Source author record

Neng Fan

Neng Fan appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2020arXiv

Integer Linear Programming Formulations for Double Roman Domination Problem

For a graph $G= (V,E)$, a double Roman dominating function (DRDF) is a function $f : V \to \{0,1,2,3\}$ having the property that if $f (v) = 0$, then vertex $v$ must have at least two neighbors assigned $2$ under $f$ or {at least} one neighbor $u$ with $f (u) = 3$, and if $f (v) = 1$, then vertex $v$ must have at least one neighbor $u$ with $f (u) \ge 2$. In this paper, we consider the double Roman domination problem, which is an optimization problem of finding the DRDF $f$ such that $\sum_{v\in V} f (v)$ is minimum. We propose {five integer linear programming (ILP) formulations and one mixed integer linear programming formulation with polynomial number of constraints for this problem. Some additional valid inequalities and bounds are also proposed for some of these formulations.} Further, we prove that {the first four models indeed solve the double Roman domination problem, and the last two models} are equivalent to the others regardless of the variable relaxation or usage of a smaller number of constraints and variables. Additionally, we use one ILP formulation to give an $H(2(Δ+1))$-approximation algorithm. All proposed formulations and approximation algorithm are evaluated on randomly generated graphs to compare the performance.

preprint2016arXiv

Contingency-Constrained Unit Commitment With Intervening Time for System Adjustments

The N-1-1 contingency criterion considers the con- secutive loss of two components in a power system, with intervening time for system adjustments. In this paper, we consider the problem of optimizing generation unit commitment (UC) while ensuring N-1-1 security. Due to the coupling of time periods associated with consecutive component losses, the resulting problem is a very large-scale mixed-integer linear optimization model. For efficient solution, we introduce a novel branch-and-cut algorithm using a temporally decomposed bilevel separation oracle. The model and algorithm are assessed using multiple IEEE test systems, and a comprehensive analysis is performed to compare system performances across different contingency criteria. Computational results demonstrate the value of considering intervening time for system adjustments in terms of total cost and system robustness.

preprint2014arXiv

Contingency-Constrained Unit Commitment with Post-Contingency Corrective Recourse

We consider the problem of minimizing costs in the generation unit commitment problem, a cornerstone in electric power system operations, while enforcing an N-k-e reliability criterion. This reliability criterion is a generalization of the well-known $N$-$k$ criterion, and dictates that at least $(1-e_ j)$ fraction of the total system demand must be met following the failures of $k$ or fewer system components. We refer to this problem as the Contingency-Constrained Unit Commitment problem, or CCUC. We present a mixed-integer programming formulation of the CCUC that accounts for both transmission and generation element failures. We propose novel cutting plane algorithms that avoid the need to explicitly consider an exponential number of contingencies. Computational studies are performed on several IEEE test systems and a simplified model of the Western US interconnection network, which demonstrate the effectiveness of our proposed methods relative to current state-of-the-art.

preprint2013arXiv

Contingency-Risk Informed Power System Design

We consider the problem of designing (or augmenting) an electric power system at a minimum cost such that it satisfies the N-k-e survivability criterion. This survivability criterion is a generalization of the well-known N-k criterion, and it requires that at least (1- e_j) fraction of the total demand to be met after failures of up to j components, for j=1,...,k. The network design problem adds another level of complexity to the notoriously hard contingency analysis problem, since the contingency analysis is only one of the requirements for the design optimization problem. We present a mixed-integer programming formulation of this problem that takes into account both transmission and generation expansion. We propose an algorithm that can avoid combinatorial explosion in the number of contingencies, by seeking vulnerabilities in intermediary solutions and constraining the design space accordingly. Our approach is built on our ability to identify such system vulnerabilities quickly. Our empirical studies on modified instances from the IEEE 30-bus and IEEE 57-bus systems show the effectiveness of our methods. We were able to solve the transmission and generation expansion problems for k=4 under 2 minutes, while other approaches failed to provide a solution at the end of 2 hours.

preprint2012arXiv

N-k-e Survivable Power System Design

We consider the problem of designing (or augmenting) an electric power system such that it satisfies the N-k-e survivability criterion while minimizing total cost. The survivability criterion requires that at least (1-e) fraction of the total demand can still be met even if any k (or fewer) of the system components fail. We formulate this problem, taking into account both transmission and generation expansion planning, as a mixed-integer program. Two algorithms are designed and tested on modified instances from the IEEE-30-Bus and IEEE- 57-Bus systems.