Researcher profile

Nicolas Delerue

Nicolas Delerue contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
10works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2016arXiv

Comparison of Coherent Smith-Purcell radiation and Coherent Transition Radiation

Smith-Purcell radiation and Transition Radiation are two radiative phenomenon that occur in charged particles accelerators. For both the emission can be significantly enhanced with sufficiently short pulses and both can be used to measure the form factor of the pulse. We compare the yield of these phenomenon in different configurations and look at their application as bunch length monitors, including background filtering and rejection. We apply these calculations to the specific case of the CLIO Free Electron laser.

preprint2015arXiv

Study of Phase Reconstruction Techniques applied to Smith-Purcell Radiation Measurements

Measurements of coherent radiation at accelerators typically give the absolute value of the beam profile Fourier transform but not its phase. Phase reconstruction techniques such as Hilbert transform or Kramers Kronig reconstruction are used to recover such phase. We report a study of the performances of these methods and how to optimize the reconstructed profiles.

preprint2014arXiv

On the suitability of longitudinal profile measurements using Coherent Smith-Purcell radiation for high current proton beams

The use of Smith-Purcell radiation to measure electrons longitudinal profiles has been demonstrated at several facilities in the picosecond and sub-picosecond range. There is a strong interest for the development of non intercepting longitudinal profile diagnostics for high current proton beams. We present here results of simulations on the expected yield of longitudinal profile monitors using Smith-Purcell radiation for such proton beams.

preprint2014arXiv

Resolution of Longitudinal Profile Measures using Coherent Smith-Purcell Radiation with the Number of Gratings and the Number of Pulses Used

The E-203 collaboration is testing a device on FACET at SLAC to measure the longitudinal profile of electron bunches using Smith-Purcell radiation. At FACET the electron bunches have an energy of 20~GeV and a duration of a few hundred femtoseconds. Smith-Purcell radiation is emitted when a charged particle passes close to the surface of a metallic grating. We have studied the stability of the measurement from pulse to pulse and the resolution of the measure depending on the number of gratings used.

preprint2014arXiv

Study of Phase Reconstruction Techniques applied to Smith-Purcell Radiation Measurements

Measurements of coherent radiation at accelerators typically give the absolute value of the beam profile Fourier transform but not its phase. Phase reconstruction techniques such as Hilbert transform or Kramers Kronig reconstruction are used to recover such phase. We report a study of the performances of these methods and how to optimize the reconstructed profiles.

preprint2011arXiv

High flux polarized gamma rays production: first measurements with a four-mirror cavity at the ATF

The next generation of e+/e- colliders will require a very intense flux of gamma rays to allow high current polarized positrons to be produced. This can be achieved by converting polarized high energy photons in polarized pairs into a target. In that context, an optical system consisting of a laser and a four-mirror passive Fabry-Perot cavity has recently been installed at the Accelerator Test Facility (ATF) at KEK to produce a high flux of polarized gamma rays by inverse Compton scattering. In this contribution, we describe the experimental system and present preliminary results. An ultra-stable four-mirror non planar geometry has been implemented to ensure the polarization of the gamma rays produced. A fiber amplifier is used to inject about 10W in the high finesse cavity with a gain of 1000. A digital feedback system is used to keep the cavity at the length required for the optimal power enhancement. Preliminary measurements show that a flux of about $4\times10^6 γ$/s with an average energy of about 24 MeV was generated. Several upgrades currently in progress are also described.

preprint2011arXiv

Single Shot Transverse Emittance Measurement of multi-MeV Electron Beams Using a Long Pepper-Pot

We present a pepper-pot design in which we address the problem of penetration by high energy particle, deriving analytical expressions and performing GEANT4 simulations for the estimation of the error introduced by a long (thick) pepper-pot. We also show that a careful design allows to measure the emittance of electron beam of several hundred MeV and beyond.

preprint2010arXiv

Numerical Analysis of Space Charge Effects in Electron Bunches at Laser-Driven Plasma Accelerators

Laser-driven Plasma Accelerators (LPA) have successfully generated high energy, high charge electron bunches which can reach many kA peak current, over short distances. Space charge issues, even in transport lines as simple as a drift section, have to be carefully taken into account since they can degrade the beam quality, preventing any further application of such electron beams. We analyse the space charge effects within an electron bunch with numerical simulations in order to assess their effect on the beam. We use LPA beam parameters published in previous experimental studies. These studies can give an indication of the working point where space charge can dominate the beam dynamics and has to be taken into account in the application of such beams.

preprint2010arXiv

Single shot emittance measurement using Optical Transition Radiation

We describe a method that uses Optical Transition Radiation (OTR) screens to measure in a single shot the emittance of an electron beam with an energy greater than 100 MeV. Our setup consists of 4 OTR screens located near a beam waist. A fit of the 4 profiles allows the reconstruction of the Twiss parameters and hence a calculation of the beam emittance. This layout has been simulated using Mathematica to study its sensitivity to errors and using Geant4 to include effects due to the scattering of the electrons in the screens. Some assumptions made in this document are conservative to allow for unexpected experimental issues.