Source author record

N. Webb

N. Webb appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

22works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

22 published item(s)

preprint2025arXiv

Harnessing the XMM-Newton data: X-ray spectral modelling of 4XMM-DR11 detections and 4XMM-DR11s sources

The XMM-Newton X-ray observatory has played a prominent role in astrophysics, conducting precise and thorough observations of the X-ray sky for the past two decades. The most recent iteration of the 4XMM catalogue and one of its latest data releases DR11 mark significant improvements over previous XMM-Newton catalogues, serving as a cornerstone for comprehending the diverse inhabitants of the X-ray sky. We employ detections and spectra extracted from the 4XMM-DR11 catalogue, subjecting them to fitting procedures using simple models. Our study operates within the framework of the XMM2ATHENA project, which focuses on developing state-of-the-art methods that exploit existing XMM-Newton data. We introduce and publicly release four catalogues containing measurements derived from X-ray spectral modelling of sources. The first catalogue encompasses outcomes obtained by fitting an absorbed power law model to all the extracted spectra for individual detections within the 4XMM-DR11 dataset. The second catalogue presents results obtained by fitting both an absorbed power law and an absorbed blackbody model to all unique physical sources listed in the 4XMM-DR11s catalogue, which documents source detection results from overlapping XMM-Newton observations. For the third catalogue we use the five band count rates derived from the pipe line detection of X-ray sources to mimic low resolution spectra to get a rough estimate of the spectral shape (absorbed power-law) of all 4XMM-DR11 detections. In the fourth catalogue, we conduct spectral analyses for the subset of identified sources with extracted spectra, employing various models based on their classification into categories such as AGN, stars, X-ray binaries, and cataclysmic variables. The scientific potential of these catalogues is highlighted by discussing the capabilities of optical and mid-infrared colours for selecting absorbed AGN. (abridged)

preprint2020arXiv

The Unusual Broadband X-ray Spectral Variability of NGC 1313 X-1 seen with XMM$-$Newton, Chandra and NuSTAR

We present results from the major coordinated X-ray observing program on the ULX NGC 1313 X-1 performed in 2017, combining $XMM$-$Newton$, $Chandra$ and $NuSTAR$, focusing on the evolution of the broadband ($\sim$0.3-30.0 keV) continuum emission. Clear and unusual spectral variability is observed, but this is markedly suppressed above $\sim$10-15 keV, qualitatively similar to the ULX Holmberg IX X-1. We model the multi-epoch data with two-component accretion disc models designed to approximate super-Eddington accretion, allowing for both a black hole and a neutron star accretor. With regards to the hotter disc component, the data trace out two distinct tracks in the luminosity-temperature plane, with larger emitting radii and lower temperatures seen at higher observed fluxes. Despite this apparent anti-correlation, each of these tracks individually shows a positive luminosity-temperature relation. Both are broadly consistent with $L\propto{T}^{4}$, as expected for blackbody emission with a constant area, and also with $L\propto{T}^{2}$, as may be expected for an advection-dominated disc around a black hole. We consider a variety of possibilities for this unusual behaviour. Scenarios in which the innermost flow is suddenly blocked from view by outer regions of the super-Eddington disc/wind can explain the luminosity-temperature behaviour, but are difficult to reconcile with the lack of strong variability at higher energies, assuming this emission arises from the most compact regions. Instead, we may be seeing evidence for further radial stratification of the accretion flow than is included in the simple models considered, with a combination of winds and advection resulting in the suppressed high-energy variability.

preprint2016arXiv

A 78 Day X-ray Period Detected from NGC 5907 ULX1 by Swift

We report the detection of a $78.1\pm0.5$ day period in the X-ray lightcurve of the extreme ultraluminous X-ray source NGC 5907 ULX1 ($L_{\rm{X,peak}}\sim5\times10^{40}$ erg s$^{-1}$), discovered during an extensive monitoring program with Swift. These periodic variations are strong, with the observed flux changing by a factor of $\sim$3-4 between the peaks and the troughs of the cycle; our simulations suggest that the observed periodicity is detected comfortably in excess of 3$σ$ significance. We discuss possible origins for this X-ray period, but conclude that at the current time we cannot robustly distinguish between orbital and super-orbital variations.

preprint2016arXiv

Discovery of coherent pulsations from the Ultraluminous X-ray Source NGC 7793 P13

We report the detection of coherent pulsations from the ultraluminous X-ray source NGC 7793 P13. The ~0.42s nearly sinusoidal pulsations were initially discovered in broadband X-ray observations using XMM-Newton and NuSTAR taken in 2016. We subsequently also found pulsations in archival XMM-Newton data taken in 2013 and 2014. The significant (>>5 sigma) detection of coherent pulsations demonstrates that the compact object in P13 is a neutron star with an observed peak luminosity of ~1e40 erg/s (assuming isotropy), well above the Eddington limit for a 1.4 M_sun accretor. This makes P13 the second ultraluminous X-ray source known to be powered by an accreting neutron star. The pulse period varies between epochs, with a slow but persistent spin up over the 2013-2016 period. This spin-up indicates a magnetic field of B ~ 1.5e12 G, typical of many accreting pulsars. The most likely explanation for the extreme luminosity is a high degree of beaming, however this is difficult to reconcile with the sinusoidal pulse profile.

preprint2016arXiv

The Deep and Transient Universe in the SVOM Era: New Challenges and Opportunities - Scientific prospects of the SVOM mission

To take advantage of the astrophysical potential of Gamma-Ray Bursts (GRBs), Chinese and French astrophysicists have engaged the SVOM mission (Space-based multi-band astronomical Variable Objects Monitor). Major advances in GRB studies resulting from the synergy between space and ground observations, the SVOM mission implements space and ground instrumentation. The scientific objectives of the mission put a special emphasis on two categories of GRBs: very distant GRBs at z$>$5 which constitute exceptional cosmological probes, and faint/soft nearby GRBs which allow probing the nature of the progenitors and the physics at work in the explosion. These goals have a major impact on the design of the mission: the on-board hard X-ray imager is sensitive down to 4 keV and computes on line image and rate triggers, and the follow-up telescopes on the ground are sensitive in the NIR. At the beginning of the next decade, SVOM will be the main provider of GRB positions and spectral parameters on very short time scale. The SVOM instruments will operate simultaneously with a wide range of powerful astronomical devices. This rare instrumental conjunction, combined with the relevance of the scientific topics connected with GRB studies, warrants a remarkable scientific return for SVOM. In addition, the SVOM instrumentation, primarily designed for GRB studies, composes a unique multi-wavelength observatory with rapid slew capability that will find multiple applications for the whole astronomy community beyond the specific objectives linked to GRBs. This report lists the scientific themes that will benefit from observations made with SVOM, whether they are specific GRB topics, or more generally all the issues that can take advantage of the multi-wavelength capabilities of SVOM.

preprint2014arXiv

NuSTAR and XMM-Newton observations of the extreme ultraluminous X-ray source NGC 5907 ULX1: A Vanishing Act

We present results obtained from two broadband X-ray observations of the extreme ultraluminous X-ray source (ULX) NGC5907 ULX1, known to have a peak X-ray luminosity of ~5e40 erg/s. These XMM-Newton and NuSTAR observations, separated by only ~4 days, revealed an extreme level of short-term flux variability. In the first epoch, NGC5907 ULX1 was undetected by NuSTAR, and only weakly detected (if at all) with XMM-Newton, while in the second NGC5907 ULX1 was clearly detected at high luminosity by both missions. This implies an increase in flux of ~2 orders of magnitude or more during this ~4 day window. We argue that this is likely due to a rapid rise in the mass accretion rate, rather than to a transition from an extremely obscured to an unobscured state. During the second epoch we observed the broadband 0.3-20.0 keV X-ray luminosity to be (1.55+/-0.06)e40 erg/s, similar to the majority of the archival X-ray observations. The broadband X-ray spectrum obtained from the second epoch is inconsistent with the low/hard accretion state observed in Galactic black hole binaries, but is well modeled with a simple accretion disk model incorporating the effects of photon advection. This strongly suggests that, when bright, NGC5907 ULX1 is a high-Eddington accretor.

preprint2014arXiv

The Large Observatory For x-ray Timing

The Large Observatory For x-ray Timing (LOFT) was studied within ESA M3 Cosmic Vision framework and participated in the final down-selection for a launch slot in 2022-2024. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument, LOFT will study the behaviour of matter under extreme conditions, such as the strong gravitational field in the innermost regions of accretion flows close to black holes and neutron stars, and the supra-nuclear densities in the interior of neutron stars. The science payload is based on a Large Area Detector (LAD, 10 m 2 effective area, 2-30 keV, 240 eV spectral resolution, 1 deg collimated field of view) and a WideField Monitor (WFM, 2-50 keV, 4 steradian field of view, 1 arcmin source location accuracy, 300 eV spectral resolution). The WFM is equipped with an on-board system for bright events (e.g. GRB) localization. The trigger time and position of these events are broadcast to the ground within 30 s from discovery. In this paper we present the status of the mission at the end of its Phase A study.

preprint2014arXiv

The Microchannel X-ray Telescope for the Gamma-Ray Burst mission SVOM

We present the Microchannel X-ray Telescope, a new light and compact focussing telescope that will be flying on the Sino-French SVOM mission dedicated to Gamma-Ray Burst science. The MXT design is based on the coupling of square pore micro-channel plates with a low noise pnCCD. MXT will provide an effective area of about 50 cmsq, and its point spread function is expected to be better than 3.7 arc min (FWHM) on axis. The estimated sensitivity is adequate to detect all the afterglows of the SVOM GRBs, and to localize them to better then 60 arc sec after five minutes of observation.

preprint2013arXiv

Six millisecond pulsars detected by the Fermi Large Area Telescope and the radio/gamma-ray connection of millisecond pulsars

We report on the discovery of gamma-ray pulsations from five millisecond pulsars (MSPs) using the Fermi Large Area Telescope (LAT) and timing ephemerides provided by various radio observatories. We also present confirmation of the gamma-ray pulsations from a sixth source, PSR J2051-0827. Five of these six MSPs are in binary systems: PSRs J1713+0747, J1741+1351, J1600-3053 and the two black widow binary pulsars PSRs J0610-2100 and 2051-0827. The only isolated MSP is the nearby PSR J1024-0719, which is also known to emit X-rays. We present X-ray observations in the direction of PSRs J1600-3053 and J2051-0827. While the latter is firmly detected, we an only give upper limits for the X-ray flux of the former. There are no dedicated X-ray observations available for the other 3 objects. The MSPs mentioned above, together with most of the MSPs detected by Fermi, are used to put together a sample of 30 gamma-ray MSPs which is used to study the morphology and phase connection of radio and gamma-ray pulse profiles. We show that MSPs with pulsed gamma-ray emission which is phase aligned with the radio emission present the steepest radio spectra and the largest magnetic fields at the light cylinder among all MSPs. As well, we also observe a trend towards very low, or undetectable, radio linear polarisation levels. These properties could be attributed to caustic radio emission produced at a range of different altitudes in the magnetosphere. We note that most of these characteristics are also observed in the Crab pulsar, the only other radio pulsar known to exhibit phase-aligned radio and gamma-ray emission.

preprint2013arXiv

The XMM-Newton SSC survey of the Galactic Plane

Many different classes of X-ray sources contribute to the Galactic landscape at high energies. Although the nature of the most luminous X-ray emitters is now fairly well understood, the population of low-to-medium X-ray luminosity (Lx = 10^27-10^34 erg/s) sources remains much less studied, our knowledge being mostly based on the observation of local members. The advent of wide field and high sensitivity X-ray telescopes such as XMM-Newton now offers the opportunity to observe this low-to-medium Lx population at large distances. We report on the results of a Galactic plane survey conducted by the XMM-Newton Survey Science Centre (SSC). Beyond its astrophysical goals, this survey aims at gathering a representative sample of identified X-ray sources at low latitude that can be used later on to statistically identify the rest of the serendipitous sources discovered in the Milky Way. The survey is based on 26 XMM-Newton observations, obtained at |b| < 20 deg, distributed over a large range in Galactic longitudes and covering a summed area of 4 deg2. The flux limit of our survey is 2 x 10-15 erg/cm^2/s in the soft (0.5 - 2 keV) band and 1 x 10^-14 erg/cm^2/s in the hard (2 - 12 keV) band. We detect a total of 1319 individual X-ray sources. Using optical follow-up observations supplemented by cross-correlation with a large range of multi-wavelength archival catalogues we identify 316 X-ray sources. This constitutes the largest group of spectroscopically identified low latitude X-ray sources at this flux level. The majority of the identified X-ray sources are active coronae with spectral types in the range A - M at maximum distances of ~ 1 kpc. The number of identified active stars increases towards late spectral types, reaching a maximum at K. (abridged)

preprint2012arXiv

A Young Massive Stellar Population Around the Intermediate Mass Black Hole ESO 243-49 HLX-1

We present Hubble Space Telescope and simultaneous Swift X-ray telescope observations of the strongest candidate intermediate mass black hole ESO 243-49 HLX-1. Fitting the spectral energy distribution from X-ray to near-infrared wavelengths showed that the broadband spectrum is not consistent with simple and irradiated disc models, but is well described by a model comprised of an irradiated accretion disc plus a stellar population with a mass ~1E6 Msun. The age of the population cannot be uniquely constrained, with both very young and very old stellar populations allowed. However, the very old solution requires excessively high levels of disc reprocessing and an extremely small disc, leading us to favour the young solution with an age of ~13 Myr. In addition, the presence of dust lanes and the lack of any nuclear activity from X-ray observations of the host galaxy lead us to propose that a gas-rich minor merger may have taken place less than ~200 Myr ago. Such a merger event would explain the presence of the intermediate mass black hole and support a young stellar population.

preprint2012arXiv

Investigating slim disk solutions for HLX-1 in ESO 243-49

The hyper luminous X-ray source HLX-1 in the galaxy ESO 243-49, currently the best intermediate mass black hole candidate, displays spectral transitions similar to those observed in Galactic black hole binaries, but with a luminosity 100-1000 times higher. We investigated the X-ray properties of this unique source fitting multi-epoch data collected by Swift, XMM-Newton & Chandra with a disk model computing spectra for a wide range of sub- and super-Eddington accretion rates assuming a non-spinning black hole and a face-on disk (i = 0 deg). Under these assumptions we find that the black hole in HLX-1 is in the intermediate mass range (~2 x 10^4 M_odot) and the accretion flow is in the sub-Eddington regime. The disk radiation efficiency is eta = 0.11 +/-0.03. We also show that the source does follow the L_X ~ T^4 relation for our mass estimate. At the outburst peaks, the source radiates near the Eddington limit. The accretion rate then stays constant around 4 x 10^(-4) M_odot yr^(-1) for several days and then decreases exponentially. Such "plateaus" in the accretion rate could be evidence that enhanced mass transfer rate is the driving outburst mechanism in HLX-1. We also report on the new outburst observed in August 2011 by the Swift-X-ray Telescope. The time of this new outburst further strengthens the ~1 year recurrence timescale.

preprint2012arXiv

LOFT: the Large Observatory For X-ray Timing

The LOFT mission concept is one of four candidates selected by ESA for the M3 launch opportunity as Medium Size missions of the Cosmic Vision programme. The launch window is currently planned for between 2022 and 2024. LOFT is designed to exploit the diagnostics of rapid X-ray flux and spectral variability that directly probe the motion of matter down to distances very close to black holes and neutron stars, as well as the physical state of ultra-dense matter. These primary science goals will be addressed by a payload composed of a Large Area Detector (LAD) and a Wide Field Monitor (WFM). The LAD is a collimated (<1 degree field of view) experiment operating in the energy range 2-50 keV, with a 10 m^2 peak effective area and an energy resolution of 260 eV at 6 keV. The WFM will operate in the same energy range as the LAD, enabling simultaneous monitoring of a few-steradian wide field of view, with an angular resolution of <5 arcmin. The LAD and WFM experiments will allow us to investigate variability from submillisecond QPO's to year-long transient outbursts. In this paper we report the current status of the project.

preprint2012arXiv

The relative and absolute timing accuracy of the EPIC-pn camera on XMM-Newton, from X-ray pulsations of the Crab and other pulsars

Reliable timing calibration is essential for the accurate comparison of XMM-Newton light curves with those from other observatories, to ultimately use them to derive precise physical quantities. The XMM-Newton timing calibration is based on pulsar analysis. However, as pulsars show both timing noise and glitches, it is essential to monitor these calibration sources regularly. To this end, the XMM-Newton observatory performs observations twice a year of the Crab pulsar to monitor the absolute timing accuracy of the EPIC-pn camera in the fast Timing and Burst modes. We present the results of this monitoring campaign, comparing XMM-Newton data from the Crab pulsar (PSR B0531+21) with radio measurements. In addition, we use five pulsars (PSR J0537-69, PSR B0540-69, PSR B0833-45, PSR B1509-58 and PSR B1055-52) with periods ranging from 16 ms to 197 ms to verify the relative timing accuracy. We analysed 38 XMM-Newton observations (0.2-12.0 keV) of the Crab taken over the first ten years of the mission and 13 observations from the five complementary pulsars. All the data were processed with the SAS, the XMM-Newton Scientific Analysis Software, version 9.0. Epoch folding techniques coupled with χ^{2} tests were used to derive relative timing accuracies. The absolute timing accuracy was determined using the Crab data and comparing the time shift between the main X-ray and radio peaks in the phase folded light curves. The relative timing accuracy of XMM-Newton is found to be better than 10^{-8}. The strongest X-ray pulse peak precedes the corresponding radio peak by 306\pm9 \mus, which is in agreement with other high energy observatories such as Chandra, INTEGRAL and RXTE. The derived absolute timing accuracy from our analysis is \pm48 \mus.

preprint2011arXiv

Pulsed Gamma Rays from the Original Millisecond and Black Widow Pulsars: a case for Caustic Radio Emission?

We report the detection of pulsed gamma-ray emission from the fast millisecond pulsars (MSPs) B1937+21 (also known as J1939+2134) and B1957+20 (J1959+2048) using 18 months of survey data recorded by the \emph{Fermi} Large Area Telescope (LAT) and timing solutions based on radio observations conducted at the Westerbork and Nançay radio telescopes. In addition, we analyzed archival \emph{RXTE} and \emph{XMM-Newton} X-ray data for the two MSPs, confirming the X-ray emission properties of PSR B1937+21 and finding evidence ($\sim 4σ$) for pulsed emission from PSR B1957+20 for the first time. In both cases the gamma-ray emission profile is characterized by two peaks separated by half a rotation and are in close alignment with components observed in radio and X-rays. These two pulsars join PSRs J0034-0534 and J2214+3000 to form an emerging class of gamma-ray MSPs with phase-aligned peaks in different energy bands. The modeling of the radio and gamma-ray emission profiles suggests co-located emission regions in the outer magnetosphere.

preprint2010arXiv

The X-ray source content of the XMM-Newton Galactic Plane Survey

We report the results of an optical campaign carried out by the XMM-Newton Survey Science Centre with the specific goal of identifying the brightest X-ray sources in the XMM-Newton Galactic Plane Survey of Hands et al. (2004). In addition to photometric and spectroscopic observations obtained at the ESO-VLT and ESO-3.6m, we used cross-correlations with the 2XMMi, USNO-B1.0, 2MASS and GLIMPSE catalogues to progress the identification process. Active coronae account for 16 of the 30 identified X-ray sources. Many of the identified hard X-ray sources are associated with massive stars emitting at intermediate X-ray luminosities of 10^32-34 erg/s. Among these are a very absorbed likely hyper-luminous star with X-ray/optical spectra and luminosities comparable with those of eta Carina, a new X-ray selected WN8 Wolf-Rayet star, a new Be/X-ray star belonging to the growing class of Gamma-Cas analogs and a possible supergiant X-ray binary of the kind discovered recently by INTEGRAL. One of the sources, XGPS-25 has a counterpart which exhibits HeII 4686 and Bowen CIII-NIII emission lines suggesting a quiescent or X-ray shielded Low Mass X-ray Binary, although its properties might also be consistent with a rare kind of cataclysmic variable (CV). We also report the discovery of three new CVs, one of which is a likely magnetic system. The soft (0.4-2.0 keV) band LogN-LogS curve is completely dominated by active stars in the flux range of 1x10^-13 to 1x10^-14 erg/cm2/s. In total, we are able to identify a large fraction of the hard (2-10 keV) X-ray sources in the flux range of 1x10^-12 to 1x10^-13 erg/cm2/s with Galactic objects at a rate consistent with that expected for the Galactic contribution only. (abridged)

preprint2002arXiv

The XMM-Newton SSC Survey of the Galactic Plane

The XMM-Newton Survey Science Center is currently conducting an optical identification programme of serendipitous EPIC sources at low galactic latitudes. The aim of this study is to quantify the various populations contributing to the overall X-ray emission of the Galaxy and elaborate identification rules that can be later applied to the bulk of the low galactic latitude EPIC detections. We report here on preliminary results from an optical campaign performed in two very low b XMM-Newton fields and discuss the contributions of the various X-ray populations. This paper is presented on behalf of the Survey Science Center and of the AXIS collaboration.