Researcher profile

Nilanjan Ray Chaudhuri

Nilanjan Ray Chaudhuri contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Preventing Outages under Coordinated Cyber-Physical Attack with Secured PMUs

Due to the potentially severe consequences of coordinated cyber-physical attacks (CCPA), the design of defenses has gained significant attention. A popular approach is to eliminate the existence of attacks by either securing existing sensors or deploying secured PMUs. In this work, we improve this approach by lowering the defense target from eliminating attacks to preventing outages and reducing the required number of PMUs. To this end, we formulate the problem of PMU Placement for Outage Prevention (PPOP) under DC power flow model as a tri-level non-linear optimization problem and transform it into a bi-level mixed-integer linear programming (MILP) problem. Then, we propose an alternating optimization framework to solve PPOP by iteratively adding constraints, for which we develop two constraint generation algorithms. In addition, for large-scale grids, we propose a polynomial-time heuristic algorithm to obtain suboptimal solutions. Next, we extend our solution to achieve the defense goal under AC power flow model. Finally, we evaluate our algorithm on IEEE 30-bus, 57-bus, 118-bus, and 300-bus systems, which demonstrates the potential of the proposed approach in greatly reducing the required number of PMUs.

preprint2021arXiv

On Stability Analysis of Power Grids with Synchronous Generators and Grid-Forming Converters under DC-side Current Limitation

Stability of power grids with synchronous generators (SGs) and renewable generation interfaced with grid-forming converters (GFCs) under dc-side current limitation is studied. To that end, we first consider a simple 2-bus test system and reduced-order models to highlight the fundamental difference between two classes of GFC controls -- (A) droop, dispatchable virtual oscillator control (dVOC) and virtual synchronous machine (VSM), and (B) matching control. Next, we study Lyapunov stability and input-output stability of the dc voltage dynamics of class-A GFCs for the simple system and extend it to a generic system. Next, we provide a sufficiency condition for input-to-state stability of the 2-bus system with a class-B GFC and extend it for a generic system. Finally, time-domain simulations from a reduced-order averaged model of the simple test system and a detailed switched model of the GFC validate the proposed conditions.

preprint2021arXiv

Power Grid State Estimation under General Cyber-Physical Attacks

Effective defense against cyber-physical attacks in power grid requires the capability of accurate damage assessment within the attacked area. While some solutions have been proposed to recover the phase angles and the link status (i.e., breaker status) within the attacked area, existing solutions made the limiting assumption that the grid stays connected after the attack. To fill this gap, we study the problem of recovering the phase angles and the link status under a general cyber-physical attack that may partition the grid into islands. To this end, we (i) show that the existing solutions and recovery conditions still hold if the post-attack power injections in the attacked area are known, and (ii) propose a linear programming-based algorithm that can perfectly recover the link status under certain conditions even if the post-attack power injections are unknown. Our numerical evaluations based on the Polish power grid demonstrate that the proposed algorithm is highly accurate in localizing failed links once the phase angles are known.

preprint2021arXiv

Verifiable Failure Localization in Smart Grid under Cyber-Physical Attacks

Cyber-physical attacks impose a significant threat to the smart grid, as the cyber attack makes it difficult to identify the actual damage caused by the physical attack. To defend against such attacks, various inference-based solutions have been proposed to estimate the states of grid elements (e.g., transmission lines) from measurements outside the attacked area, out of which a few have provided theoretical conditions for guaranteed accuracy. However, these conditions are usually based on the ground truth states and thus not verifiable in practice. To solve this problem, we develop (i) verifiable conditions that can be tested based on only observable information, and (ii) efficient algorithms for verifying the states of links (i.e., transmission lines) within the attacked area based on these conditions. Our numerical evaluations based on the Polish power grid and IEEE 300-bus system demonstrate that the proposed algorithms are highly successful in verifying the states of truly failed links, and can thus greatly help in prioritizing repairs during the recovery process.