Researcher profile

Norbert Weber

Norbert Weber contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Cell voltage model for Li-Bi liquid metal batteries

Lithium-bismuth bimetallic cells are amongst the best explored liquid metal batteries. A simple and fast quasi-one-dimensional cell voltage model for such devices is presented. The equilibrium cell potential is obtained from a complex two-dimensional fit of data drawn from multiple studies of equilibrium cell potential and rendered congruent with the phase diagram. Likewise, several analytical and fit functions for the ohmic potential drop across the electrolyte are provided for different battery geometries. Mass transport overpotentials originating from the alloying of Li into Bi are modelled by solving a diffusion equation, either analytically or numerically, and accounting for the volume change of the positive electrode. The applicability and limitations of the model are finally illustrated in three distinct experimental settings.

preprint2022arXiv

Layer coupling between solutal and thermal convection in liquid metal batteries

For longer than one decade, liquid metal batteries (LMBs) are developed with the primary aim to provide economic stationary energy storage. Featuring two liquid metal electrodes separated by a molten salt electrolyte, LMBs operate at elevated temperature as simple concentration cells. Therefore, efficient mass transfer is a basic prerequisite for their economic operation. Understanding these mechanisms cannot be limited at the single layer level. With this motivation, the effects of solutal- and thermally-driven flow are studied, as well as the flow coupling between the three liquid layers of the cell. It is shown that solutal convection appears first and thermal convection much later. While the presence of solutal flow depends on the mode of operation (charge or discharge), the occurrence of thermal convection is dictated by the geometry (thickness of layers). The coupling of the flow phenomena between the layers is intriguing: while thermal convection is confined to its area of origin, i.e. the electrolyte, solutal convection is able to drive flow in the positive electrode and in the electrolyte.

preprint2022arXiv

Transient behaviour of electrovortex flow in a cylindrical container

This study is a continuation of the combined experimental and numerical investigation [1] of the flow of the eutectic GaInSn alloy inside a cylindrical vessel exposed to a constant electrical current. The emerging electrovortex flow driven by the interaction of the current, which is applied through a tapered electrode, with its own magnetic field might have both detrimental and advantageous effects in liquid metal batteries. While the former work [1] was mainly concerned with time-averaged results, this paper focuses on the transient behaviour of the electrovortex flow which becomes most relevant under the influence of an external axial field. The additional Lorentz force generated by the interaction of the imposed current with the vertical component of the geomagnetic field bz drives the ordinary electrovortex jet flow into a swirling motion. Velocity distributions and motion characteristics, such as spiral streamlines and shortened and irregularly swinging jet regions, are investigated. The mechanism is analysed in detail for bz = 25.5 μT. The maximum angular velocity of the rotating jet is basically linearly dependent on bz, at least for the values studied here. A good agreement between the transient simulation and the experimental result is shown.

preprint2020arXiv

Thermal neutron radiography of a passive proton exchange membrane fuel cell for portable hydrogen energy systems

A proton exchange membrane fuel cell (PEMFC) for low power and portable applications is studied with thermal neutron radiography. The PEMFC operates under full passive conditions, with an air-breathing cathode and a dead-end anode supplied with static ambient air and dry hydrogen, respectively. A columnar cathodic plate favors the mobility of water drops over the cathode surface and their elimination. Thermal neutron images show liquid water build up during operation with the cell in vertical and horizontal positions, i.e. with its main plane aligned parallel and perpendicular to the gravity field, respectively. Polarization curves and impedance spectroscopy show cell orientation dependent response that can be related with the water accumulation profiles. In vertical position, lower water contents in the cathode electrode is favored by the elimination of water drops rolling over the cathode surface and the onset of natural convection. As a consequence, oxygen transport is improved in the vertical cell, that can be operated full passive for hours under ambient conditions, providing steady peak power densities above 100 mW/cm2. Gravity and natural convection are less effective in horizontal position, leading to a 17% decrease in peak power density due to oxygen transport losses. The horizontal position is especially adverse if the upper electrode is the cathode, because of anode flooding causing cell failure after production of a small amount of water (5 mg/cm2). The combined information from thermal neutron radiography and cell response characteristics explains the important influence of cell orientation on the performance of a fully passive air-breathing PEMFC for portable applications.