Researcher profile

Mutsuko Hatano

Mutsuko Hatano contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Coherence of a charge stabilised tin-vacancy spin in diamond

Quantum information processing (QIP) with solid state spin qubits strongly depends on the efficient initialisation of the qubit's desired charge state. While the negatively charged tin-vacancy ($\text{SnV}^{-}$) centre in diamond has emerged as an excellent platform for realising QIP protocols due to long spin coherence times at liquid helium temperature and lifetime limited optical transitions, its usefulness is severely limited by termination of the fluorescence under resonant excitation [1,2,3]. Here, we unveil the underlying charge cycle of group IV-vacancy (G4V) centres and exploit it to demonstrate highly efficient initialisation of the desired negative charge state of single SnV centres while preserving long term stable optical resonances. We furthermore all-optically probe the coherence of the ground state spins by means of coherent population trapping and find a spin dephasing time of 5$μ$s. Additionally, we demonstrate proof-of-principle single shot spin state readout without the necessity of a magnetic field aligned to the symmetry axis of the defect.

preprint2022arXiv

Identical Photons from Multiple Tin-Vacancy Centers in Diamond

We report the narrow inhomogeneous distribution of the zero-phonon line from tin-vacancy (SnV) centers in diamond and the overlap of spectra from multiple separated SnV centers. Photoluminescence excitation spectroscopy measurements at a cryogenic temperature showed that SnV centers exhibit stable fluorescence and linewidths close to the Fourier transform-limited linewidth. The inhomogeneous distribution was as low as ~4 GHz, which enabled the observation of Sn isotope-dependent resonant frequencies. Owing to the narrow inhomogeneous distribution, we observed multiple SnV centers showing identical photons with almost the same wavelength and linewidth. Identical SnV centers were also observed even in different diamond samples, confirming the reliable fabrication of the high-quality SnV centers.

preprint2021arXiv

Label-free phase change detection of lipid bilayers using nanoscale diamond magnetometry

The NV center in a diamond is a quantum sensor with exceptional quality for highly sensitive nanoscale analysis of NMR spectra and thermometry. In this study, we investigate nanoscale phase change detection of lipid bilayers utilizing ensemble-averaged nuclear spin detection from small volume ~ (6 nm)$^{3}$, which was determined by the depth of the NV center. Analysis of nanoscale NMR signal confirm thickness of lipid bilayer to be 6.2 nm $\pm$ 3.4 nm with proton density of 65 proton/nm$^{3}$ verifying formation of lipid bilayer on top of diamond sample. Correlation spectroscopy from nanoscale volume reveals quantum oscillation at 3.06 MHz corresponding to the Larmor frequency of proton at an applied magnetic field of 71.8 mT. The result of the correlation spectroscopy was compared with the 2D molecular diffusion model constructed by Monte Carlo simulation combined with results from molecular dynamics simulation. There is a change in diffusion constant from 1.5 $\pm$ 0.25 nm$^{2}$/$μ$s to 3.0 $\pm$ 0.5 nm$^{2}$/$μ$s when the temperature changes from 26.5 $^\circ$C to 36.0 $^\circ$C. Our results demonstrate that simultaneous observation of changes in translational diffusion and temperature is possible in label-free measurements using nanoscale diamond magnetometry. Our method paves the way for label-free imaging of cell membranes for understanding its phase composition and dynamics.

preprint2020arXiv

Simultaneous Wide-field Imaging of Phase and Magnitude of AC Magnetic Signal Using Diamond Quantum Magnetometry

Spectroscopic analysis of AC magnetic signal using diamond quantum magnetometry is a promising technique for inductive imaging. Conventional dynamic decoupling like XY8 provides a high sensitivity of an oscillating magnetic signal with intricate dependence on magnitude and phase, complicating high throughput detection of each parameter. In this study, a simple measurement scheme for independent and simultaneous detection of magnitude and phase is demonstrated by a sequential measurement protocol. Wide-field imaging experiment was performed for an oscillating magnetic field with approximately 100$μ$m-squared observation area. Single pixel phase precision was $2.1^\circ$ for 0.76$μ$T AC magnetic signal. Our method enables potential applications including inductive inspection and impedance imaging.

preprint2020arXiv

Spectroscopic Investigations of Negatively Charged Tin-Vacancy Centres in Diamond

The recently discovered negatively charged tin-vacancy centre in diamond is a promising candidate for applications in quantum information processing (QIP). We here present a detailed spectroscopic study encompassing single photon emission and polarisation properties, the temperature dependence of emission spectra as well as a detailed analysis of the phonon sideband and Debye-Waller factor. Using photoluminescence excitation spectroscopy (PLE) we probe an energetically higher lying excited state and prove fully lifetime limited linewidths of single emitters at cryogenic temperatures. For these emitters we also investigate the stability of the charge state under resonant excitation. These results provide a detailed insight into the spectroscopic properties of the $\text{SnV}^-$ centre and lay the foundation for further studies regarding its suitability in QIP.

preprint2019arXiv

Experimental and theoretical analysis of noise strength and environmental correlation time for ensembles of nitrogen-vacancy centers in diamond

We experimentally and theoretically investigate the Hahn echo decay curve for nitrogen vacancy centers in diamond with different spin concentrations. The Hahn echo results show a non-exponential decay for low spin concentrations, while an exponential decay is dominant for high spin concentrations. By fitting the decay curve with a theoretical model, we show that both the amplitude and correlation time of the environmental noise have a clear dependence on the spin concentration. These results are essential for optimizing the NV center concentration in high-performance quantum devices, particularly quantum sensors.

preprint2018arXiv

Highly sensitive macro-scale diamond magnetometer operated by dynamical decoupling sequence with coplanar waveguide resonator

Ultimate sensitivity for quantum magnetometry using nitrogen-vacancy (NV) centers in diamond is limited by number of NV centers and coherence time. Microwave irradiation with a high and homogeneous power density for a large detection volume is necessary to achieve highly sensitive magnetometer. Here, we demonstrate a microwave resonator to enhance the power density of the microwave field and an optical system with a detection volume of 1.4e-3 mm$^3$. The strong microwave field enables us to achieve 48 ns Rabi oscillation which is sufficiently faster than the phase relaxation time of NV centers. This system combined with a decoupling pulse sequence, XY16, extends the spin coherence time (T2) up to 27 times longer than that with a spin echo method. Consequently, we obtained an AC magnetic field sensitivity of 10.8 pT/Hz$^{1/2}$ using the dynamical decoupling pulse sequence.