Source author record

Paul Colas

Paul Colas appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

10works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2023arXiv

The International Linear Collider: Report to Snowmass 2021

The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This document brings the story of the ILC up to date, emphasizing its strong physics motivation, its readiness for construction, and the opportunity it presents to the US and the global particle physics community.

preprint2022arXiv

MPGDs for TPCs at future lepton colliders

This submission will focus on advancements and advantages of Micro Pattern Gas Detector (MPGD) technologies and their applications to the construction of a dedicated Time Projection Chamber (TPC) that can serve as an excellent main tracker for any multipurpose detector that can be foreseen to operate at a future lepton collider. The first portion of the report will be the executive summary. It will be followed by sections detailing the applications of MPGDs specifically to the construction of the LCTPC for the ILD at ILC, for a possible upgrade of the Belle II detector at SuperKEKB and for the design of a TPC for a detector at CEPC. MPGD technologies offer synergies with other detector R&D and several application domains; a few examples will be provided in the context of the ongoing Snowmass long range planning exercise in the USA. Links to industrial partnership and work with institutions in the USA will be highlighted when appropriate.

preprint2020arXiv

Numerical study of track distortion in the Large Prototype TPC with end-plate based on bulk Micromegas

The present $\mathrm{R}\&\mathrm{D}$ activities for the International Large Detector Time Projection Chamber (ILD-TPC) concern the adoption of the micro pattern devices for the gaseous amplification stage. Seven Micromegas modules which are commissioned on the end-plate of a Large Prototype TPC (LPTPC) at DESY, were tested with a 5 GeV electron beam, under a 1 T magnetic field. During experiments, reduced signal sensitivity as well as distortion in the reconstructed track was observed at the boundaries of these modules. Electrostatic field inhomogeneity near the module boundaries was considered to be the possible major reason behind these observations. In the present work, this hypothesis has been explored using the Garfield simulation framework. It has been possible to contain the computational complexity of the problem with suitable simplifications. Qualitative and quantitative agreements with experimental results have been achieved. Possibility of mitigating the problems has been proposed using the same simulation framework.

preprint2016arXiv

A Time Projection Chamber with GEM-Based Readout

For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1 T solenoidal field and read out with three independent GEM-based readout modules, are reported. The TPC was exposed to a 6 GeV electron beam at the DESY II synchrotron. The efficiency for reconstructing hits, the measurement of the drift velocity, the space point resolution and the control of field inhomogeneities are presented.

preprint2016arXiv

First measurement of polarisation asymmetry of a gamma-ray beam between 1.74 to 74 MeV with the HARPO TPC

Current $γ$-ray telescopes suffer from a gap in sensitivity in the energy range between 100keV and 100MeV, and no polarisation measurement has ever been done on cosmic sources above 1MeV. Past and present e$^+$e$^-$ pair telescopes are limited at lower energies by the multiple scattering of electrons in passive tungsten converter plates. This results in low angular resolution, and, consequently, a drop in sensitivity to point sources below 1GeV. The polarisation information, which is carried by the azimuthal angle of the conversion plane, is lost for the same reasons. HARPO (Hermetic ARgon POlarimeter) is an R\&D program to characterise the operation of a gaseous detector (a Time Projection Chamber or TPC) as a high angular-resolution and sensitivity telescope and polarimeter for $γ$ rays from cosmic sources. It represents a first step towards a future space instrument in the MeV-GeV range. We built and characterised a 30cm cubic demonstrator [SPIE 91441M], and put it in a polarised $γ$-ray beam at the NewSUBARU accelerator in Japan. Data were taken at photon energies from 1.74MeV to 74MeV, and with different polarisation configurations. We describe the experimental setup in beam. We then describe the software we developed to reconstruct the photon conversion events, with special focus on low energies. We also describe the thorough simulation of the detector used to compare results. Finally we will present the performance of the detector as extracted from this analysis and preliminary measurements of the polarisation asymmetry. This beam-test qualification of a gas TPC prototype in a $γ$-ray beam could open the way to high-performance $γ$-ray astronomy and polarimetry in the MeV-GeV energy range in the near future.

preprint2016arXiv

Investigation of Ion Backflow in Bulk Micromegas Detectors

The operation of gas detectors is often limited by secondary effects, originating from avalanche-induced photons and ions. Ion backflow is one of the effects limiting the operation of a gas detector at high flux, by giving rise to space charge which disturbs the electric field locally. For the Micromegas detector, a large fraction of the secondary positive ions created in the avalanche can be stopped at the micro-mesh. The present work involves measurements of the ion backflow fraction (using an experimental setup comprising of two drift planes) in bulk Micromegas detectors as a function of detector design parameters. These measured characteristics have also been compared in detail to numerical simulations using the Garfield framework that combines packages such as neBEM, Magboltz and Heed. Further, the effect of using a second micro-mesh on ion backflow and other parameters has been studied numerically.

preprint2016arXiv

Performance Studies of Bulk Micromegas of Different Design Parameters

The present work involves the comparison of various bulk Micromegas detectors having different design parameters. Six detectors with amplification gaps of $64,~128,~192,~220 ~μ\mathrm{m}$ and mesh hole pitch of $63,~78 ~μ\mathrm{m}$ were tested at room temperature and normal gas pressure. Two setups were built to evaluate the effect of the variation of the amplification gap and mesh hole pitch on different detector characteristics. The gain, energy resolution and electron transmission of these Micromegas detectors were measured in Argon-Isobutane (90:10) gas mixture while the measurements of the ion backflow were carried out in P10 gas. These measured characteristics have been compared in detail to the numerical simulations using the Garfield framework that combines packages such as neBEM, Magboltz and Heed.

preprint2015arXiv

HARPO: beam characterization of a TPC for gamma-ray polarimetry and high angular-resolution astronomy in the MeV-GeV range

A time projection chamber (TPC) can be used to measure the polarization of gamma rays with excellent angular precision and sensitivity in the MeV-GeV energy range through the conversion of photons to e+e- pairs. The Hermetic ARgon POlarimeter (HARPO) prototype was built to demonstrate this concept. It was recently tested in the polarized photon beam at the NewSUBARU facility in Japan. We present this data-taking run, which demonstrated the excellent performance of the HARPO TPC.

preprint2013arXiv

Comparison of Bulk Micromegas with Different Amplification Gaps

The bulk Micromegas detector is considered to be a promising candidate for building TPCs for several future experiments including the projected linear collider. The standard bulk with a spacing of 128 micron has already established itself as a good choice for its performances in terms of gas gain uniformity, energy and space point resolution, and its capability to efficiently pave large readout surfaces with minimum dead zone. The present work involves the comparison of this standard bulk with a relatively less used bulk Micromegas detector having a larger amplification gap of 192 micron. Detector gain, energy resolution and electron transparency of these Micromegas have been measured under different conditions in various argon based gas mixtures to evaluate their performance. These measured characteristics have also been compared in detail to numerical simulations using the Garfield framework that combines packages such as neBEM, Magboltz and Heed. Further, we have carried out another numerical study to determine the effect of dielectric spacers on different detector features. A comprehensive comparison of the two detectors has been presented and analyzed in this work.