Researcher profile

Matthias Wessling

Matthias Wessling contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
9works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

A mini-module with built-in spacers for high-throughput ultrafiltration

Ultrafiltration membrane modules suffer from a permeate flow decrease arising during filtration and caused by concentration polarization and fouling in, e.g., fermentation broth purification. Such performance losses are frequently mitigated by manipulating the hydrodynamic conditions at the membrane-fluid interface using, e.g., mesh spacers acting as static mixers. This additional element increases manufacturing complexity while improving mass transport in general, yet accepting their known disadvantages such as less transport in dead zones. However, the shape of such spacers is limited to the design of commercially available spacer geometries. Here, we present a methodology to design an industrially relevant mini-module with an optimized built-in 3D spacer structure in a flat-sheet ultrafiltration membrane module to eliminate the spacer as a separate part. Therefore, the built-in structures have been conceptually implemented through an in-silico design in compliance with the specifications for an injection molding process. Ten built-in structures were investigated in a digital twin of the mini-module by 3D-CFD simulations to select two options, which were then compared to the empty feed channel regarding mass transfer. Subsequently, the simulated flux increase was experimentally verified during bovine serum albumin (BSA) filtration. The new built-in sinusoidal corrugation outperforms conventional mesh spacer inlays by up to 30% higher permeation rates. The origin of these improvements is correlated to the flow characteristics inside the mini-module as visualized online and in-situ by low-field and high-field magnetic resonance imaging velocimetry (flow-MRI) during pure water permeation.

preprint2022arXiv

Cell barrier characterization in transwell inserts by electrical impedance spectroscopy

We describe an impedance-based method for cell barrier integrity testing. A four-electrode electrical impedance spectroscopy (EIS) setup can be realized by simply connecting a commercial chopstick-like electrode (STX-1) to a potentiostat allowing monitoring cell barriers cultivated in transwell inserts. Subsequent electric circuit modeling of the electrical impedance results the capacitive properties of the barrier next to the well-known transepithelial electrical resistance (TEER). The versatility of the new method was analyzed by the EIS analysis of a Caco-2 monolayer in response to (a) different membrane coating materials, (b) two different permeability enhancers ethylene glycol-bis(2-aminoethylether)-N,N,N',N'-tetraacetic acid (EGTA) and saponin, and (c) sonoporation. For the different membrane coating materials, the TEERs of the standard and new protocol coincide and increase during cultivation, while the capacitance shows a distinct maximum for three different surface materials (no coating, Matrigel, and collagen I). The permeability enhancers cause a decline in the TEER value, but only saponin alters the capacitance of the cell layer by two orders of magnitude. Hence, cell layer capacitance and TEER represent two independent properties characterizing the monolayer. The use of commercial chopstick-like electrodes to access the impedance of a barrier cultivated in transwell inserts enables remarkable insight into the behavior of the cellular barrier with no extra work for the researcher. This simple method could evolve into a standard protocol used in cell barrier research.

preprint2022arXiv

Direct 3D observation and unraveling of electroconvection phenomena during concentration polarization at ion-exchange membranes

A decade ago, two-dimensional microscopic flow visualization proved the theoretically predicted existence of electroconvection roles as well as their decisive role in destabilizing the concentration polarization layer at ion-selective fluid/membrane interfaces. Electroconvection induces chaotic flow vortices injecting volume having bulk concentration into the ion-depleted diffusion layer at the interface. Experimental quantification of these important flow patterns have so far only been carried out in 2D. Numerical direct simulations suggest 3D features, yet experimental proof is lacking. 3D simulations are also limited in covering extended spacial and temporal scales. This study presents a new comprehensive experimental method for the time-resolved recording of the 3D electroconvective velocity field near a cation-exchange membrane. For the first time, the spatio-temporal velocity field can be visualized in 3D at multiples of the overlimiting current density. In contrast to today's simulations, these experiments cover length and time scales typical for actual electrodialytic membrane processes. We visualize coherent vortex structures and reveal the changes in the velocity field and its statistics during the transition from vortex rolls to vortex rings with increasing current density. The transition is characterized by changes in the rotational direction, mean square velocity, and temporal energy spectrum with only little influence on the spatial spectrum. These findings indicate a more significant impact of EC's structural change on the mean square velocities and temporal spectra than on the spatial spectra. This knowledge is a prerequisite for engineering ion-selective surfaces that will enable the operation of electrically driven processes beyond the diffusion-limited Nernst regime.

preprint2022arXiv

Flow-electrode capacitive deionization enables continuous and energy-efficient brine concentration

Many industrial and agricultural applications require the treatment of water streams containing high concentrations of ionic species for closing material cycles. High concentration factors are often desired, but hard to achieve with established thermal or membrane-based water treatment technologies at low energy consumptions. Capacitive deionization processes are normally assumed as relevant for the treatment of low salinity solutions only. Flow-electrode capacitive deionization (FCDI), on the other hand, is an electrically driven water desalination technology, which allows the continuous desalination and concentration of saline water streams even at elevated salinities. Ions are adsorbed electrostatically in pumpable carbon flow electrodes, which enable a range of new process designs. In this article, it is shown that continuously operated FCDI systems can be applied for the treatment of salt brines. Concentrations of up to 291.5~g/L NaCl were reached in the concentrate product stream. Based on this, FCDI is a promising technology for brine treatment and salt recovery. Additionally, a reduction of the energy demand by more than 70% is demonstrated by introducing multiple cell pairs into a continuous FCDI system. While the economic feasibility is not investigated here, the results show that FCDI systems may compete with established technologies regarding their energy demand.

preprint2022arXiv

How does porosity heterogeneity affect the transport properties of multibore filtration membranes?

The prediction of pressure and flow distributions inside porous membranes is important if the geometry deviates from single-bore tubular geometries. This task remains challenging, especially when considering local porosity variations caused by lumen- and shell-side membrane skins and macro- and micro-void structures, all of them present in multibore membranes. This study analyzes pure water forward and reverse permeation and backwashing phenomena for a polymeric multibore membrane with spatially-varying porosity and permeability properties using computational fluid dynamics simulations. The heterogeneity of porosity distribution is experimentally characterized by scanning electron microscopy scans and reconstructed cuboids of X-ray micro-computed tomography scans. The reconstructed cuboids are used to determine porosity, pore size distribution, and intrinsic permeability in the membrane's porous structure in all spatial directions. These position-dependent properties are then applied to porous media flow simulations of the whole membrane domain with different properties for separation layer, support structure, and outside skin layer. Various cases mimicking the pure water permeation, fouling, and backwashing behavior of the membrane are simulated and compared to previously obtained MRI measurements. This work reveals (a) anisotropic permeability values and isoporosity in all directions and (b) differing contributions of each lumen channel to the total membrane performance, depending on the membrane-skin's properties. This study encourages to pertain the quest of understanding the interaction of spatially distributed membrane properties and the overall membrane module performance of multibore membranes.

preprint2022arXiv

In-situ investigation of wetting patterns in polymeric multibore membranes via magnetic resonance imaging

Wetting of the membrane to displace air or conditioning liquids is important to exploit the complex porosity of a filtration membrane. This study reveals the details of wetting in multibore membrane-based filtration modules. Using magnetic resonance imaging (MRI), we quantify the fluid distribution patterns during initial membrane wetting in dead-end permeation mode. The spatio-temporal evolution of aqueous copper sulfate solution wetting the membrane fibers was investigated as a function of the applied flux, packing density, and position along the membrane module length. Three initial wetting conditions were examined: delivery-state membranes, ethanol-washed and dried (air-filled) membranes, and ethanol-filled membranes. Significant changes in wetting patterns were observed due to interfacial and polymer swelling effects. This in-situ investigation reveals a slow wetting progression over six hours and more to obtain complete wetting, even at high fluxes of 200 LMH. However, an increased flux leads to faster wetting kinetics as the evolving wetting patterns are flux dependent. The packing density of the multibore fibers additionally impacts the wetting kinetics by shifting the prevalent pressure conditions. Although in dead-end mode, the wetting progression is non-uniform along the membrane module length. In addition to this parameter study, different pre-wetting agents' effect on the displacement behavior was investigated in depth. This study helps to understand (a) complex wetting phenomena inside multibore membranes in dead-end filtration, (b) the membranes' interaction with their surroundings due to neighboring membranes, and (c) the effect of the used fluid system for displacement on the resulting wetting patterns.

preprint2022arXiv

Membrane-electrode assemblies for flow-electrode capacitive deionization

Scale-up of flow-electrode capacitive deionization is hindered due to the reliance on thick brittle graphite current collectors. Inspired by developments of electrochemical technologies we present the use of flexible membrane electrode assemblies (MEA) to solve these limitations. We tested different carbon-fiber fabrics as current collectors and laminated them successfully with ion-exchange membranes. The use of thinner ion-exchange membranes is now possible due to the reinforcement with the carbon fiber fabric. Desalination experiments reveal that a MEA setup can achieve salt transfer rates equal to standard setups. Hence, we deduce that charge percolation also acts outside the electric field. In a single point of contact, ionic and electric charges are exchanged at the carbon surface of the MEA. The use of thinner membranes leads to a reduced potential drop. Together with a more homogeneous electric field across the feed water section, this can compensate for the reduction of contact surface between flow electrode and current collector.

preprint2009arXiv

Evaporation-triggered Wetting Transition for Water Droplets upon Hydrophobic Microstructures

When placed on rough hydrophobic surfaces, water droplets of diameter larger than a few millimeters can easily form pearls, as they are in the Cassie-Baxter state with air pockets trapped underneath the droplet. Intriguingly, a natural evaporating process can drive such a Fakir drop into a completely wetting (Wenzel) state. Our microscopic observations with simultaneous side and bottom views of evaporating droplets upon transparent hydrophobic microstructures elucidate the water-filling dynamics and the mechanism of this evaporation-triggered transition. For the present material the wetting transition occurs when the water droplet size decreases to a few hundreds of micrometers in radius. We present a general global energy argument which estimates the interfacial energies depending on the drop size and can account for the critical radius for the transition.

preprint2009arXiv

Quantifying effective slip length over micropatterned hydrophobic surfaces

We employ micro-particle image velocimetry ($μ$-PIV) to investigate laminar micro-flows in hydrophobic microstructured channels, in particular the slip length. These microchannels consist of longitudinal micro-grooves, which can trap air and prompt a shear-free boundary condition and thus slippage enhancement. Our measurements reveal an increase of the slip length when the width of the micro-grooves is enlarged. The result of the slip length is smaller than the analytical prediction by Philip et al. [1] for an infinitely large and textured channel comprised of alternating shear-free and no-slip boundary conditions. The smaller slip length (as compared to the prediction) can be attributed to the confinement of the microchannel and the bending of the meniscus (liquid-gas interface). Our experimental studies suggest that the curvature of the meniscus plays an important role in microflows over hydrophobic micro-ridges.