Source author record

Mostafa Sahraei-Ardakani

Mostafa Sahraei-Ardakani appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

Targeted Hardening of Electric Distribution System for Enhanced Resilience against Earthquakes

Securing the power system from catastrophic natural disasters is a rising problem in power system operation and planning. This paper particularly considers earthquake and aims to evaluate and improve the resilience of power distribution networks by developing a novel hardware hardening framework. In the proposed framework, fragility curves of the network equipment are used to represent equipment failure probabilities when facing an earthquake, and failure scenarios of the distribution network are obtained via the Monte Carlo method. Based on the distribution network topology and the locations of essential loads, various hardware hardening strategies are determined within the proposed framework. Through a series of resilience and economic analyses, the optimal hardening strategy is determined to improve the resilience and supply the essential loads during and after the earthquake. The efficacy of the proposed approach is examined through simulations on an IEEE 33-bus test feeder.

preprint2021arXiv

Cascading Failure Mitigation via Transmission Switching

After decades of research, cascading blackouts remain one of the unresolved challenges in the bulk power system operations. A new perspective for measuring the susceptibility of the system to cascading failures is clearly needed. The newly developed concept of system stress metrics may be able to provide new insights into this problem. The method measures stress as susceptibility to cascading failures by analyzing the network structure and electrical properties. This paper investigates the effectiveness of transmission switching in reducing the risk of cascading failures, measured in system stress metrics. Based on line-outage distribution factors, an algorithm is developed to identify and test the switching candidates quickly. A case study analyzing different stress metrics on the IEEE 118-bus test system is presented. The results show that transmission switching identified by our proposed algorithm could be used in preventive as well as corrective mechanisms to reduce the system's susceptibility to cascading failures. Contrary to the conventional operation wisdom that switching lines out of service jeopardizes reliability, our results suggest the opposite; system operators can often use transmission switching, when the system is under stress, as a tool to reduce the risk of cascading failures.

preprint2019arXiv

Chance-Constrained Shrunken-Primal-Dual Subgradient (CC-SPDS) Approach for Decentralized Electric Vehicle Charging Control

In this paper, we develop a chance-constrained decentralized electric vehicle (EV) charging control framework to achieve "valley-filling" meanwhile meeting individual charging requirements and satisfying distribution network constraints. The control design is formulated as an optimization problem with a stochastic non-separable objective function and globally coupled chance constraints. We propose a novel chance-constrained shrunken-primal-dual subgradient (CC-SPDS) algorithm to support the chance-constrained decentralized control scheme and verify its efficacy and convergence with a representative distribution network model.

preprint2016arXiv

Real-Time Contingency Analysis with Corrective Transmission Switching - Part I: Methodology

Transmission switching (TS) has gained significant attention recently. However, barriers still remain and must be overcome before the technology can be adopted by the industry. The state of the art challenges include AC feasibility and performance, computational complexity, the ability to handle large-scale real power systems, and dynamic stability. This two-part paper investigates these challenges by developing an AC TS-based real-time contingency analysis (RTCA) tool that can handle large-scale systems within a reasonable time. The tool proposes multiple corrective switching actions, after detection of a contingency with potential violations. To reduce the computational complexity, three heuristic algorithms are proposed to generate a small set of candidates for switching. Parallel computing is implemented to further speed up the solution time. Furthermore, stability analysis is performed to check for dynamic stability of proposed TS solutions. Part I of the paper presents a comprehensive literature review and the methodology. The promising results, tested on the Tennessee Valley Authority (TVA) system and actual energy management system (EMS) snapshots from Pennsylvania New Jersey Maryland (PJM) and the Electric Reliability Council of Texas (ERCOT), are presented in Part II. It is concluded that RTCA with corrective TS significantly reduces potential post-contingency violations and is ripe for industry adoption.

preprint2016arXiv

Real-Time Contingency Analysis with Corrective Transmission Switching - Part II: Results and Discussion

This paper presents the performance of an AC transmission switching (TS) based real-time contingency analysis (RTCA) tool that is introduced in Part I of this paper. The approach quickly proposes high quality corrective switching actions for relief of potential post-contingency network violations. The approach is confirmed by testing it on actual EMS snapshots of two large-scale systems, the Electric Reliability Council of Texas (ERCOT) and the Pennsylvania New Jersey Maryland (PJM) Interconnection; the approach is also tested on data provided by the Tennessee Valley Authority (TVA). The results show that the tool effectively reduces post-contingency violations. Fast heuristics are used along with parallel computing to reduce the computational difficulty of the problem. The tool is able to handle the PJM system in about five minutes with a standard desktop computer. Time-domain simulations are performed to check system stability with corrective transmission switching (CTS). In conclusion, the paper shows that corrective switching is ripe for industry adoption. CTS can provide significant reliability benefits that can be translated into significant cost savings.