Researcher profile

N. G. Czakon

N. G. Czakon contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2015arXiv

Galaxy Cluster Scaling Relations between Bolocam Sunyaev-Zel'dovich Effect and Chandra X-ray Measurements

We present scaling relations between the integrated Sunyaev-Zel'dovich Effect (SZE) signal, $Y_{\rm SZ}$, its X-ray analogue, $Y_{\rm X}\equiv M_{\rm gas}T_{\rm X}$, and total mass, $M_{\rm tot}$, for the 45 galaxy clusters in the Bolocam X-ray-SZ (BOXSZ) sample. All parameters are integrated within $r_{2500}$. $Y_{2500}$ values are measured using SZE data collected with Bolocam, operating at 140 GHz at the Caltech Submillimeter Observatory (CSO). The temperature, $T_{\rm X}$, and mass, $M_{\rm gas,2500}$, of the intracluster medium are determined using X-ray data collected with Chandra, and $M_{\rm tot}$ is derived from $M_{\rm gas}$ assuming a constant gas mass fraction. Our analysis accounts for several potential sources of bias, including: selection effects, contamination from radio point sources, and the loss of SZE signal due to noise filtering and beam-smoothing effects. We measure the $Y_{2500}$--$Y_{\rm X}$ scaling to have a power-law index of $0.84\pm0.07$, and a fractional intrinsic scatter in $Y_{2500}$ of $(21\pm7)\%$ at fixed $Y_{\rm X}$, both of which are consistent with previous analyses. We also measure the scaling between $Y_{2500}$ and $M_{2500}$, finding a power-law index of $1.06\pm0.12$ and a fractional intrinsic scatter in $Y_{2500}$ at fixed mass of $(25\pm9)\%$. While recent SZE scaling relations using X-ray mass proxies have found power-law indices consistent with the self-similar prediction of 5/3, our measurement stands apart by differing from the self-similar prediction by approximately 5$σ$. Given the good agreement between the measured $Y_{2500}$--$Y_{\rm X}$ scalings, much of this discrepancy appears to be caused by differences in the calibration of the X-ray mass proxies adopted for each particular analysis.

preprint2003arXiv

Low-Energy Photodisintegration of the Deuteron and Big-Bang Nucleosynthesis

The photon analyzing power for the photodisintegration of the deuteron was measured for seven gamma-ray energies between 2.39 and 4.05 MeV using the linearly polarized gamma-ray beam of the High-Intensity Gamma-ray Source at the Duke Free-Electron Laser Laboratory. The data provide a stringent test of theoretical calculations for the inverse reaction, the neutron-proton radiative capture reaction at energies important for Big-Bang Nucleosynthesis. Our data are in excellent agreement with potential model and effective field theory calculations. Therefore, the uncertainty in the baryon density obtained from Big-Bang Nucleosynthesis can be reduced at least by 20%.