N in CrN1+d; in particular, the Seebeck value coefficient transitions from -50 uV.K-1 for CrN0.97 to +75 uV.K-1 for CrN1.1. Density functional theory calculations show that Cr vacancies can account for the change in Seebeck coefficient, since they push the Fermi level down in the valence band, whereas N interstitial defects in the form of N2 dumbbells are needed to explain the increasing lattice parameter. Calculations including both types of defects, which have a strong tendency to bind together, reveal a slight increase in the lattice parameter and a simultaneous formation of holes in the valence band. To explain the experimental trends, we argue that both Cr vacancies and N2 dumbbells, possibly in combined configurations, are present in the films. We demonstrate the possibility of controlling the semiconducting behavior of CrN with intrinsic defects from n- to p-type, opening possibilities to integrate this compound in energy-harvesting thermoelectric devices.

preprint2022arXiv

Solid-state Janus nanoprecipitation enables amorphous-like heat conduction in crystalline Mg3Sb2-based thermoelectric materials

Solid-state precipitation can be used to tailor materials properties, ranging from ferromagnets and catalysts to mechanical strengthening and energy storage. Thermoelectric properties can be modified by precipitation to enhance phonon scattering while retaining charge-carrier transmission. Here, we uncover unconventional dual Janus-type nanoprecipitates in Mg3Sb1.5Bi0.5 formed by side-by-side Bi- and Ge-rich appendages, in contrast to separate nanoprecipitate formation. These Janus nanoprecipitates result from local co-melting of Bi and Ge during sintering, enabling an amorphous-like lattice thermal conductivity. A precipitate size effect on phonon scattering is observed due to the balance between alloy-disorder and nanoprecipitate scattering. The thermoelectric figure-of-merit ZT reaches 0.6 near room temperature and 1.6 at 773 K. The Janus nanoprecipitation can be introduced into other materials and may act as a general property-tailoring mechanism.

preprint2021arXiv

An upgraded ultra-high vacuum magnetron-sputtering system for high-versatility and software-controlled deposition

Magnetron sputtering is a widely used physical vapor deposition technique. Reactive sputtering is used for the deposition of, e.g, oxides, nitrides and carbides. In fundamental research, versatility is essential when designing or upgrading a deposition chamber. Furthermore, automated deposition systems are the norm in industrial production, but relatively uncommon in laboratory-scale systems used primarily for fundamental research. Combining automatization and computerized control with the required versatility for fundamental research constitutes a challenge in designing, developing, and upgrading laboratory deposition systems. The present article provides a detailed description of the design of a lab-scale deposition chamber for magnetron sputtering used for the deposition of metallic, oxide, nitride and oxynitride films with automated controls, dc or pulsed bias, and combined with a coil to enhance the plasma density near the substrate. LabVIEW software (provided as Supplementary Information) has been developed for a high degree of computerized or automated control of hardware and processes control and logging of process details.

preprint2021arXiv

Characterization and identification of Au pathfinder minerals from an artisanal mine site using X-ray diffraction

Gold-associated pathfinder minerals have been investigated by identifying host minerals of Au for samples collected from an artisanal mining site near a potential gold mine (Kubi Gold Project) in Dunkwa-On-Offin in the central region of Ghana. We find that for each composition of Au powder (impure) and the residual black hematite/magnetite sand that remains after gold panning, there is a unique set of associated diverse indicator minerals. These indicator minerals are identified as SiO2 (quartz), Fe3O4 (magnetite), and Fe2O3 (hematite), while contributions from pyrite, arsenopyrites, iridosmine, scheelite, tetradymite, garnet, gypsum, and other sulfate materials are insignificant. This constitutes a confirmative identification of Au pathfinding minerals in this particular mineralogical area. The findings suggest that X-ray diffraction could also be applied in other mineralogical sites to aid in identifying indicator minerals of Au and the location of ore bodies at reduced environmental and exploration costs.

preprint2021arXiv

Electron-Phonon Coupling and Quantum Correction to Topological Magnetoconductivity in Bi2GeTe4

We report on structure, vibrational properties and weak-antilocalization-(WAL-) induced quantum correction to magnetoconductivity in single crystal Bi2GeTe4. Surface band structure calculations show a single Dirac cone corresponding to topological surface states in Bi2GeTe4. An estimated phase coherence length, l_ϕ ~ 143 nm and prefactor α ~ - 1.54 from Hikami-Larkin-Nagaoka fitting of magnetoconductivity describe the quantum correction to conductivity. An anomalous temperature dependence of A1g Raman modes confirms enhanced electron-phonon interactions. Our results establish the involvement of vibrations of Bi-Te with existence of topological surface states and WAL in Bi2GeTe4.

preprint2020arXiv

Halogenated MXenes with Electrochemically Active Terminals for High Performance Zinc Ion Batteries

The class of two-dimensional metal carbides and nitrides known as MXenes offer a distinct manner of property tailoring for a wide range of applications. The ability to tune the surface chemistry for expanding the property space of MXenes is thus an important topic, although experimental exploration of new surface terminals remains a challenge. Here, we synthesized Ti3C2 MXene with unitary, binary and ternary halogen terminals, e.g. -Cl, -Br, -I, -BrI and -ClBrI, to investigate the effect of surface chemistry on the properties of MXenes. The electrochemical activity of Br and I element result in the extraordinary electrochemical performance of the MXenes as cathodes for aqueous zinc ion batteries. The -Br and -I containing MXenes, e.g. Ti3C2Br2 and Ti3C2I2, exhibit distinct discharge platforms with considerable capacities of 97.6 mAh g-1 and 135 mAh g-1. Ti3C2(BrI) and Ti3C2(ClBrI) exhibit dual discharge platforms with capacities of 117.2 mAh g-1 and 106.7 mAh g-1. In contrast, the previously discovered MXenes Ti3C2Cl2 and Ti3C2(OF) exhibit no discharge platforms, and only ~50% of capacities and energy densities of Ti3C2Br2. These results emphasize the effectiveness of the Lewis-acidic-melt etching route for tuning the surface chemistry of MXenes, and also show promise for expanding the MXene family towards various applications.

preprint2019arXiv

Multielemental single-atom-thick A layers in nanolaminated V2(Sn, A)C (A=Fe, Co, Ni, Mn) for tailoring magnetic properties

Tailoring of individual single-atom-thick layers in nanolaminated materials offers atomic-level control over material properties. Nonetheless, multielement alloying in individual atomic layers in nanolaminates is largely unexplored. Here, we report a series of inherently nanolaminated V2(A'xSn1-x)C (A'=Fe, Co, Ni and Mn, and combinations thereof, with x=1/3) synthesized by an alloy-guided reaction. The simultaneous occupancy of the four magnetic elements and Sn, the individual single-atom-thick A layers in the compound constitute high-entropy-alloy analogues, two-dimensional in the sense that the alloying exclusively occurs in the A layers. V2(A'xSn1-x)C exhibit distinct ferromagnetic behavior that can be compositionally tailored from the multielement A-layer alloying. This two-dimensional alloying provides a structural-design route with expanded chemical space for discovering materials and exploit properties.