Source author record

Nagomi Uchida

Nagomi Uchida appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2026arXiv

Evidence for 1.01 s Pulsations of the Central Compact Object in the Supernova Remnant RCW 103 with ASCA, XMM-Newton, and NuSTAR

The neutron-star X-ray source 1E 161348-5055, associated with the supernova remnant RCW 103, exhibits clear intensity variations with a period of 6.67 hr. To clarify the nature of this object and its long periodicity, detailed timing studies were applied to its archival X-ray data, taken with ASCA (in 1993), XMM-Newton (in 2001, 2005, and 2016), and NuSTAR (2016 and 2017). It was assumed that the 6.67 hr period arises due to the beat between the rotation and free precession periods of the star that is slightly aspherical. By removing timing perturbations to be caused by this long periodicity, the six data sets consistently yielded evidence for pulsations at periods of P~1.01 s, to be interpreted as the objects' spin period, although the optimum energy range differed among the data sets. The measured six periods accurately line up on a linear spin-down trend of dP/dt = 1.097x 10^{-12} s/s. The object is implied to have a characteristic age of 14.7 kyr, a spin-down luminosity of 4.2x10^{34} erg/s, which is insufficient to power the X-ray luminosity, a dipole magnetic field of ~4.6x10^{13} G, and a toroidal field of ~7 x10^{15} G. Its similarity and dissimilarity to magnetars are discussed. An emission geometry, which crudely explain these results, is presented.

preprint2022arXiv

Performance of the X-Calibur Hard X-Ray Polarimetry Mission during its 2018/19 Long-Duration Balloon Flight

X-Calibur is a balloon-borne telescope that measures the polarization of high-energy X-rays in the 15--50keV energy range. The instrument makes use of the fact that X-rays scatter preferentially perpendicular to the polarization direction. A beryllium scattering element surrounded by pixellated CZT detectors is located at the focal point of the InFOCμS hard X-ray mirror. The instrument was launched for a long-duration balloon (LDB) flight from McMurdo (Antarctica) on December 29, 2018, and obtained the first constraints of the hard X-ray polarization of an accretion-powered pulsar. Here, we describe the characterization and calibration of the instrument on the ground and its performance during the flight, as well as simulations of particle backgrounds and a comparison to measured rates. The pointing system and polarimeter achieved the excellent projected performance. The energy detection threshold for the anticoincidence system was found to be higher than expected and it exhibited unanticipated dead time. Both issues will be remedied for future flights. Overall, the mission performance was nominal, and results will inform the design of the follow-up mission XL-Calibur, which is scheduled to be launched in summer 2022.

preprint2021arXiv

The simulation framework of the timing-based localization for future all-sky gamma-ray observations with a fleet of Cubesats

The timing-based localization, which utilize the triangulation principle with the different arrival time of gamma-ray photons, with a fleet of Cubesats is a unique and powerful solution for the future all-sky gamma-ray observation, which is a key for identification of the electromagnetic counterpart of the gravitational wave sources. The Cubesats Applied for MEasuring and Localising Transients (CAMELOT) mission is now being promoted by the Hungarian and Japanese collaboration with a basic concept of the nine Cubesats constellations in low earth orbit. The simulation framework for estimation of the localization capability has been developed including orbital parameters, an algorithm to estimate the expected observed profile of gamma-ray photons, finding the peak of the cross-correlation function, and a statistical method to find a best-fit position and its uncertainty. It is revealed that a degree-scale localization uncertainty can be achieved by the CAMELOT mission concept for bright short gamma-ray bursts, which could be covered by future large field of view ground-based telescopes. The new approach utilizing machine-learning approach is also investigated to make the procedure automated for the future large scale constellations. The trained neural network with 10$^6$ simulated light curves generated by the artificial short burst templates successfully predicts the time-delay of the real light curve and achieves a comparable performance to the cross-correlation algorithm with full automated procedures.

preprint2016arXiv

Study of the Polarimetric Performance of a Si/CdTe Semiconductor Compton Camera for the Hitomi Satellite

Gamma-ray polarization offers a unique probes into the geometry of the gamma-ray emission process in celestial objects. The Soft Gamma-ray Detector (SGD) onboard the X-ray observatory Hitomi is a Si/CdTe Compton camera and is expected to be an excellent polarimeter, as well as a highly sensitive spectrometer due to its good angular coverage and resolution for Compton scattering. A beam test of the final-prototype for the SGD Compton camera was conducted to demonstrate its polarimetric capability and to verify and calibrate the Monte Carlo simulation of the instrument. The modulation factor of the SGD prototype camera, evaluated for the inner and outer parts of the CdTe sensors as absorbers, was measured to be 0.649--0.701 (inner part) and 0.637--0.653 (outer part) at 122.2 keV and 0.610--0.651 (inner part) and 0.564--0.592 (outer part) at 194.5 keV at varying polarization angles with respect to the detector. This indicates that the relative systematic uncertainty of the modulation factor is as small as ~3%.