Researcher profile

Peder Larson

Peder Larson contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Development of Conditional Random Field Insert for UNet-based Zonal Prostate Segmentation on T2-Weighted MRI

Purpose: A conventional 2D UNet convolutional neural network (CNN) architecture may result in ill-defined boundaries in segmentation output. Several studies imposed stronger constraints on each level of UNet to improve the performance of 2D UNet, such as SegNet. In this study, we investigated 2D SegNet and a proposed conditional random field insert (CRFI) for zonal prostate segmentation from clinical T2-weighted MRI data. Methods: We introduced a new methodology that combines SegNet and CRFI to improve the accuracy and robustness of the segmentation. CRFI has feedback connections that encourage the data consistency at multiple levels of the feature pyramid. On the encoder side of the SegNet, the CRFI combines the input feature maps and convolution block output based on their spatial local similarity, like a trainable bilateral filter. For all networks, 725 2D images (i.e., 29 MRI cases) were used in training; while, 174 2D images (i.e., 6 cases) were used in testing. Results: The SegNet with CRFI achieved the relatively high Dice coefficients (0.76, 0.84, and 0.89) for the peripheral zone, central zone, and whole gland, respectively. Compared with UNet, the SegNet+CRFIs segmentation has generally higher Dice score and showed the robustness in determining the boundaries of anatomical structures compared with the SegNet or UNet segmentation. The SegNet with a CRFI at the end showed the CRFI can correct the segmentation errors from SegNet output, generating smooth and consistent segmentation for the prostate. Conclusion: UNet based deep neural networks demonstrated in this study can perform zonal prostate segmentation, achieving high Dice coefficients compared with those in the literature. The proposed CRFI method can reduce the fuzzy boundaries that affected the segmentation performance of baseline UNet and SegNet models.

preprint2020arXiv

Iterative Motion Compensation reconstruction ultra-short TE(iMoCo UTE) for high resolution free breathing pulmonary MRI

Purpose, To develop a high scanning efficiency, motion corrected imaging strategy for free-breathing pulmonary MRI by combining a motion compensation reconstruction with a UTE acquisition, called iMoCo UTE. Methods, An optimized golden angle ordering radial UTE sequence was used to continuously acquire data for 5 minutes. All readouts were grouped to different respiratory motion states based on self-navigator signals, then motion resolved data was reconstructed by XD Golden angle RAdial Sparse Parallel reconstruction (XD GRASP). One state from the motion resolved images was selected as a reference, and motion fields from the other states to the reference were derived via non-rigid registration. Finally, all motion resolved data and motion fields were reconstructed by using an iterative motion compensation reconstruction with a total generalized variation sparse constraint. Results, The iMoCo UTE strategy was evaluated in volunteers and non-sedated pediatric patient(4-6 y/o) studies. Images reconstructed with iMoCo UTE provided sharper anatomical lung structures, and higher apparent SNR and CNR, compared to using other motion correction strategies, such as soft-gating, motion resolved reconstruction, and non-rigid motion compensation(MoCo). iMoCo UTE also showed promising results in an infant study. Conclusions, The proposed iMoCo UTE combines self-navigation, motion modeling, and a compressed sensing reconstruction to increase scan efficiency, SNR, and reduce respiratory motion in lung MRI. This proposed strategy shows improvements in free breathing lung MRI scans, especially in very challenging application situations, such as pediatric MRI studies.