Adaptive Real-Time Grid Operation via Online Feedback Optimization with Sensitivity Estimation

In this paper we propose an approach based on an Online Feedback Optimization (OFO) controller with grid input-output sensitivity estimation for real-time grid operation, e.g., at subsecond time scales. The OFO controller uses grid measurements as feedback to update the value of the controllable elements in the grid, and track the solution of a time-varying AC Optimal Power Flow (AC-OPF). Instead of relying on a full grid model, e.g., grid admittance matrix, OFO only requires the steady-state sensitivity relating a change in the controllable inputs, e.g., power injections set-points, to a change in the measured outputs, e.g., voltage magnitudes. Since an inaccurate sensitivity may lead to a model-mismatch and jeopardize the performance, we propose a recursive least-squares estimation that enables OFO to learn the sensitivity from measurements during real-time operation, turning OFO into a model-free approach. We analytically certify the convergence of the proposed OFO with sensitivity estimation, and validate its performance on a simulation using the IEEE 123-bus test feeder, and comparing it against a state-of-the-art OFO with constant sensitivity.

preprint2022arXiv

Cross-layer Design for Real-Time Grid Operation: Estimation, Optimization and Power Flow

In this paper, we propose a combined Online Feedback Optimization (OFO) and dynamic estimation approach for a real-time power grid operation under time-varying conditions. A dynamic estimation uses grid measurements to generate the information required by an OFO controller, that incrementally steers the controllable power injections set-points towards the solutions of a time-varying AC Optimal Power Flow (AC-OPF) problem. More concretely, we propose a quadratic programming-based OFO that guarantees satisfying the grid operational constraints, like admissible voltage limits. Within the estimation, we design an online power flow solver that efficiently computes power flow approximations in real time. Finally, we certify the stability and convergence of this combined approach under time-varying conditions, and we validate its effectiveness on a simulation with a test feeder and high resolution consumption data.

preprint2020arXiv

Sieving out Unnecessary Constraints in Scenario Optimization with an Application to Power Systems

Many optimization problems incorporate uncertainty affecting their parameters and thus their objective functions and constraints. As an example, in chance-constrained optimization the constraints need to be satisfied with a certain probability. To solve these problems, scenario optimization is a well established methodology that ensures feasibility of the solution by enforcing it to satisfy a given number of samples of the constraints. The main theoretical results in scenario optimization provide the methods to determine the necessary number of samples, or to compute the risk based on the number of so-called support constraints. In this paper, we propose a methodology to remove constraints after observing the number of support constraints and the consequent risk. Additionally, we show the effectiveness of the approach with an illustrative example and an application to power distribution grid management when solving the optimal power flow problem. In this problem, uncertainty in the loads converts the admissible voltage limits into chance-constraints.