Researcher profile

Matthijs H. S. de Buck

Matthijs H. S. de Buck contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
1topics
3close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Head-and-neck multi-channel B1+ mapping and carotid arteries RF shimming using a parallel transmit head coil

Purpose: Neurovascular MRI suffers from a rapid drop in B1+ into the neck when using transmit head coils at 7T. One solution to improving B1+ magnitude in the major feeding arteries in the neck is to use custom RF shims on parallel transmit (pTx) head coils. However, calculating such shims requires robust multi-channel B1+ maps in both the head and the neck, which is challenging due to low RF penetration into the neck, limited dynamic range of multi-channel B1+ mapping techniques, and B0 sensitivity. We therefore sought a robust large-dynamic-range pTx field mapping protocol, and tested whether RF shimming can improve carotid artery B1+ in practice. Methods: A pipeline is presented that combines B1+ mapping data acquired using circularly polarized (CP-) and CP2-mode RF shims at multiple voltages. The pipeline was evaluated by comparing the predicted and measured B1+ for multiple random transmit shims, and by assessing the ability of RF shimming to increase the B1+ in the carotid arteries. Results: The proposed method achieved good agreement between predicted and measured B1+ in both the head and the neck. The B1+ magnitude in the carotid arteries can be increased by 42% using tailored RF shims or by 37% using universal RF shims, while also improving the RF homogeneity compared to CP mode. Conclusion: B1+ in the neck can be increased using RF shims calculated from multi-channel B1+ maps in both the head and the neck. This can be achieved using universal phase-only RF shims, facilitating easy implementation in existing sequences.

preprint2020arXiv

An investigation into the minimum number of tissue groups required for 7T in-silico parallel transmit electromagnetic safety simulations in the human head

Purpose: Safety limits for the permitted Specific Absorption Rate (SAR) place restrictions on pulse sequence design, especially at ultra-high fields ($\geq 7$ tesla). Due to inter-subject variability, the SAR is usually conservatively estimated based on standard human models that include an applied safety margin to ensure safe operation. One approach to reducing the restrictions is to create more accurate subject-specific models from their segmented MR images. This study uses electromagnetic simulations to investigate the minimum number of tissue groups required to accurately determine SAR in the human head. Methods: Tissue types from a fully characterized electromagnetic human model with 47 tissue types in the head and neck region were grouped into different tissue clusters based on the conductivities, permittivities, and mass densities of the tissues. Electromagnetic simulations of the head model inside a parallel transmit (pTx) head coil at 7T were used to determine the minimum number of required tissue clusters to accurately determine the subject-specific SAR. The identified tissue clusters were then evaluated using two additional well-characterized electromagnetic human models. Results: A minimum of 4 clusters plus air was found to be required for accurate SAR estimation. These tissue clusters are centered around gray matter, fat, cortical bone, and cerebrospinal fluid. For all three simulated models the pTx maximum 10gSAR was consistently determined to within an error of <12% relative to the full 47-tissue model. Conclusion: A minimum of 4 clusters plus air are required to produce accurate personalized SAR simulations of the human head when using pTx at 7T.