Source author record

N. C. Jessen

N. C. Jessen appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2015arXiv

The Mid-Infrared Instrument for JWST, II: Design and Build

The Mid-InfraRed Instrument (MIRI) on the James Webb Space Telescope (JWST) provides measurements over the wavelength range 5 to 28.5 microns. MIRI has, within a single 'package', four key scientific functions: photometric imaging, coronagraphy, single-source low-spectral resolving power (R ~ 100) spectroscopy, and medium-resolving power (R ~ 1500 to 3500) integral field spectroscopy. An associated cooler system maintains MIRI at its operating temperature of < 6.7 K. This paper describes the driving principles behind the design of MIRI, the primary design parameters, and their realization in terms of the 'as-built' instrument. It also describes the test program that led to delivery of the tested and calibrated Flight Model to NASA in 2012, and the confirmation after delivery of the key interface requirements.

preprint2011arXiv

X-shooter, the new wide band intermediate resolution spectrograph at the ESO Very Large Telescope

X-shooter is the first 2nd generation instrument of the ESO Very Large Telescope(VLT). It is a very efficient, single-target, intermediate-resolution spectrograph that was installed at the Cassegrain focus of UT2 in 2009. The instrument covers, in a single exposure, the spectral range from 300 to 2500 nm. It is designed to maximize the sensitivity in this spectral range through dichroic splitting in three arms with optimized optics, coatings, dispersive elements and detectors. It operates at intermediate spectral resolution (R~4,000 - 17,000, depending on wavelength and slit width) with fixed echelle spectral format (prism cross-dispersers) in the three arms. It includes a 1.8"x4" Integral Field Unit as an alternative to the 11" long slits. A dedicated data reduction package delivers fully calibrated two-dimensional and extracted spectra over the full wavelength range. We describe the main characteristics of the instrument and present its performance as measured during commissioning, science verification and the first months of science operations.