Source author record

N. C. Xin

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

3works
1topics
4close collaborators

Published work

3 publications

preprint2022arXiv

Determination of hyperfine splittings and Landé gJg_J factors of 5s 2S1/25s~^2S_{1/2} and 5p 2P1/2,3/25p~^2P_{1/2,3/2} states of 111,113^{111,113}Cd+^+ for a microwave frequency standard

Regarding trapped-ion microwave-frequency standards, we report on the determination of hyperfine splittings and Landé gJg_J factors of 111,113^{111,113}Cd+^+. The hyperfine splittings of the 5p 2P3/25p~^2P_{3/2} state of 111,113^{111,113}Cd+^+ ions were measured using laser-induced fluorescence spectroscopy. The Cd+^+ ions were confined in a linear Paul trap and sympathetically cooled by Ca+^+ ions. Furthermore, the hyperfine splittings and Landé gJg_J factors of the 5s 2S1/25s~^2S_{1/2} and 5p 2P1/2,3/25p~^2P_{1/2,3/2} levels of 111,113^{111,113}Cd+^+ were calculated with greater accuracy using the multiconfiguration Dirac--Hartree--Fock scheme. The measured hyperfine splittings and the Dirac--Hartree--Fock calculation values were cross-checked, thereby further guaranteeing the reliability of our results. The results provided in this work can improve the signal-to-noise ratio of the clock transition and the accuracy of the second-order Zeeman shift correction, and subsequently the stability and accuracy of the microwave frequency standard based on trapped Cd+^+ ions.

preprint2022arXiv

Progress toward a microwave frequency standard based on laser-cooled large scale 171Yb+ ion crystal

We report on progress towards a microwave frequency standard based on a laser-cooled 171Yb+ ion trap system. The electronics, lasers, and magnetic shields are integrated into a single physical package. With over 1E5 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171Yb+ microwave clock was further improved to 8.5×10−13/τ8.5 \times {10^{ - 13}}/\sqrt τ for averaging times between 10 and 1000 s.

preprint2020arXiv

Sympathetic cooling of 113^{113}Cd+^+ by laser-cooled 40^{40}Ca+^+ in a linear Paul trap for Microwave Ion Clocks

We report sympathetic cooling of 113^{113}Cd+^+ by laser-cooled 40^{40}Ca+^+ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of 113^{113}Cd+^+ ions was achieved. The temperature of these ions was measured at 90(10)90(10) mK, and the corresponding uncertainty arising from the second-order Doppler shifts was estimated to a level of 2×10−172\times10^{-17}. Up to 4.2×1054.2\times10^5 Cd+^+ ions were confined in the trap, and the confinement time constant was measured to be 84 hours. After three hours of confinement, there were still 10510^5 Cd+^+ ions present, indicating that this Ca+^+--Cd+^+ dual ion system is surprisingly stable. The ac Stark shift was induced by the Ca+^+ lasers and fluorescence, which was carefully estimated to an accuracy of 5.4(0.5)×10−175.4(0.5)\times10^{-17} using a high-accuracy \textit{ab initio} approach. The Dick-effect-limited Allan deviation was also deduced because deadtimes were shorter. These results indicate that a microwave clock based on this sympathetic cooling scheme holds promise in providing ultra-high frequency accuracy and stability.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.