Source author record

P. Di Stefano

P. Di Stefano appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

13works
9topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2022arXiv

Constraints on dark matter-nucleon effective couplings in the presence of kinematically distinct halo substructures using the DEAP-3600 detector

DEAP-3600 is a single-phase liquid argon detector aiming to directly detect Weakly Interacting Massive Particles (WIMPs), located at SNOLAB (Sudbury, Canada). After analyzing data taken during the first year of operation, a null result was used to place an upper bound on the WIMP-nucleon spin-independent, isoscalar cross section. This study reinterprets this result within a Non-Relativistic Effective Field Theory framework, and further examines how various possible substructures in the local dark matter halo may affect these constraints. Such substructures are hinted at by kinematic structures in the local stellar distribution observed by the Gaia satellite and other recent astronomical surveys. These include the Gaia Sausage (or Enceladus), as well as a number of distinct streams identified in recent studies. Limits are presented for the coupling strength of the effective contact interaction operators $\mathcal{O}_1$, $\mathcal{O}_3$, $\mathcal{O}_5$, $\mathcal{O}_8$, and $\mathcal{O}_{11}$, considering isoscalar, isovector, and xenonphobic scenarios, as well as the specific operators corresponding to millicharge, magnetic dipole, electric dipole, and anapole interactions. The effects of halo substructures on each of these operators are explored as well, showing that the $\mathcal{O}_5$ and $\mathcal{O}_8$ operators are particularly sensitive to the velocity distribution, even at dark matter masses above 100 GeV/$c^2$.

preprint2022arXiv

First direct detection constraints on Planck-scale mass dark matter with multiple-scatter signatures using the DEAP-3600 detector

Dark matter particles with Planck-scale mass ($\simeq10^{19}\text{GeV}/c^2$) arise in well-motivated theories and could be produced by several cosmological mechanisms. Using a blind analysis of data collected over a 813 d live time with DEAP-3600, a 3.3 t single-phase liquid argon-based dark matter experiment at SNOLAB, a search for supermassive dark matter was performed, looking for multiple-scatter signals. No candidate signal events were observed, leading to the first direct detection constraints on Planck-scale mass dark matter. Leading limits constrain dark matter masses between $8.3\times10^{6}$ and $1.2\times10^{19} \text{GeV}/c^2$, and cross sections for scattering on $^{40}$Ar between $1.0\times10^{-23}$ and $2.4\times10^{-18} \text{cm}^2$. These are used to constrain two composite dark matter models.

preprint2021arXiv

SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms ("neutral bremsstrahlung", NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.

preprint2020arXiv

Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, $^{39}$Ar, a $β$ emitter of cosmogenic origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of $^{39}$Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly $γ$-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.

preprint2011arXiv

Results from a Low-Energy Analysis of the CDMS II Germanium Data

We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs) with masses below ~10 GeV/c^2. This analysis provides stronger constraints than previous CDMS II results for WIMP masses below 9 GeV/c^2 and excludes parameter space associated with possible low-mass WIMP signals from the DAMA/LIBRA and CoGeNT experiments.

preprint2011arXiv

Search for inelastic dark matter with the CDMS II experiment

Results are presented from a reanalysis of the entire five-tower data set acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis window was extended to a recoil energy of 150 keV, and an improved surface-event background-rejection cut was defined to increase the sensitivity of the experiment to the inelastic dark matter (iDM) model. Three dark matter candidates were found between 25 keV and 150 keV. The probability to observe three or more background events in this energy range is 11%. Because of the occurrence of these events the constraints on the iDM parameter space are slightly less stringent than those from our previous analysis, which used an energy window of 10-100 keV.

preprint2010arXiv

A detection system to measure muon-induced neutrons for direct Dark Matter searches

Muon-induced neutrons constitute a prominent background component in a number of low count rate experiments, namely direct searches for Dark Matter. In this work we describe a neutron detector to measure this background in an underground laboratory, the Laboratoire Souterrain de Modane. The system is based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of the EDELWEISS-II experiment for coincident muon detection. The system was installed in autumn 2008 and passed since then a number of commissioning tests proving its full functionality. The data-taking is continuously ongoing and a count rate of the order of 1 muon-induced neutron per day has been achieved.

preprint2010arXiv

Monitoring of the thermal neutron flux in the LSM underground laboratory

This paper describes precise measurements of the thermal neutron flux in the LSM underground laboratory in proximity of the EDELWEISS-II dark matter search experiment together with short measurements at various other locations. Monitoring of the flux of thermal neutrons is accomplished using a mobile detection system with low background proportional counter filled with $^3$He. On average 75 neutrons per day are detected with a background level below 1 count per day (cpd). This provides a unique possibility of a day by day study of variations of the neutron field in a deep underground site. The measured average 4$π$ neutron flux per cm$^{2}$ in the proximity of EDELWEISS-II is $Φ_{MB}=3.57\pm0.05^{stat}\pm0.27^{syst}\times 10^{-6}$ neutrons/sec. We report the first experimental observation that the point-to-point thermal neutron flux at LSM varies by more than a factor two.

preprint2009arXiv

A new high-background-rejection dark matter Ge cryogenic detector

A new design of a cryogenic germanium detector for dark matter search is presented, taking advantage of the coplanar grid technique of event localisation for improved background discrimination. Experiments performed with prototype devices in the EDELWEISS II setup at the Modane underground facility demonstrate the remarkably high efficiency of these devices for the rejection of low-energy $β$, approaching 10$^5$ . This opens the road to investigate the range beyond 10$^{-8}$ pb in the WIMP-nucleon collision cross-sections, as proposed in the EURECA project of a one-ton cryogenic detector mass.

preprint2009arXiv

First results of the EDELWEISS-II WIMP search using Ge cryogenic detectors with interleaved electrodes

The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months of continuous operation at the Laboratoire Souterrain de Modane have been achieved. The observation of one nuclear recoil candidate above 20 keV in an effective exposure of 144 kgd is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 1.0x10^-7 pb is excluded at 90%CL for a WIMP mass of 80 GeV/c2. This result demonstrates for the first time the very high background rejection capabilities of these simple and robust detectors in an actual WIMP search experiment.

preprint2007arXiv

Brittle fracture down to femto-Joules - and below

We analyze large sets of energy-release data created by stress-induced brittle fracture in a pure sapphire crystal at close to zero temperature where stochastic fluctuations are minimal. The waiting-time distribution follows that observed for fracture in rock and for earthquakes. Despite strong time correlations of the events and the presence of large-event precursors, simple prediction algorithms only succeed in a very weak probabilistic sense. We also discuss prospects for further cryogenic experiments reaching close to single-bond sensitivity and able to investigate the existence of a transition-stress regime.

preprint2001arXiv

Dark Matter Search in the Edelweiss Experiment

Preliminary results obtained with 320g bolometers with simultaneous ionization and heat measurements are described. After a few weeks of data taking, data accumulated with one of these detectors are beginning to exclude the upper part of the DAMA region. Prospects for the present run and the second stage of the experiment, EDELWEISS-II, using an innovative reversed cryostat allowing data taking with 100 detectors, are briefly described.

preprint2001arXiv

First Results of the EDELWEISS WIMP Search using a 320 g Heat-and-Ionization Ge Detector

The EDELWEISS collaboration has performed a direct search for WIMP dark matter using a 320 g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane. No nuclear recoils are observed in the fiducial volume in the 30-200 keV energy range during an effective exposure of 4.53 kg.days. Limits for the cross-section for the spin-independent interaction of WIMPs and nucleons are set in the framework of the Minimal Supersymmetric Standard Model (MSSM). The central value of the signal reported by the experiment DAMA is excluded at 90% CL.