Source author record

O. Lundh

O. Lundh appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2022arXiv

European Strategy for Particle Physics -- Accelerator R&D Roadmap

The 2020 update of the European Strategy for Particle Physics emphasised the importance of an intensified and well-coordinated programme of accelerator R&D, supporting the design and delivery of future particle accelerators in a timely, affordable and sustainable way. This report sets out a roadmap for European accelerator R&D for the next five to ten years, covering five topical areas identified in the Strategy update. The R&D objectives include: improvement of the performance and cost-performance of magnet and radio-frequency acceleration systems; investigations of the potential of laser / plasma acceleration and energy-recovery linac techniques; and development of new concepts for muon beams and muon colliders. The goal of the roadmap is to document the collective view of the field on the next steps for the R&D programme, and to provide the evidence base to support subsequent decisions on prioritisation, resourcing and implementation.

preprint2022arXiv

Mechanisms to control laser-plasma coupling in laser wakefield electron acceleration

Experimental results, supported by precise modelling, demonstrate optimisation of a plasma-based injector with intermediate laser pulse energy ($<1$ J), corresponding to a normalised vector potential $a_0 = 2.15$, using ionisation injection in a tailored plasma density profile. An increase in electron bunch quality and energy is achieved experimentally with the extension of the density downramp at the plasma exit. Optimisation of the focal position of the laser pulse in the tailored plasma density profile is shown to efficiently reduce electron bunch angular deviation, leading to a better alignment of the electron bunch with the laser axis. Single peak electron spectra are produced in a previously unexplored regime by combining an early focal position and adaptive optic control of the laser wavefront through optimising the symmetry of the pre-focal laser energy distribution. Experimental results have been validated through particle-in-cell simulations using realistic laser energy, phase distribution, and temporal envelope, allowing for accurate predictions of difficult to model parameters, such as total charge and spatial properties of the electron bunches, opening the way for more accurate modelling for the design of plasma-based accelerators.

preprint2020arXiv

Interaction of ultraintense radially-polarized laser pulses with plasma mirrors

We present experimental results of vacuum laser acceleration (VLA) of electrons using radially polarized laser pulses interacting with a plasma mirror. Tightly focused radially polarized laser pulses have been proposed for electron acceleration because of their strong longitudinal electric field, making them ideal for VLA. However, experimental results have been limited until now because injecting electrons into the laser field has remained a considerable challenge. Here, we demonstrate experimentally that using a plasma mirror as an injector solves this problem and permits to inject electrons at the ideal phase of the laser, resulting in the acceleration of electrons along the laser propagation direction while reducing the electron beam divergence compared to the linear polarization case. We obtain electron bunches with few-MeV energies and a 200 pC charge, thus demonstrating for the first time electron acceleration to relativistic energies using a radially polarized laser. High-harmonic generation from the plasma surface is also measured and provides additional insight into the injection of electrons into the laser field upon its reflection on the plasma mirror. Detailed comparisons between experimental results and full 3D simulations unravel the complex physics of electron injection and acceleration in this new regime: we find that electrons are injected into the radially polarized pulse in the form of two spatially-separated bunches emitted from the p-polarized regions of the focus. Finally, we leverage on the insight brought by this study to propose and validate a more optimal experimental configuration that can lead to extremely peaked electron angular distributions and higher energy beams.

preprint2012arXiv

Betatron emission as a diagnostic for injection and acceleration mechanisms in laser-plasma accelerators

Betatron x-ray emission in laser-plasma accelerators is a promising compact source that may be an alternative to conventional x-ray sources, based on large scale machines. In addition to its potential as a source, precise measurements of betatron emission can reveal crucial information about relativistic laser-plasma interaction. We show that the emission length and the position of the x-ray emission can be obtained by placing an aperture mask close to the source, and by measuring the beam profile of the betatron x-ray radiation far from the aperture mask. The position of the x-ray emission gives information on plasma wave breaking and hence on the laser non-linear propagation. Moreover, the measurement of the longitudinal extension helps one to determine whether the acceleration is limited by pump depletion or dephasing effects. In the case of multiple injections, it is used to retrieve unambiguously the position in the plasma of each injection. This technique is also used to study how, in a capillary discharge, the variations of the delay between the discharge and the laser pulse affect the interaction. The study reveals that, for a delay appropriate for laser guiding, the x-ray emission only occurs in the second half of the capillary: no electrons are injected and accelerated in the first half.

preprint2012arXiv

Laser Wakefield Acceleration Using Wire Produced Double Density Ramps

A novel approach to implement and control electron injection into the accelerating phase of a laser wakefield accelerator (LWFA) is presented. It utilizes a wire, which is introduced into the flow of a supersonic gas jet creating shock waves and three regions of differing plasma electron density. If tailored appropriately, the laser plasma interaction takes place in three stages: Laser self-compression, electron injection and acceleration in the second plasma wave period. Compared to self-injection by wavebreaking of a nonlinear plasma wave in a constant density plasma, this scheme increases beam charge by up to one order of magnitude in the quasi-monoenergetic regime. Electron acceleration in the second plasma wave period reduces electron beam divergence by approximately 25 %, and the localized injection at the density downramps results in spectra with less than a few percent relative spread.

preprint2011arXiv

Mapping the X-Ray Emission Region in a Laser-Plasma Accelerator

The x-ray emission in laser-plasma accelerators can be a powerful tool to understand the physics of relativistic laser-plasma interaction. It is shown here that the mapping of betatron x-ray radiation can be obtained from the x-ray beam profile when an aperture mask is positioned just beyond the end of the emission region. The influence of the plasma density on the position and the longitudinal profile of the x-ray emission is investigated and compared to particle-in-cell simulations. The measurement of the x-ray emission position and length provides insight on the dynamics of the interaction, including the electron self-injection region, possible multiple injection, and the role of the electron beam driven wakefield.

preprint2009arXiv

Laser-driven plasma waves in capillary tubes

The excitation of plasma waves over a length of up to 8 centimeters is, for the first time, demon- strated using laser guiding of intense laser pulses through hydrogen filled glass capillary tubes. The plasma waves are diagnosed by spectral analysis of the transmitted laser radiation. The dependence of the spectral redshift, measured as a function of filling pressure, capillary tube length and incident laser energy, is in excellent agreement with simulation results. The longitudinal accelerating field inferred from the simulations is in the range 1 -10 GV/m.