Source author record

Mario Mellado

Mario Mellado appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
3topics
2close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2011arXiv

Homogeneity tests for Michaelis-Menten curves with application to fluorescence resonance energy transfer data

Resonance energy transfer methods are in wide use for evaluating protein-protein interactions and protein conformational changes in living cells. Fluorescence resonance energy transfer (FRET) measures energy transfer as a function of the acceptor:donor ratio, generating FRET saturation curves. Modeling these curves by Michaelis-Menten kinetics allows characterization by two parameters, which serve to evaluate apparent affinity between two proteins and to compare this affinity in different experimental conditions. To reduce the effect of sampling variability, several statistical samples of the saturation curve are generated in the same biological conditions. Here we study three procedures to determine whether statistical samples in a collection are homogeneous, in the sense that they are extracted from the same regression model. From the hypothesis testing viewpoint, we considered an F test and a procedure based on bootstrap resampling. The third method analyzed the problem from the model selection viewpoint, and used the Akaike information criterion (AIC). Although we only considered the Michaelis-Menten model, all statistical procedures would be applicable to any other nonlinear regression model. We compared the performance of the homogeneity testing methods in a Monte Carlo study and through analysis in living cells of FRET saturation curves for dimeric complexes of CXCR4, a seven-transmembrane receptor of the G protein-coupled receptor family. We show that the F test, the bootstrap procedure and the model selection method lead in general to similar conclusions, although AIC gave the best results when sample sizes were small, whereas the F test and the bootstrap method were more appropriate for large samples. In practice, all three methods are easy to use simultaneously and show consistency, facilitating conclusions on sample homogeneity.