Researcher profile

Murat Tahtali

Murat Tahtali contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - Baseline
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Elimination of Central Artefacts of L-SPECT with Modular Partial Ring Detectors by Shifting Center of Scanning

The Lightfield Single Photon Emission Computed Tomography (L-SPECT) system is developed to overcome some of the drawbacks in conventional SPECT by applying the idea of plenoptic imaging. This system displayed improved performance in terms of reduced information loss and scanning time when compared to the SPECT system which has a conventional collimator. The SPECT system is transformed into L-SPECT system by replacing the conventional collimators with micro-range multi-pinhole arrays. The field of view (FOV) of the L-SPECT system is enhanced by reshaping the detector head into ring-type by tiling small detector modules. The L-SPECT system with modular partial ring detectors (MPRD L-SPECT) exhibits cylindrical artefacts during volumetric reconstruction. Hence, here the work is focused to remove the cylindrical artefacts in the reconstruction of the examined objects by changing the scanning orbit. The enhancement is done such that the center of scanning of the L-SPECT system with MPRD L-SPECT is shifted at different values. The reconstruction quality of MPRD L-SPECT with and without center shifting is evaluated in terms of the Full Width at Half Maximum (FWHM) and Modulation Transfer Function (MTF). Moreover, the visual comparison is also examined. The results indicate that center shifting of MPRD L-SPECT overcomes the problem of the central artefact with improved FWHM. By increasing MPRD's scanning center shift gap, the spatial resolution can be further improved.

preprint2015arXiv

Adaptive Adjustment of Relaxation Parameters for Algebraic Reconstruction Technique and its Possible Application to Sparsity Prior X-ray CT Reconstruction

In this paper, we systematically evaluate the performance of adaptive adjustment of the relaxation parameters of various iterative algorithms for X-ray CT reconstruction relying on sparsity priors. Sparsity prior has been found to be an efficient strategy in CT reconstruction where significantly fewer attenuation measurements are available. Sparsity prior CT reconstruction relies on iterative algorithms such as the algebraic reconstruction technique (ART) to produce a crude reconstruction based on which a sparse approximation is performed. Data driven adjustment of relaxation has been found to ensure better convergence than traditional relaxation for ART. In this paper, we study the performance of such data driven relaxation on a (CS) compressed sensing environment. State-of-the-art algorithms are implemented and their performance analyzed in regard to conventional and data-driven relaxation. Experiments are performed both on simulated and real environments. For the simulated case, experiments are conducted with and without the presence of noise. Correlation coefficients, root mean square error, structural similarity index and perceptual dissimilarity metric were used for the quantitative comparisons of the results. Experiments reveal that data driven relaxation also ensures overall better quality reconstruction in a CS environment compared to traditional relaxation. However, when the data are corrupted by noise, inconsistencies emerge in the convergence unless a threshold is imposed on the maximum amendments. Data driven relaxation seems a logical choice to more rapidly reach the solution. In a compressed sensing environment, especially when the data are corrupted by noise, a threshold to specify the maximum amendments needs to be specified. Experimentally, we have set the threshold as 20% of the previous value and thus have ensured more consistency in the convergence.

preprint2014arXiv

CT Reconstruction from Simultaneous Projections: A Step towards Capturing CT in One Go

This paper focuses on minimizing the time requirement for CT capture through innovative simultaneous x-ray capture method. The state-of-the-art CT imaging methodology captures a sequence of projections during which the internal organ movements may lead to poor reconstruction due to motion artefacts. Traditional CT scanners' minimize such effect by taking more projections than necessary. In this work we focus on an innovative CT capture method that captures projections simultaneously, promising super fast scans along with possible radiation dose reductions. While the simultaneous CT capture model has already been proposed in our earlier work 'Multi-axial CT Reconstruction from Few View Projections' (in SPIE Optical Engineering and Applications, pp. 85000A-85000A. International Society for Optics and Photonics, 2012) and 'A New Imaging Method for Real-time 3D X-ray Reconstruction' (in SPIE Medical Imaging, pp. 86685G-86685G. International Society for Optics and Photonics, 2013), in this work we enhance the model through better initialization along with prior smoothing before successive iterations of the iterative algorithms. We also elaborate the model considering different X-ray source/detector configurations. Results show that it is possible reconstruct a cross-section slice by considering only four angular projections. With eight projections, the reconstruction is further improved. The main promising matter about this method is that, all these projections (i.e. four or eight) can in principle be captured simultaneously, implying CT capture in one go just like a chest X-ray.

preprint2014arXiv

Evaluation of Spatial Resolution and Noise Sensitivity of sLORETA Method for EEG Source Localization Using Low-Density Headsets

Electroencephalography (EEG) has enjoyed considerable attention over the past century and has been applied for diagnosis of epilepsy, stroke, traumatic brain injury and other disorders where 3D localization of electrical activity in the brain is potentially of great diagnostic value. In this study we evaluate the precision and accuracy of spatial localization of electrical activity in the brain delivered by a popular reconstruction technique sLORETA applied to EEG data collected by two commonly used low-density headsets with 14 and 19 measurement channels, respectively. Numerical experiments were performed for a realistic head model obtained by segmentation of MRI images. The EEG source localization study was conducted with a simulated single active dipole, as well as with two spatially separated simultaneously active dipoles, as a function of dipole positions across the neocortex, with several different noise levels in the EEG signals registered on the scalp. The results indicate that while the reconstruction accuracy and precision of the sLORETA method are consistently high in the case of a single active dipole, even with the low-resolution EEG configurations considered in the present study, successful localization is much more problematic in the case of two simultaneously active dipoles. The quantitative analysis of the width of the reconstructed distributions of the electrical activity allows us to specify the lower bound for the spatial resolution of the sLORETA-based 3D source localization in the considered cases.