Researcher profile

Mohamed Serry

Mohamed Serry contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2021arXiv

Over-approximating reachable tubes of linear time-varying systems

We present a method to over-approximate reachable tubes over compact time-intervals, for linear continuous-time, time-varying control systems whose initial states and inputs are subject to compact convex uncertainty. The method uses numerical approximations of transition matrices, is convergent of first order, and assumes the ability to compute with compact convex sets in finite dimension. We also present a variant that applies to the case of zonotopic uncertainties, uses only linear algebraic operations, and yields zonotopic over-approximations. The performance of the latter variant is demonstrated on an example.

preprint2020arXiv

Convergent Under-Approximations of Reachable Sets and Tubes for Linear Uncertain Systems

In this note, we propose a method to under-approximate finite-time reachable sets and tubes for a class of continuous-time linear uncertain systems. The class under consideration is the linear time-varying (LTV) class with integrable time-varying system matrices and uncertain initial and input values belonging to known convex compact sets. The proposed method depends upon the iterative use of constant-input reachable sets which results in convergent under-approximations in the sense of Hausdorff distance. We illustrate our approach through two numerical examples.

preprint2019arXiv

Performance-Enhanced Non-Enzymatic Glucose Sensor Based on Graphene-Heterostructure

This study proposes a novel design of glucose sensor with enhanced selectivity and sensitivity by using graphene Schottky diodes, which is composed of Graphene (G)/Platinum Oxide (PtO)/n-Silicon (Si) heterostructure. The sensor was tested with different glucose concentrations and interfering solutions to investigate its sensitivity and selectivity. Different structures of the device were studied by adjusting the platinum oxide film thickness to investigate its catalytic activity. It was found that the film thickness plays a significant role in the efficiency of glucose oxidation and hence in overall device sensitivity. 0.8-2 uA output current was obtained in the case of 4-10 mM with a sensitivity of 0.2 uA/mM.cm2. Besides, results have shown that 0.8 uA and 15 uA were obtained by testing 4 mM glucose on two different PtO thicknesses, 30 nm, and 50 nm, respectively. The sensitivity of the device was enhanced by 150% (i.e., up to 30 uA/mM.cm2) by increasing the PtO layer thickness. This was attributed to both the increase of the number of active sites for glucose oxidation as well as the increase in the graphene layer thickness, which leads to enhanced charge carriers concentration and mobility. Moreover, theoretical investigations were conducted using the Density Function Theory (DFT) to understand the detection method and the origins of selectivity better. The working principle of the sensors puts it in a competitive position with other non-enzymatic glucose sensors. DFT calculations provided a qualitative explanation of the charge distribution across the graphene sheet within a system of a platinum substrate with D-glucose molecules above. The proposed G/PtO/n-Si heterostructure has proven to satisfy these factors, which opens the door for further developments of more reliable non-enzymatic glucometers for continuous glucose monitoring systems.