Source author record

Marwan Channab

Marwan Channab appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2023arXiv

Label-free detection of miRNAs: role of probe design and bioassay configuration in Surface Enhanced Raman Scattering based biosensors

Accurate design of labelled oligo probes for the detection of miRNA biomarkers by Surface Enhanced Raman Scattering (SERS) may improve the exploitation of the plasmonic enhancement. This work, thus, critically investigates the role of probe labelling configuration on the performance of SERS based bioassays for miRNA quantitation. To this aim, highly efficient SERS substrates based on Ag-decorated porous silicon/PDMS membranes are functionalized according to two different bioassays relying on a one-step or two-step hybridization of the target miRNA with oligonucleotide probes. The detection configuration is varied, exploring the impact of the position of the Raman reporter along the oligo sequence and of the reporter identity on bioassay sensitivity. In the high miRNA concentration regime(100-10 nM), a significantly increased SERS intensity is detected when the reporters are located closer to the plasmonic surface compared to farther probe labelling positions. Counterintuitively, a levelling-off of the SERS intensity from the two configuration is instead recorded at low miRNA concentration. Such effect is explained by an increased contribution of Raman hot spot to the whole SERS signal, as confirmed by simulations of the electric near field for a simplified model of the Ag nanostructures. The beneficial effect of reducing the reporter-to-surface distance is however partially retained for the two-step hybridization assay thanks to the less sterically hindered environment in which the second hybridization occurs. The study thus demonstrates that the limit of detection of the assay can be lowered by tuning the probe labelling position, but sheds at the same time light on the complexity of the bionanointerfaces in SERS and on the multiple factors affecting bioassay sensitivity.