Source author record

Paul Williams

Paul Williams appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
8topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Enhancing Early Lung Cancer Detection on Chest Radiographs with AI-assistance: A Multi-Reader Study

Objectives: The present study evaluated the impact of a commercially available explainable AI algorithm in augmenting the ability of clinicians to identify lung cancer on chest X-rays (CXR). Design: This retrospective study evaluated the performance of 11 clinicians for detecting lung cancer from chest radiographs, with and without assistance from a commercially available AI algorithm (red dot, Behold.ai) that predicts suspected lung cancer from CXRs. Clinician performance was evaluated against clinically confirmed diagnoses. Setting: The study analysed anonymised patient data from an NHS hospital; the dataset consisted of 400 chest radiographs from adult patients (18 years and above) who had a CXR performed in 2020, with corresponding clinical text reports. Participants: A panel of readers consisting of 11 clinicians (consultant radiologists, radiologist trainees and reporting radiographers) participated in this study. Main outcome measures: Overall accuracy, sensitivity, specificity and precision for detecting lung cancer on CXRs by clinicians, with and without AI input. Agreement rates between clinicians and performance standard deviation were also evaluated, with and without AI input. Results: The use of the AI algorithm by clinicians led to an improved overall performance for lung tumour detection, achieving an overall increase of 17.4% of lung cancers being identified on CXRs which would have otherwise been missed, an overall increase in detection of smaller tumours, a 24% and 13% increased detection of stage 1 and stage 2 lung cancers respectively, and standardisation of clinician performance. Conclusions: This study showed great promise in the clinical utility of AI algorithms in improving early lung cancer diagnosis and promoting health equity through overall improvement in reader performances, without impacting downstream imaging resources.

preprint2016arXiv

Active Fault Tolerant Flight Control System Design

In this paper we investigate the design of an active fault tolerant control system applicable to autonomous flight. The system comprises a nonlinear model predictive based controller integrated with an unscented Kalman filter for fault detection and identification. We apply the fault tolerant control system design to a generic aircraft model, and simulate a failed engine scenario. The results show that the system correctly identifies the fault within seconds of occurrence and updates the nonlinear model predictive controller which is then able to reallocate control authority to the healthy actuators based upon up to date fault information.

preprint2016arXiv

Active Fault Tolerant Flight Control System Design - A UAV Case Study

Fault tolerance is achieved through multiply redundant hardware systems in large civil aircraft. This means of achieving fault tolerance is infeasible for small compact unmanned aerial vehicles. In this paper we apply a fault tolerant control system which exploits analytical redundancy rather than hardware redundancy to an actual UAV model currently in operation via model-in-the-loop simulation. The fault tolerant control system comprises a nonlinear model predictive controller integrated with an unscented Kalman filter for fault detection and identification. The results show that our fault tolerant control system design is able to identify engine failure within seconds of fault occurrence and distribute control authority to the healthy actuators to maintain safe flight.

preprint2016arXiv

Designing a Nonlinear Model Predictive Controller for Fault Tolerant Flight Control

This paper describes the design process for developing a nonlinear model predictive controller for fault tolerant flight control. After examining and implementing a number of numerical techniques, this paper identifies pseudospectral discretisation as the most suitable for this design. Applying the controller to a 2D robot model shows that the nonlinear controller performs much better than the linear controller, especially in the closed loop scenario. Assuming fault detection information, applying the technique to the longitudinal motion of a generic aircraft model shows the design to be eminently suitable for flight control.

preprint2016arXiv

Instrumental performance and results from testing of the BLAST-TNG receiver, submillimeter optics, and MKID arrays

Polarized thermal emission from interstellar dust grains can be used to map magnetic fields in star forming molecular clouds and the diffuse interstellar medium (ISM). The Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry (BLASTPol) flew from Antarctica in 2010 and 2012 and produced degree-scale polarization maps of several nearby molecular clouds with arcminute resolution. The success of BLASTPol has motivated a next-generation instrument, BLAST-TNG, which will use more than 3000 linear polarization sensitive microwave kinetic inductance detectors (MKIDs) combined with a 2.5m diameter carbon fiber primary mirror to make diffraction-limited observations at 250, 350, and 500 $μ$m. With 16 times the mapping speed of BLASTPol, sub-arcminute resolution, and a longer flight time, BLAST-TNG will be able to examine nearby molecular clouds and the diffuse galactic dust polarization spectrum in unprecedented detail. The 250 $μ$m detector array has been integrated into the new cryogenic receiver, and is undergoing testing to establish the optical and polarization characteristics of the instrument. BLAST-TNG will demonstrate the effectiveness of kilo-pixel MKID arrays for applications in submillimeter astronomy. BLAST-TNG is scheduled to fly from Antarctica in December 2017 for 28 days and will be the first balloon-borne telescope to offer a quarter of the flight for "shared risk" observing by the community.