Source author record

P. Rubinov

P. Rubinov appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

31works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

31 published item(s)

preprint2022arXiv

Electronics for Fast Timing

Picosecond-level timing will be an important component of the next generation of particle physics detectors. The ability to add a 4$^{th}$ dimension to our measurements will help address the increasing complexity of events at hadron colliders and provide new tools for precise tracking and calorimetry for all experiments. Detectors are described in detail on other whitepapers. In this note, we address challenges in electronics design for the new generations of fast timing detectors

preprint2022arXiv

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons

The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1 cm$^2$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.

preprint2016arXiv

A New Proton CT Scanner

The design, construction, and preliminary testing of a second generation proton CT scanner is presented. All current treatment planning systems at proton therapy centers use X-ray CT as the primary imaging modality for treatment planning to calculate doses to tumor and healthy tissues. One of the limitations of X-ray CT is in the conversion of X-ray attenuation coefficients to relative (proton) stopping powers, or RSP. This results in more proton range uncertainty, larger target volumes and therefore, more dose to healthy tissues. To help improve this, we present a novel scanner capable of high dose rates, up to 2~MHz, and large area coverage, 20~x~24~cm$^2$, for imaging an adult head phantom and reconstructing more accurate RSP values.

preprint2016arXiv

Calibration and GEANT4 Simulations of the Phase II Proton Compute Tomography (pCT) Range Stack Detector

Northern Illinois University in collaboration with Fermi National Accelerator Laboratory (FNAL) and Delhi University has been designing and building a proton CT scanner for applications in proton treatment planning. The Phase II proton CT scanner consists of eight planes of tracking detectors with two X and two Y coordinate measurements both before and after the patient. In addition, a range stack detector consisting of a stack of thin scintillator tiles, arranged in twelve eight-tile frames, is used to determine the water equivalent path length (WEPL) of each track through the patient. The X-Y coordinates and WEPL are required input for image reconstruction software to find the relative (proton) stopping powers (RSP) value of each voxel in the patient and generate a corresponding 3D image. In this Note we describe tests conducted in 2015 at the proton beam at the Central DuPage Hospital in Warrenville, IL, focusing on the range stack calibration procedure and comparisons with the GEANT~4 range stack simulation.

preprint2016arXiv

Near-infrared scintillation of liquid argon

Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $μ$m < $λ$; < 1.5$μ$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

preprint2016arXiv

Pion contamination in the MICE muon beam

The international Muon Ionization Cooling Experiment (MICE) will perform a systematic investigation of ionization cooling with muon beams of momentum between 140 and 240\,MeV/c at the Rutherford Appleton Laboratory ISIS facility. The measurement of ionization cooling in MICE relies on the selection of a pure sample of muons that traverse the experiment. To make this selection, the MICE Muon Beam is designed to deliver a beam of muons with less than $\sim$1\% contamination. To make the final muon selection, MICE employs a particle-identification (PID) system upstream and downstream of the cooling cell. The PID system includes time-of-flight hodoscopes, threshold-Cherenkov counters and calorimetry. The upper limit for the pion contamination measured in this paper is $f_π< 1.4\%$ at 90\% C.L., including systematic uncertainties. Therefore, the MICE Muon Beam is able to meet the stringent pion-contamination requirements of the study of ionization cooling.

preprint2015arXiv

Development of a proton Computed Tomography Detector System

Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantageous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

preprint2015arXiv

Electron-Muon Ranger: performance in the MICE Muon Beam

The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires an efficient particle-identification (PID) system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter that forms part of the PID system and tags muons that traverse the cooling channel without decaying. The detector is capable of identifying electrons with an efficiency of 98.6%, providing a purity for the MICE beam that exceeds 99.8%. The EMR also proved to be a powerful tool for the reconstruction of muon momenta in the range 100-280 MeV/$c$.

preprint2015arXiv

Hamamatsu PMT R7056 Study for the Extinction Monitoring System of the Mu2e Experiment at Fermilab

The Mu2e experiment at Fermilab proposes to search for the coherent neutrino-less conversion of muons to electrons in the presence of a nucleus. The experimental signature for an aluminum target is an isolated 105 MeV electron exiting the stopping target no earlier than ~700 ns after the pulse of proton beam hits the production target. Any protons that hit the production target in between the pulses can lead to fake conversion electrons during the measurement period. We define the beam extinction as the ratio of the number of protons striking the production target between pulses to the number striking the target during the pulses. It has been established that an extinction of approximately 10-10 is required to reduce the backgrounds to an acceptable level. It would be desirable to measure the extinction of the beam coming out of the accelerator in a minute or less. Studies for the fast extinction monitor based on Hamamatsu PMT R7056 is the subject of this presentation.

preprint2015arXiv

MINERvA neutrino detector response measured with test beam data

The MINERvA collaboration operated a scaled-down replica of the solid scintillator tracking and sampling calorimeter regions of the MINERvA detector in a hadron test beam at the Fermilab Test Beam Facility. This article reports measurements with samples of protons, pions, and electrons from 0.35 to 2.0 GeV/c momentum. The calorimetric response to protons, pions, and electrons are obtained from these data. A measurement of the parameter in Birks' law and an estimate of the tracking efficiency are extracted from the proton sample. Overall the data are well described by a Geant4-based Monte Carlo simulation of the detector and particle interactions with agreements better than 4%, though some features of the data are not precisely modeled. These measurements are used to tune the MINERvA detector simulation and evaluate systematic uncertainties in support of the MINERvA neutrino cross section measurement program.

preprint2015arXiv

Mu2e Technical Design Report

The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the preliminary design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2 approval.

preprint2015arXiv

Performance of Scintillator Counters with Silicon Photomultiplier Readout

The performance of scintillator counters with embedded wavelength-shifting fibers has been measured in the Fermilab Meson Test Beam Facility using 120 GeV protons. The counters were extruded with a titanium dioxide surface coating and two channels for fibers at the Fermilab NICADD facility. Each fiber end is read out by a 2*2 mm^2 silicon photomultiplier. The signals were amplified and digitized by a custom-made front-end electronics board. Combinations of 5*2 cm^2 and 6*2 cm^2 extrusion profiles with 1.4 and 1.8 mm diameter fibers were tested. The design is intended for the cosmic-ray veto detector for the Mu2e experiment at Fermilab. The light yield as a function of the transverse and longitudinal position of the beam will be given.

preprint2014arXiv

Light sterile neutrino sensitivity at the nuSTORM facility

A facility that can deliver beams of electron and muon neutrinos from the decay of a stored muon beam has the potential to unambiguously resolve the issue of the evidence for light sterile neutrinos that arises in short-baseline neutrino oscillation experiments and from estimates of the effective number of neutrino flavors from fits to cosmological data. In this paper, we show that the nuSTORM facility, with stored muons of 3.8 GeV/c $\pm$ 10%, will be able to carry out a conclusive muon neutrino appearance search for sterile neutrinos and test the LSND and MiniBooNE experimental signals with 10$σ$ sensitivity, even assuming conservative estimates for the systematic uncertainties. This experiment would add greatly to our knowledge of the contribution of light sterile neutrinos to the number of effective neutrino flavors from the abundance of primordial helium production and from constraints on neutrino energy density from the cosmic microwave background. The appearance search is complemented by a simultaneous muon neutrino disappearance analysis that will facilitate tests of various sterile neutrino models.

preprint2013arXiv

Characterisation of the muon beams for the Muon Ionisation Cooling Experiment

A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.5--2.3 πmm-rad horizontally and 0.6--1.0 πmm-rad vertically, a horizontal dispersion of 90--190 mm and momentum spreads of about 25 MeV/c. There is reasonable agreement between the measured parameters of the beams and the results of simulations. The beams are found to meet the requirements of MICE.

preprint2013arXiv

Combination of CDF and D0 W-Boson Mass Measurements

We summarize and combine direct measurements of the mass of the $W$ boson in $\sqrt{s} = 1.96 \text{TeV}$ proton-antiproton collision data collected by CDF and D0 experiments at the Fermilab Tevatron Collider. Earlier measurements from CDF and D0 are combined with the two latest, more precise measurements: a CDF measurement in the electron and muon channels using data corresponding to $2.2 \mathrm{fb}^{-1}$ of integrated luminosity, and a D0 measurement in the electron channel using data corresponding to $4.3 \mathrm{fb}^{-1}$ of integrated luminosity. The resulting Tevatron average for the mass of the $W$ boson is $\MW = 80\,387 \pm 16 \text{MeV}$. Including measurements obtained in electron-positron collisions at LEP yields the most precise value of $\MW = 80\,385 \pm 15 \text{MeV}$.

preprint2013arXiv

Design, Calibration, and Performance of the MINERvA Detector

The MINERvA experiment is designed to perform precision studies of neutrino-nucleus scattering using $ν_μ$ and ${\barν}_μ$ neutrinos incident at 1-20 GeV in the NuMI beam at Fermilab. This article presents a detailed description of the \minerva detector and describes the {\em ex situ} and {\em in situ} techniques employed to characterize the detector and monitor its performance. The detector is comprised of a finely-segmented scintillator-based inner tracking region surrounded by electromagnetic and hadronic sampling calorimetry. The upstream portion of the detector includes planes of graphite, iron and lead interleaved between tracking planes to facilitate the study of nuclear effects in neutrino interactions. Observations concerning the detector response over sustained periods of running are reported. The detector design and methods of operation have relevance to future neutrino experiments in which segmented scintillator tracking is utilized.

preprint2013arXiv

Neutrinos from Stored Muons nuSTORM: Expression of Interest

The nuSTORM facility has been designed to deliver beams of electron and muon neutrinos from the decay of a stored muon beam with a central momentum of 3.8 GeV/c and a momentum spread of 10%. The facility is unique in that it will: serve the future long- and short-baseline neutrino-oscillation programmes by providing definitive measurements of electron-neutrino- and muon-neutrino-nucleus cross sections with percent-level precision; allow searches for sterile neutrinos of exquisite sensitivity to be carried out; and constitute the essential first step in the incremental development of muon accelerators as a powerful new technique for particle physics. Of the world's proton-accelerator laboratories, only CERN and FNAL have the infrastructure required to mount nuSTORM. Since no siting decision has yet been taken, the purpose of this Expression of Interest (EoI) is to request the resources required to: investigate in detail how nuSTORM could be implemented at CERN; and develop options for decisive European contributions to the nuSTORM facility and experimental programme wherever the facility is sited. The EoI defines a two-year programme culminating in the delivery of a Technical Design Report.

preprint2012arXiv

Combination of CDF and D0 measurements of the W boson helicity in top quark decays

We report the combination of recent measurements of the helicity of the W boson from top quark decay by the CDF and D0 collaborations, based on data samples corresponding to integrated luminosities of 2.7 - 5.4 fb^-1 of ppbar collisions collected during Run II of the Fermilab Tevatron Collider. Combining measurements that simultaneously determine the fractions of W bosons with longitudinal (f0) and right-handed (f+) helicities, we find f0 = 0.722 \pm 0.081 [\pm 0.062 (stat.) \pm 0.052 (syst.)] and f+ = -0.033 \pm 0.046 [\pm 0.034 (stat.) \pm 0.031 (syst.)]. Combining measurements where one of the helicity fractions is fixed to the value expected in the standard model, we find f0 = 0.682 \pm 0.057 [\pm 0.035 (stat.) \pm 0.046 (syst.)] and f+ = -0.015\pm0.035 [\pm 0.018 (stat.) \pm 0.030 (syst.)]. The results are consistent with standard model expectations.

preprint2012arXiv

Combination of the top-quark mass measurements from the Tevatron collider

The top quark is the heaviest known elementary particle, with a mass about 40 times larger than the mass of its isospin partner, the bottom quark. It decays almost 100% of the time to a $W$ boson and a bottom quark. Using top-antitop pairs at the Tevatron proton-antiproton collider, the CDF and {\dzero} collaborations have measured the top quark's mass in different final states for integrated luminosities of up to 5.8 fb$^{-1}$. This paper reports on a combination of these measurements that results in a more precise value of the mass than any individual decay channel can provide. It describes the treatment of the systematic uncertainties and their correlations. The mass value determined is $173.18 \pm 0.56 \thinspace ({\rm stat}) \pm 0.75 \thinspace ({\rm syst})$ GeV or $173.18 \pm 0.94$ GeV, which has a precision of $\pm 0.54%$, making this the most precise determination of the top quark mass.

preprint2012arXiv

Demonstration of Communication using Neutrinos

Beams of neutrinos have been proposed as a vehicle for communications under unusual circumstances, such as direct point-to-point global communication, communication with submarines, secure communications and interstellar communication. We report on the performance of a low-rate communications link established using the NuMI beam line and the MINERvA detector at Fermilab. The link achieved a decoded data rate of 0.1 bits/sec with a bit error rate of 1% over a distance of 1.035 km, including 240 m of earth.

preprint2012arXiv

Measurement of the differential cross section dσ/dt in elastic $p\bar{p}$ scattering at sqrt(s)=1.96 TeV

We present a measurement of the elastic differential cross section $dσ(p\bar{p}\rightarrow p\bar{p})/dt$ as a function of the four-momentum-transfer squared t. The data sample corresponds to an integrated luminosity of $\approx 31 nb^{-1}$ collected with the D0 detector using dedicated Tevatron $p\bar{p} $ Collider operating conditions at sqrt(s) = 1.96 TeV and covers the range $0.26 <|t|< 1.2 GeV^2$. For $|t|<0.6 GeV^2$, dσ/dt is described by an exponential function of the form $Ae^{-b|t|}$ with a slope parameter $ b = 16.86 \pm 0.10(stat) \pm 0.20(syst) GeV^{-2}$. A change in slope is observed at $|t| \approx 0.6 GeV^2$, followed by a more gradual |t| dependence with increasing values of |t|.

preprint2012arXiv

Measurement of the W boson helicity in top quark decays using 5.4 fb^-1 of ppbar collision data

We present a measurement of the helicity of the W boson produced in top quark decays using ttbar decays in the l+jets and dilepton final states selected from a sample of 5.4 fb^-1 of collisions recorded using the D0 detector at the Fermilab Tevatron ppbar collider. We measure the fractions of longitudinal and right-handed W bosons to be f_0 = 0.669 +- 0.102 [ +- 0.078 (stat.) +- 0.065 (syst.)] and f_+ = 0.023 +- 0.053 [+- 0.041 (stat.) +- 0.034 (syst.)], respectively. This result is consistent at the 98% level with the standard model. A measurement with f_0 fixed to the value from the standard model yields f_+ = 0.010 +- 0.037 [+- 0.022 (stat.) +- 0.030 (syst.) ].

preprint2012arXiv

Mu2e Conceptual Design Report

Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the conceptual design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-1 approval, which was granted July 11, 2012.

preprint2012arXiv

nuSTORM: Neutrinos from STORed Muons

The results of LSND and MiniBooNE, along with the recent papers on a possible reactor neutrino flux anomaly give tantalizing hints of new physics. Models beyond the neutrino-SM have been developed to explain these results and involve one or more additional neutrinos that are non-interacting or "sterile." Neutrino beams produced from the decay of muons in a racetrack-like decay ring provide a powerful way to study this potential new physics. In this Letter of Intent, we describe a facility, nuSTORM, "Neutrinos from STORed Muons," and an appropriate far detector for neutrino oscillation searches at short baseline. We present sensitivity plots that indicated that this experimental approach can provide over 10 sigma confirmation or rejection of the LSND/MinBooNE results. In addition we indicate how the facility can be used to make precision neutrino interaction cross section measurements important to the next generation of long-baseline neutrino oscillation experiments.

preprint2012arXiv

Search for pair production of the scalar top quark in muon+tau final states

We present a search for the pair production of scalar top quarks ($\tilde{t}_{1}$), the lightest supersymmetric partners of the top quarks, in $p\bar{p}$ collisions at a center-of-mass energy of 1.96 TeV, using data corresponding to an integrated luminosity of {7.3 $fb^{-1}$} collected with the \dzero experiment at the Fermilab Tevatron Collider. Each scalar top quark is assumed to decay into a $b$ quark, a charged lepton, and a scalar neutrino ($\tildeν$). We investigate final states arising from $\tilde{t}_{1} \bar{\tilde{t}_{1}} \rightarrow b\bar{b}μτ\tildeν \tildeν$ and $\tilde{t}_{1} \bar{\tilde{t}_{1}} \rightarrow b\bar{b}ττ\tildeν \tildeν$. With no significant excess of events observed above the background expected from the standard model, we set exclusion limits on this production process in the ($m_{\tilde{t}_{1}}$,$m_{\tildeν}$) plane.

preprint2012arXiv

The MINER$ν$A Data Acquisition System and Infrastructure

MINER$ν$A (Main INjector ExpeRiment $ν$-A) is a new few-GeV neutrino cross section experiment that began taking data in the FNAL NuMI (Fermi National Accelerator Laboratory Neutrinos at the Main Injector) beam-line in March of 2010. MINER$ν$A employs a fine-grained scintillator detector capable of complete kinematic characterization of neutrino interactions. This paper describes the MINER$ν$A data acquisition system (DAQ) including the read-out electronics, software, and computing architecture.

preprint2011arXiv

Precise measurement of the top quark mass in the dilepton channel at D0

We measure the top quark mass (mt) in ppbar collisions at a center of mass energy of 1.96 TeV using dilepton ttbar->W+bW-bbar->l+nubl-nubarbbar events, where l denotes an electron, a muon, or a tau that decays leptonically. The data correspond to an integrated luminosity of 5.4 fb-1 collected with the D0 detector at the Fermilab Tevatron Collider. We obtain mt = 174.0 +- 1.8(stat) +- 2.4(syst) GeV, which is in agreement with the current world average mt = 173.3 +- 1.1 GeV. This is currently the most precise measurement of mt in the dilepton channel.

preprint2010arXiv

Determination of the width of the top quark

We extract the total width of the top quark, Gamma_t, from the partial decay width Gamma(t -> W b) measured using the t-channel cross section for single top quark production and from the branching fraction B(t -> W b) measured in ttbar events using up to 2.3 fb^-1 of integrated luminosity collected by the D0 Collaboration at the Tevatron ppbar Collider. The result is Gamma_t = 1.99 +0.69 -0.55 GeV, which translates to a top-quark lifetime of tau_t = (3.3 +1.3 -0.9) x 10^-25 s. Assuming a high mass fourth generation b' quark and unitarity of the four-generation quark-mixing matrix, we set the first upper limit on |Vtb'| < 0.63 at 95% C.L.

preprint2010arXiv

Search for pair production of the scalar top quark in the electron-muon final state

We report the result of a search for the pair production of the lightest supersymmetric partner of the top quark ($\tilde{t}_1$) in $p\bar{p}$ collisions at a center-of-mass energy of 1.96 TeV at the Fermilab Tevatron collider corresponding to an integrated luminosity of 5.4 fb$^{-1}$. The scalar top quarks are assumed to decay into a $b$ quark, a charged lepton, and a scalar neutrino ($\tildeν$), and the search is performed in the electron plus muon final state. No significant excess of events above the standard model prediction is detected, and improved exclusion limits at the 95% C.L. are set in the the ($M_{\tilde{t}_1}$,$M_{\tildeν}$) mass plane.

preprint2010arXiv

The design, construction and performance of the MICE scintillating fibre trackers

Charged-particle tracking in the international Muon Ionisation Cooling Experiment (MICE) will be performed using two solenoidal spectrometers, each instrumented with a tracking detector based on 350 μm diameter scintillating fibres. The design and construction of the trackers is described along with the quality-assurance procedures, photon-detection system, readout electronics, reconstruction and simulation software and the data-acquisition system. Finally, the performance of the MICE tracker, determined using cosmic rays, is presented.