Source author record

Mathias Mikkelsen

Mathias Mikkelsen appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Connecting scrambling and work statistics for short-range interactions in the harmonic oscillator

We investigate the relationship between information scrambling and work statistics after a quench for the paradigmatic example of short-range interacting particles in a one-dimensional harmonic trap, considering up to five particles numerically. In particular, we find that scrambling requires finite interactions, in the presence of which the long-time average of the squared commutator for the individual canonical operators is directly proportional to the variance of the work probability distribution. In addition to the numerical results, we outline the mathematical structure of the N-body system which leads to this outcome. We thereby establish a connection between the scrambling properties and the induced work fluctuations, with the latter being an experimental observable that is directly accessible in modern cold atom experiments.

preprint2022arXiv

Piezo-Electric Shear Rheometry: Further developments in experimental implementation and data extraction

The Piezo-electric Shear Gauge (PSG) [Christensen & Olsen, Rev. Sci. Instrum. 66, 5019, 1995] is a rheometric technique developed to measure the complex shear modulus of viscous liquids near their glass transition temperature. We report recent advances to the PSG technique: 1) The data extraction procedure is optimized which extends the upper limit of the frequency range of the method to between 50 and 70 kHz. 2) The measuring cell is simplified to use only one piezo-electric ceramic disc instead of three. We present an implementation of this design intended for liquid samples. Data obtained with this design revealed that a soft extra spacer is necessary to allow for thermal contraction of the sample in the axial direction. Model calculations show that flow in the radial direction is hindered by the confined geometry of the cell when the liquid becomes viscous upon cooling. The method is especially well-suited for -- but not limited to -- glassy materials.