Source author record

O. A. Shumilkina

O. A. Shumilkina appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2010arXiv

Absolute calibration of photodetectors: photocurrent multiplication versus photocurrent subtraction

We report testing of the new absolute method of photodetectors calibration based on the difference-signal measurement for two-mode squeezed vacuum by comparison with the traditional absolute method based on the coincidence counting. Using low-gain parametric down conversion we have measured the quantum efficiency of a counting detector by both methods. The difference-signal method was adapted for the counting detectors by taking into account the dead-time effect.

preprint2010arXiv

Biphoton compression in standard optical fiber: exact numerical calculation

Generation of two-photon wavepackets, produced by spontaneous parametric down conversion in crystals with linearly chirped quasi-phase matching grating, is analyzed. Although being spectrally broad, two-photon wavepackets produced this way are not Fourier transform limited. In the paper we discuss the temporal compression of the wavepackets, exploiting the insertion of a standard optical fiber in the path of one of the two photons. The effect is analyzed by means of full numerical calculation and the exact dispersion dependencies in both the crystal and the fiber are considered. The study opens the way to the practical realization of this idea.

preprint2010arXiv

Comparative Test of Two Methods of Quantum Efficiency Absolute Measurement Based on Squeezed Vacuum Direct Detection

We realize and test in experiment a method recently proposed for measuring absolute quantum efficiency of analog photodetectors. Similarly to the traditional (Klyshko) method of absolute calibration, the new one is based on the direct detection of two-mode squeezed vacuum at the output of a traveling wave OPA. However, in the new method one measures the difference-photocurrent variance rather than the correlation function of photocurrents (number of coincidences), which makes the technique applicable for high-gain OPA. In this work we test the new method versus the traditional one for the case of photon-counting detectors where both techniques are valid.