Source author record

Milorad Bojić

Milorad Bojić appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2013arXiv

Performances of Low Temperature Radiant Heating Systems

Low temperature heating panel systems offer distinctive advantages in terms of thermal comfort and energy consumption, allowing work with low exergy sources. The purpose of this paper is to compare floor, wall, ceiling, and floor-ceiling panel heating systems in terms of energy, exergy and CO2 emissions. Simulation results for each of the analyzed panel system are given by its energy (the consumption of gas for heating, electricity for pumps and primary energy) and exergy consumption, the price of heating, and its carbon dioxide emission. Then, the values of the air temperatures of rooms are investigated and that of the surrounding walls and floors. It is found that the floor-ceiling heating system has the lowest energy, exergy, CO2 emissions, operating costs, and uses boiler of the lowest power. The worst system by all these parameters is the classical ceiling heating

preprint2012arXiv

Energy, cost, and CO 2 emission comparison between radiant wall panel systems and radiator systems

The main goal of this paper is to evaluate the possibility of application or replacement of radiators with low-temperature radiant panels. This paper shows the comparison results of operations of 4 space heating systems: the low-temperature radiant panel system without any additional thermal insulation of external walls (PH-WOI), the low-temperature radiant panel system with additional thermal insulation of external walls (PH-WI), the radiator system without any additional thermal insulation of external walls (the classical heating system) (RH-WOI), and the radiator system with additional thermal insulation of external walls (RH-WI). The operation of each system is simulated by software EnergyPlus. The investigation shows that the PH-WI gives the best results. The RH-WOI has the largest energy consumption, and the largest pollutant emission. However, the PH-WI requires the highest investment.