Researcher profile

Nicola Marchili

Nicola Marchili contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2023arXiv

General relativistic effects and the near-infrared and X-ray variability of Sgr A* I

The near-infrared (NIR) and X-ray emission of Sagittarius A* shows occasional bright flares that are assumed to originate from the innermost region of the accretion flow. We identified $25$ $4.5 μm$ and $24$ X-ray flares in archival data obtained with the \textit{Spitzer} and \textit{Chandra} observatories. With the help of general relativistic ray-tracing code, we modeled trajectories of ``hot spots&#39;&#39; and studied the light curves of the flares for signs of the effects of general relativity. Despite their apparent diversity in shape, all flares share a common, exponential impulse response, a characteristic shape that is the building block of the variability. This shape is symmetric, that is, the rise and fall times are the same. Furthermore, the impulse responses in the NIR and X-ray are identical within uncertainties, with an exponential time constant $τ\sim 15$ minute. The observed characteristic flare shape is inconsistent with hot-spot orbits viewed edge-on. Individually modeling the light curves of the flares, we derived constraints on the inclination of the orbital plane of the hot spots with respect to the observer ($i \sim 30^{\circ} , < 75^{\circ} $) and on the characteristic timescale of the intrinsic variability (tens of minutes).

preprint2022arXiv

Millimeter light curves of Sagittarius A* observed during the 2017 Event Horizon Telescope campaign

The Event Horizon Telescope (EHT) observed the compact radio source, Sagittarius A* (Sgr A*), in the Galactic Center on 2017 April 5-11 in the 1.3 millimeter wavelength band. At the same time, interferometric array data from the Atacama Large Millimeter/submillimeter Array and the Submillimeter Array were collected, providing Sgr A* light curves simultaneous with the EHT observations. These data sets, complementing the EHT very-long-baseline interferometry, are characterized by a cadence and signal-to-noise ratio previously unattainable for Sgr A* at millimeter wavelengths, and they allow for the investigation of source variability on timescales as short as a minute. While most of the light curves correspond to a low variability state of Sgr A*, the April 11 observations follow an X-ray flare, and exhibit strongly enhanced variability. All of the light curves are consistent with a red noise process, with a power spectral density (PSD) slope measured to be between -2 and -3 on timescales between 1 min and several hours. Our results indicate a steepening of the PSD slope for timescales shorter than 0.3 h. The spectral energy distribution is flat at 220 GHz and there are no time-lags between the 213 and 229 GHz frequency bands, suggesting low optical depth for the event horizon scale source. We characterize Sgr A*&#39;s variability, highlighting the different behavior observed just after the X-ray flare, and use Gaussian process modeling to extract a decorrelation timescale and a PSD slope. We also investigate the systematic calibration uncertainties by analyzing data from independent data reduction pipelines.

preprint2014arXiv

Herschel SPIRE Fourier Transform Spectrometer: Calibration of its Bright-source Mode

The Fourier Transform Spectrometer (FTS) of the Spectral and Photometric Imaging REceiver (SPIRE) on board the ESA Herschel Space Observatory has two detector setting modes: (a) a nominal mode, which is optimized for observing moderately bright to faint astronomical targets, and (b) a bright-source mode recommended for sources significantly brighter than 500 Jy, within the SPIRE FTS bandwidth of 446.7-1544 GHz (or 194-671 microns in wavelength), which employs a reduced detector responsivity and out-of-phase analog signal amplifier/demodulator. We address in detail the calibration issues unique to the bright-source mode, describe the integration of the bright-mode data processing into the existing pipeline for the nominal mode, and show that the flux calibration accuracy of the bright-source mode is generally within 2% of that of the nominal mode, and that the bright-source mode is 3 to 4 times less sensitive than the nominal mode.

preprint2014arXiv

Herschel SPIRE FTS telescope model correction

Emission from the Herschel telescope is the dominant source of radiation for the majority of SPIRE Fourier transform spectrometer (FTS) observations, despite the exceptionally low emissivity of the primary and secondary mirrors. Accurate modelling and removal of the telescope contribution is, therefore, an important and challenging aspect of FTS calibration and data reduction pipeline. A dust-contaminated telescope model with time invariant mirror emissivity was adopted before the Herschel launch. However, measured FTS spectra show a clear evolution of the telescope contribution over the mission and strong need for a correction to the standard telescope model in order to reduce residual background (of up to 7 Jy) in the final data products. Systematic changes in observations of dark sky, taken over the course of the mission, provide a measure of the evolution between observed telescope emission and the telescope model. These dark sky observations have been used to derive a time dependent correction to the telescope emissivity that reduces the systematic error in the continuum of the final FTS spectra to ~0.35 Jy.

preprint2014arXiv

Relative pointing offset analysis of calibration targets with repeated observations with Herschel-SPIRE Fourier-Transform Spectrometer

We present a method to derive the relative pointing offsets for SPIRE Fourier-Transform Spectrometer (FTS) solar system object (SSO) calibration targets, which were observed regularly throughout the Herschel mission. We construct ratios of the spectra for all observations of a given source with respect to a reference. The reference observation is selected iteratively to be the one with the highest observed continuum. Assuming that any pointing offset leads to an overall shift of the continuum level, then these ratios represent the relative flux loss due to mispointing. The mispointing effects are more pronounced for a smaller beam, so we consider only the FTS short wavelength array (SSW, 958-1546 GHz) to derive a pointing correction. We obtain the relative pointing offset by comparing the ratio to a grid of expected losses for a model source at different distances from the centre of the beam, under the assumption that the SSW FTS beam can be well approximated by a Gaussian. In order to avoid dependency on the point source flux conversion, which uses a particular observation of Uranus, we use extended source flux calibrated spectra to construct the ratios for the SSOs. In order to account for continuum variability, due to the changing distance from the Herschel telescope, the SSO ratios are normalised by the expected model ratios for the corresponding observing epoch. We confirm the accuracy of the derived pointing offset by comparing the results with a number of control observations, where the actual pointing of Herschel is known with good precision. Using the method we derived pointing offsets for repeated observations of Uranus (including observations centred on off-axis detectors), Neptune, Ceres and NGC7027. The results are used to validate and improve the point-source flux calibration of the FTS.