Researcher profile

Martina F. Callaghan

Martina F. Callaghan contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Universal pulses for homogeneous excitation using single channel coils

Purpose: Universal Pulses (UPs) are excitation pulses that reduce the flip angle inhomogeneity in high field MRI systems without subject-specific optimization, originally developed for parallel transmit (PTX) systems at 7T. We investigated the potential benefits of UPs for single channel (SC) transmit systems at 3T, which are widely used for clinical and research imaging, and for which flip angle inhomogeneity can still be problematic. Methods: SC-UPs were designed using a spiral nonselective k-space trajectory for brain imaging at 3T using transmit field maps (B1+) and off-resonance maps (B0) acquired on two different scanner types: a 'standard' single channel transmit system and a system with a PTX body coil. The effect of training group size was investigated using data (200 subjects) from the standard system. The PTX system was used to compare SC-UPs to PTX-UPs (15 subjects). In two additional subjects, prospective imaging using SC-UP was studied. Results: Average flip angle error fell from 9.5+/-0.5% for 'default' excitation to 3.0+/-0.6% using SC-UPs trained over 50 subjects. Performance of the UPs was found to steadily improve as training group size increased, but stabilized after ~15 subjects. On the PTX-enabled system, SC-UPs again outperformed default excitation in simulations (4.8+/-0.6% error versus 10.6+/-0.8% respectively) though greater homogenization could be achieved with PTX-UPs (3.9+/-0.6%) and personalized pulses (SC-PP 3.6+/-1.0%, PTX-PP 2.9+/-0.6%). MP-RAGE imaging using SC-UP resulted in greater separation between grey and white matter signal intensities than default excitation. Conclusions: SC-UPs can improve excitation homogeneity in standard 3T systems without further calibration and could be used instead of a default excitation pulse for nonselective neuroimaging at 3T.

preprint2020arXiv

Towards in vivo g-ratio mapping using MRI: unifying myelin and diffusion imaging

The g-ratio, quantifying the comparative thickness of the myelin sheath encasing an axon, is a geometrical invariant that has high functional relevance because of its importance in determining neuronal conduction velocity. Advances in MRI data acquisition and signal modelling have put in vivo mapping of the g-ratio, across the entire white matter, within our reach. This capacity would greatly increase our knowledge of the nervous system: how it functions, and how it is impacted by disease. This is the second review on the topic of g-ratio mapping using MRI. As such, it summarizes the most recent developments in the field, while also providing methodological background pertinent to aggregate g-ratio weighted mapping, and discussing pitfalls associated with these approaches. Using simulations based on recently published data, this review demonstrates the relevance of the calibration step for three myelin-markers (macromolecular tissue volume, myelin water fraction, and bound pool fraction). It highlights the need to estimate both the slope and offset of the relationship between these MRI-based markers and the true myelin volume fraction if we are really to achieve the goal of precise, high sensitivity g-ratio mapping in vivo. Other challenges discussed in this review further evidence the need for gold standard measurements of human brain tissue from ex vivo histology. We conclude that the quest to find the most appropriate MRI biomarkers to enable in vivo g-ratio mapping is ongoing, with the potential of many novel techniques yet to be investigated.