Source author record

Nobuyasu Shiga

Nobuyasu Shiga appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2020arXiv

Information transfer based on precision time synchronization via wireless interferometry

The growing demand of high-bandwidth and low-latency information transfer in information and communication technologies such as data centres and in-vehicle networks has increased the importance of optical communication networks in recent years. However, complicated arbitration schemes can impose significant overheads in data transfer, which may inhibit the full exploitation of the potential of optical interconnects. Herein, we propose an arbitration protocol based on precision time synchronization via wireless two-way interferometry (Wi-Wi), and numerically validate its efficiency including the ability to impose a strict upper bound on the latency of data transfer. Compared with the conventional carrier sense multiple access/collision detection (CSMA/CD)-based approach, a significant improvement in the data transfer was observed especially in the cases with high traffic flow rate. Furthermore, we conducted a proof-of-principle experiment for Wi-Wi-based data transfer between two electrically connected nodes and confirmed that the skew was less than 300 ns and remained stable over time. Conversely, non-WiWi-based data transfer exhibited huge and unstable skew. These results indicate that precision time synchronization is a promising resource to significantly reduce the communication overheads and ensure low latency for future networks and real-time applications.

preprint2014arXiv

Accelerating the Averaging Rate of Atomic Ensemble Clock Stability using Atomic Phase Lock

We experimentally demonstrated that the stability of an atomic clock improves at fastest rate $τ^{-1}$ (where $τ$ is the averaging time) when the phase of a local oscillator is genuinely compared to the continuous phase of many atoms in a single trap (atomic phase lock). For this demonstration, we developed a simple method that repeatedly monitors the atomic phase while retaining its coherence by observing only a portion of the whole ion cloud. Using this new method, we measured the continuous phase over 3 measurement cycles, and thereby improved the stability scaling from $τ^{-1/2}$ to $τ^{-1}$ during the 3 measurement cycles. %Compared with the standard method that initialize phase during each measurement cycle, the long term stability was improved by a factor of $\sqrt{n_{cp}}$ (where $n_{cp}$ is the number of continuous phase measurements). This simple method provides a path by which atomic clocks can approach a quantum projection noise limit, even when the measurement noise is dominated by the technical noise.

preprint2012arXiv

Locking Local Oscillator Phase to the Atomic Phase via Weak Measurement

We propose a new method to reduce the frequency noise of a Local Oscillator (LO) to the level of white phase noise by maintaining (not destroying by projective measurement) the coherence of the ensemble pseudo-spin of atoms over many measurement cycles. This scheme uses weak measurement to monitor the phase in Ramsey method and repeat the cycle without initialization of phase and we call, "atomic phase lock (APL)" in this paper. APL will achieve white phase noise as long as the noise accumulated during dead time and the decoherence are smaller than the measurement noise. A numerical simulation confirms that with APL, Allan deviation is averaged down at a maximum rate that is proportional to the inverse of total measurement time, tau^-1. In contrast, the current atomic clocks that use projection measurement suppress the noise only down to the level of white frequency, in which case Allan deviation scales as tau^-1/2. Faraday rotation is one of the possible ways to realize weak measurement for APL. We evaluate the strength of Faraday rotation with 171Yb+ ions trapped in a linear rf-trap and discuss the performance of APL. The main source of the decoherence is a spontaneous emission induced by the probe beam for Faraday rotation measurement. One can repeat the Faraday rotation measurement until the decoherence become comparable to the SNR of measurement. We estimate this number of cycles to be ~100 cycles for a realistic experimental parameter.

preprint2009arXiv

Buffer gas induced collision shift for the $^{88}$Sr $\bf{^1S_0-^3P_1}$ clock transition

Precision saturation spectroscopy of the $^{88}{\rm Sr} ^1S_0-^3P_1$ is performed in a vapor cell filled with various rare gas including He, Ne, Ar, and Xe. By continuously calibrating the absolute frequency of the probe laser, buffer gas induced collision shifts of $\sim $kHz are detected with gas pressure of 1-20 mTorr. Helium gave the largest fractional shift of $1.6 \times 10^{-9} {\rm Torr}^{-1}$. Comparing with a simple impact calculation and a Doppler-limited experiment of Holtgrave and Wolf [Phys. Rev. A {\bf 72}, 012711 (2005)], our results show larger broadening and smaller shifting coefficient, indicating effective atomic loss due to velocity changing collisions. The applicability of the result to the $^1S_0-^3P_0$ optical lattice clock transition is also discussed.

preprint2009arXiv

Experimental Uhrig Dynamical Decoupling using Trapped Ions

We present a detailed experimental study of the Uhrig Dynamical Decoupling (UDD) sequence in a variety of noise environments. Our qubit system consists of a crystalline array of $^{9}$Be$^{+}$ ions confined in a Penning trap. We use an electron-spin-flip transition as our qubit manifold and drive qubit rotations using a 124 GHz microwave system. We study the effect of the UDD sequence in mitigating phase errors and compare against the well known CPMG-style multipulse spin echo as a function of pulse number, rotation axis, noise spectrum, and noise strength. Our results agree well with theoretical predictions for qubit decoherence in the presence of classical phase noise, accounting for the effect of finite-duration $π$ pulses. Finally, we demonstrate that the Uhrig sequence is more robust against systematic over/underrotation and detuning errors than is multipulse spin echo, despite the precise prescription for pulse-timing in UDD.