Source author record

Mohamed Serry

Mohamed Serry appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
9topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2021arXiv

Over-approximating reachable tubes of linear time-varying systems

We present a method to over-approximate reachable tubes over compact time-intervals, for linear continuous-time, time-varying control systems whose initial states and inputs are subject to compact convex uncertainty. The method uses numerical approximations of transition matrices, is convergent of first order, and assumes the ability to compute with compact convex sets in finite dimension. We also present a variant that applies to the case of zonotopic uncertainties, uses only linear algebraic operations, and yields zonotopic over-approximations. The performance of the latter variant is demonstrated on an example.

preprint2020arXiv

Convergent Under-Approximations of Reachable Sets and Tubes for Linear Uncertain Systems

In this note, we propose a method to under-approximate finite-time reachable sets and tubes for a class of continuous-time linear uncertain systems. The class under consideration is the linear time-varying (LTV) class with integrable time-varying system matrices and uncertain initial and input values belonging to known convex compact sets. The proposed method depends upon the iterative use of constant-input reachable sets which results in convergent under-approximations in the sense of Hausdorff distance. We illustrate our approach through two numerical examples.

preprint2019arXiv

Performance-Enhanced Non-Enzymatic Glucose Sensor Based on Graphene-Heterostructure

This study proposes a novel design of glucose sensor with enhanced selectivity and sensitivity by using graphene Schottky diodes, which is composed of Graphene (G)/Platinum Oxide (PtO)/n-Silicon (Si) heterostructure. The sensor was tested with different glucose concentrations and interfering solutions to investigate its sensitivity and selectivity. Different structures of the device were studied by adjusting the platinum oxide film thickness to investigate its catalytic activity. It was found that the film thickness plays a significant role in the efficiency of glucose oxidation and hence in overall device sensitivity. 0.8-2 uA output current was obtained in the case of 4-10 mM with a sensitivity of 0.2 uA/mM.cm2. Besides, results have shown that 0.8 uA and 15 uA were obtained by testing 4 mM glucose on two different PtO thicknesses, 30 nm, and 50 nm, respectively. The sensitivity of the device was enhanced by 150% (i.e., up to 30 uA/mM.cm2) by increasing the PtO layer thickness. This was attributed to both the increase of the number of active sites for glucose oxidation as well as the increase in the graphene layer thickness, which leads to enhanced charge carriers concentration and mobility. Moreover, theoretical investigations were conducted using the Density Function Theory (DFT) to understand the detection method and the origins of selectivity better. The working principle of the sensors puts it in a competitive position with other non-enzymatic glucose sensors. DFT calculations provided a qualitative explanation of the charge distribution across the graphene sheet within a system of a platinum substrate with D-glucose molecules above. The proposed G/PtO/n-Si heterostructure has proven to satisfy these factors, which opens the door for further developments of more reliable non-enzymatic glucometers for continuous glucose monitoring systems.

preprint2015arXiv

Non-Enzymatic Graphene-Based Biosensors for Continuous Glucose Monitoring

A novel mediator-free, non-enzymatic electrochemical sensor, based on a graphene-Schottky junction, was fabricated for glucose detection. The sensor offers a promising alternative to the conventional enzyme-catalyzed electrochemical continuous glucose monitoring systems (CGM), as it overcomes many of the drawbacks attributed to the enzymatic nature; namely, irreversibility, drift, and interference with body fluids, which affect their accuracy, reliability and longevity. Enhanced performance of the sensors is demonstrated through the band interaction at the graphene-Schottky junction, which yields stronger forward/reverse currents in response to 50 μL glucose drop. Under optimized conditions, the linear response of the sensor to glucose concentration was valid in the range from 0 to 15 mmol/L with a detection limit of 0.5 mmol/L. The results indicated that the proposed sensor provided a highly sensitive, more facile method with good reproducibility for continuous glucose detection.