Researcher profile

Ognjen Stanojev

Ognjen Stanojev contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2026arXiv

Effect of Dispatch Decisions on Small-Signal Stability of Converter-Dominated Power Systems

Small-signal stability of modern converter-dominated power systems has been the subject of extensive research, particularly from the perspective of device-level control design for grid-forming (GFM) and grid-following (GFL) converters. However, the influence of power flow variables on system stability has received limited attention. Conventional small-signal stability analyses are typically conducted at a specific operating point, emphasizing the selection of control or system design parameters while neglecting the sensitivity of stability characteristics to operating conditions. This paper seeks to bridge this gap by systematically investigating the impact of dispatch decisions on the small-signal stability of converter-based power systems. Our findings are first illustrated on a three-bus system and then validated on the standard IEEE 39-bus test system to demonstrate scalability. Across the test systems, we find that high-voltage capacitive operation of GFL converters limits its active power injection, whereas inductive operation permits higher injections, and it is generally preferable for the GFM converter to supply more active power.

preprint2022arXiv

Fast Mapping of Flexibility Regions at TSO-DSO Interfaces under Uncertainty

The gradual decommissioning of fossil fuel-driven power plants, that traditionally provide most operational flexibility in power systems, has led to more frequent grid stability issues. To compensate for the lack of flexible resources, Distributed Energy Resources (DERs) in distribution networks can be employed. To facilitate the use of DERs, the aggregated flexibility in a distribution grid is commonly represented on a $PQ$-plane displaying the feasible active and reactive power exchange with the upstream grid. This paper proposes a fast feasible operating region mapping mechanism that utilizes a linear power flow approximation in combination with linearized generator, current, and voltage constraints to construct a high-dimensional polyhedral feasible set of DER power injections. The obtained polytope is projected onto the $PQ$-plane using Fourier-Motzkin Elimination to represent the aggregate network flexibility. Additionally, uncertainty in DER generation is addressed using chance-constraints. Our analysis of a modified 33-bus IEEE test system demonstrates that the proposed method obtains more accurate approximations than former geometric methods and is ten times faster than the tested optimization-based method.

preprint2022arXiv

Improving Stability of Low-Inertia Systems using Virtual Induction Machine Synchronization for Grid-Following Converters

This paper presents a novel strategy for the synchronization of grid-following Voltage Source Converters (VSCs) in power systems with low rotational inertia. The proposed synchronization unit is based on emulating the physical properties of an induction machine and capitalizes on its inherent grid-friendly properties such as self-synchronization, oscillation damping, and standalone capabilities. To this end, the mathematical model of an induction machine is analyzed and reformulated to obtain the unknown grid frequency by processing the voltage and current measurements at the converter output. This eliminates the need for a Phase-Locked Loop (PLL) unit, traditionally employed in grid-following VSC control schemes, while simultaneously preserving the system- and device-level control. Furthermore, we provide the appropriate steps for obtaining an index-1 DAE representation of the induction-machine-based synchronization unit, suitable for stability analysis. Our analysis shows that replacing the PLL unit with the virtual induction machine-based synchronization may considerably improve the stability of systems with grid-following converters and facilitate the frequency containment. Furthermore, we validate the performance of the proposed synchronization unit through simulations and provide recommendations for its tuning.

preprint2022arXiv

Multiple Ancillary Services Provision by Distributed Energy Resources in Active Distribution Networks

The electric power system is currently experiencing radical changes stemming from the increasing share of renewable energy resources and the consequent decommissioning of conventional power plants based on synchronous generators. Since the principal providers of ancillary services are being phased out, new flexibility and reserve providers are needed. The proliferation of Distributed Energy Resources (DERs) in modern distribution networks has opened new possibilities for distribution system operators, enabling them to fill the market gap by harnessing the DER flexibility. This paper introduces a novel centralized MPC-based controller that enables the concurrent provision of voltage support, primary and secondary frequency control by adjusting the setpoints of a heterogeneous group of DERs in active distribution grids. The input-multirate control framework is used to accommodate the distinct timescales and provision requirements of each ancillary service and to ensure that the available resources are properly allocated. Furthermore, an efficient way for incorporating network constraints in the formulation is proposed, where network decomposition is applied to a linear power flow formulation together with network reduction. In addition, different timescale dynamics of the employed DERs and their capability curves are included. The performance of the proposed controller is evaluated on several case studies via dynamic simulations of the IEEE 33-bus system.

preprint2022arXiv

Sparse Structure Design for Stochastic Linear Systems via a Linear Matrix Inequality Approach

In this paper, we propose a sparsity-promoting feedback control design for stochastic linear systems with multiplicative noise. The objective is to identify a sparse control architecture that optimizes the closed-loop performance while stabilizing the system in the mean-square sense. The proposed approach approximates the nonconvex combinatorial optimization problem by minimizing various matrix norms subject to the Linear Matrix Inequality (LMI) stability condition. We present two design problems to reduce the number of actuators via the static state-feedback and a low-dimensional output. A regularized linear quadratic regulator with multiplicative noise (LQRm) optimal control problem and its convex relaxation are presented to demonstrate the tradeoff between the suboptimal closed-loop performance and the sparsity degree of control structure. Case studies on power grids for wide-area frequency control show that the proposed sparsity-promoting control can considerably reduce the number of actuators without significant loss in system performance. The sparse control architecture is robust to substantial system-level disturbances while achieving mean-square stability.

preprint2020arXiv

A Reinforcement Learning Approach for Fast Frequency Control in Low-Inertia Power Systems

The electric grid is undergoing a major transition from fossil fuel-based power generation to renewable energy sources, typically interfaced to the grid via power electronics. The future power systems are thus expected to face increased control complexity and challenges pertaining to frequency stability due to lower levels of inertia and damping. As a result, the frequency control and development of novel ancillary services is becoming imperative. This paper proposes a data-driven control scheme, based on Reinforcement Learning (RL), for grid-forming Voltage Source Converters (VSCs), with the goal of exploiting their fast response capabilities to provide fast frequency control to the system. A centralized RL-based controller collects generator frequencies and adjusts the VSC power output, in response to a disturbance, to prevent frequency threshold violations. The proposed control scheme is analyzed and its performance evaluated through detailed time-domain simulations of the IEEE 14-bus test system.

preprint2020arXiv

MPC-Based Fast Frequency Control of Voltage Source Converters in Low-Inertia Power Systems

A rapid deployment of renewable generation has led to significant reduction in the rotational system inertia and damping, thus making frequency control in power systems more challenging. This paper proposes a novel control scheme based on Model Predictive Control (MPC) for converter-interfaced generators operating in a grid-forming mode, with the goal of exploiting their fast response capabilities to provide fast frequency control service to the system. The controller manipulates converter power injections to limit the frequency nadir and rate-of-change-of-frequency after a disturbance. Both centralized and decentralized MPC approaches are considered and compared in terms of performance and practical implementation. Special attention is given to the decentralized controller by generating an explicit MPC solution to enhance computational efficiency and reduce hardware requirements. Simulation results obtained from a high-fidelity differential-algebraic equation model of the IEEE 39-bus system demonstrate the effectiveness of the proposed control schemes.